Christina Georgantopoulou

Prof. Dr. Christina Georgantopoulou


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2016 in Advances in Building Energy Research
Verified
Journal Article
Closed access
PMPayal Modi
Payal Modi
RBRanya Bushehri
Ranya Bushehri
CGChristina Georgantopoulou
Christina Georgantopoulou
Lazaros MAVROMATIDISLazaros MAVROMATIDIS
Lazaros MAVROMATIDIS
Building energy consumption is increasing rapidly, demanding urgent improvement of insulation techniques in order to promote the building’s energy efficiency. The Kingdom of Bahrain presents huge energy demands to the residential buildings due to the continuing air-conditioning units’ operation. Due to this reason, in the present paper, we present the design and development of a modified mini scale hot-box experimental apparatus as well as an experimental and an analytical investigation of the used insulation blocks and techniques in Bahrain, with the aim to measure and evaluate the thermal resistance. The experimental process is developed based on a standardized hot-box design and manufactured with appropriate dimensions, in order to measure the temperature distribution according various climatic conditions. Important results and estimations are produced concerning the thermal resistance of insulation blocks, temperature distribution and heat transfer coefficients. The results are accurate enough and these are validated with the corresponding ones of the literature, through analytical calculations as well as with the manufacturer’s values. It seems that the insulation blocks’ efficiency is adapted to the regional climatic conditions and possible reliable solutions can be applied for further improvement.

1 January 2017 in International Journal of Computing and Digital Systems
Verified
Journal Article
Open access
PDF file
CGChristina Georgantopoulou
Christina Georgantopoulou
NVNikolaos S. Vasilikos
Nikolaos S. Vasilikos
The high electricity demand and consumption of in Gulf Cooperation Council (GCC) countries show that alternative ways of energy production have to be explored and developed. The renewable resources of energy applications should be addressed, tested and evaluated in the GCC region including the solar energy systems approach. In the present paper we identify and present the fundamental parameters for the solar systems installation in GCC, the influence of the local environmental conditions and the panels' characteristics and efficiency for this certain region. An extended investigation is presented concerning the characteristics of the panels' types, the orientation and tilt angle, the influence of dust, humidity and climate temperature and the real efficiency of the panels' estimation. The efficiency and power estimation is analysed by an alternative empirical approach, giving particular interest to the specific factors that are responsible for the efficiency drop. It is concluded that the solar systems application can be high beneficial for the Bahrain region, if the installation is developed according to the specific climate conditions as the dust precedence in the atmosphere or the temperature on the cells during the operation. This type of environmental power production solution can be cost efficient and sustainable, providing to the region an alternative solution for the electricity production.

22 November 2021 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
LGLakshmi Narayana Gollapudi
Lakshmi Narayana Gollapudi
RSRohan Senanayake
Rohan Senanayake
CGChristina Georgantopoulou
Christina Georgantopoulou
ASAnil Kumar Singh
Anil Kumar Singh
Two-dimensional numerical analysis is carried out in a square cavity with extended surface with nanofluid foe heat transfer enhancement under natural convection in a laminar flow regime. Pure water, ethylene glycol (EG), Water/EG mixture (20%, 40%, 60% and 80%) with aluminium oxide concentration of 3% inside a square cavity for a given fin length, position and different Rayleigh number (103, 104, 105, 106) is considered. Numerical analysis is carried out in Ansys Fluent using homogenous heat transfer model. It is observed that as the conductivity ratio and Rayleigh number increased resulting in higher surface temperature leading to heat transfer enhancement. Moreover, a fin position of 0.5 m height and 0.75 m length has been found to be the most optimal position for better heat transfer enhancement. Furthermore, it has been observed that the higher the conductivity ratio of the fin, the better is the heat enhancement.

14 December 2025 in Aerospace
Verified
Journal Article
Open access
PDF file
NGNesrine Gaaliche
Nesrine Gaaliche
CGChristina Georgantopoulou
Christina Georgantopoulou
AAAhmed Mohammed Abdelrhman
Ahmed Mohammed Abdelrhman
RFRaouf Fathallah
Raouf Fathallah
This paper describes a compact low-cost telemetry system featuring ready-made sensors and an acquisition unit based on the ESP32, which makes use of the LoRa/Wi-Fi wireless standard for communication, and autonomous fallback logging to guarantee data recovery during communication loss. Ensuring safe atmospheric re-entry requires reliable onboard monitoring of capsule conditions during descent. The system is intended for sub-orbital, low-cost educational capsules and experimental atmospheric descent missions rather than full orbital re-entry at hypersonic speeds, where the environmental loads and communication constraints differ significantly. The novelty of this work is the development of a fully self-contained telemetry system that ensures continuous monitoring and fallback logging without external infrastructure, bridging the gap in compact solutions for CubeSat-scale capsules. In contrast to existing approaches built around UAVs or radar, the proposed design is entirely self-contained, lightweight, and tailored to CubeSat-class and academic missions, where costs and infrastructure are limited. Ground test validation consisted of vertical drop tests, wind tunnel runs, and hardware-in-the-loop simulations. In addition, high-temperature thermal cycling tests were performed to assess system reliability under rapid temperature transitions between −20 °C and +110 °C, confirming stable operation and data integrity under thermal stress. Results showed over 95% real-time packet success with full data recovery in blackout events, while acceleration profiling confirmed resilience to peak decelerations of ~9 g. To complement telemetry, the TeleCapsNet dataset was introduced, facilitating a CNN recognition of descent states via 87% mean Average Precision, and an F1-score of 0.82, which attests to feasibility under constrained computational power. The novelty of this work is twofold: having reliable dual-path telemetry in real-time with full post-mission recovery and producing a scalable platform that explicitly addresses the lack of compact, infrastructure-independent proposals found in the existing literature. Results show an independent and cost-effective system for small re-entry capsule experimenters with reliable data integrity (without external infrastructure). Future work will explore AI systems deployment as a means to prolong the onboard autonomy, as well as to broaden the applicability of the presented approach into academic and low-resource re- entry investigations.

12 June 2018 in MATEC Web of Conferences
Verified
Journal Article
Open access
CGChristina Georgantopoulou
Christina Georgantopoulou
NVNikolaos S. Vasilikos
Nikolaos S. Vasilikos
GGGeorge A. Georgantopoulos
George A. Georgantopoulos
The recirculation which is developed during the flows inside pipes present a high interest in many industrial applications. In the present paper, a Cartesian grid method is presented which can be applied in pipes geometry approximation, even if the solid bounds are not lying on grid lines. A refinement technique using rectangular nested sub-girds is applied in order to avoid the unnecessary grid cells in the areas with no particular flow interest and cluster the grid when is needed. Important and useful for the industries results are extracted by these numerical simulations and estimations regarding the exact position and extend of the recirculation zones and the relating points. The estimation is taking placefor incompressible laminar, viscous flows inside inclined step channelsfor a range of inclination angles and Reynolds numbers values. The Navier – Stokes equations are solved using the artificial compressibility method according to the necessary boundary conditions arrangement. Flow results are presented for several grid sizes and Reynolds numbers focused on the recirculationzones length, in upper and lower channel’ walls. Accepted accuracy of the flow results is produced using the aforementioned refinement algorithm, while the flow zones can be located according to the inlet flow rate, in order to avoid possible problems in the industries as corrosion or energy losses.

29 October 2024 in Vibration
Verified
Journal Article
Open access
PDF file
Christos ManopoulosChristos Manopoulos
Christos Manopoulos
STSokrates Tsangaris
Sokrates Tsangaris
CGChristina Georgantopoulou
Christina Georgantopoulou
DMDimitrios Mathioulakis
Dimitrios Mathioulakis
This work investigates the conditions for net flow generation by a straight tube with a cross-sectional area harmonically varying in time that connects two tanks—a problem that is mainly found in the design of impedance pumps. By assuming a quasi-one-dimensional flow and applying continuity and momentum equations, a first-order differential equation with respect to the flow rate is derived and presented for the first time, including a nonlinear term that is responsible for net flow rate generation. Namely, the net flow rate is found to be nonzero (as is the nonlinear term) if the cross-sectional areas of the two tanks are unequal and one of them is smaller than that of the straight tube. In this case, the flow is directed from the smaller to the larger tank and the net flow rate increases with the frequency of the tube’s cross-sectional area variation. In contrast, when the tanks’ cross-sections are equal, the net flow is generated only if a valve is installed, e.g., at one end of the tube, due to the large asymmetries imposed in the hydraulic losses with respect to the tube mid-length. Compared with constant valve opening, the net flow rate is augmented significantly if the valve opening is time-dependent. By employing the same equation, the flow rate of an intra-aortic counter-pulsating balloon pump is also examined, in which the valve (representing the aortic valve) opens during the shrinkage of the tube, and it is shown that the net flow rate increases with the frequency and amplitude of the tube’s cross-sectional area. Conclusively, the harmonic oscillation in time of a tube’s wall can cause unidirectional flow only if asymmetric losses are present with respect to its mid-length.