Arnaldo D'Amico

Prof. Arnaldo D'Amico


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 December 2013 in Sensors
Verified
Journal Article
Open access
PDF file
Marco SantonicoMarco Santonico
Marco Santonico
Giorgio PennazzaGiorgio Pennazza
Giorgio Pennazza
SGSimone Grasso
Simone Grasso
ADArnaldo D'Amico
Arnaldo D'Amico
Mariano BizzarriMariano Bizzarri
Mariano Bizzarri
Sensors are often organized in multidimensional systems or networks for particular applications. This is facilitated by the large improvements in the miniaturization process, power consumption reduction and data analysis techniques nowadays possible. Such sensors are frequently organized in multidimensional arrays oriented to the realization of artificial sensorial systems mimicking the mechanisms of human senses. Instruments that make use of these sensors are frequently employed in the fields of medicine and food science. Among them, the so-called electronic nose and tongue are becoming more and more popular. In this paper an innovative multisensorial system based on sensing materials of biological origin is illustrated. Anthocyanins are exploited here as chemical interactive materials for both quartz microbalance (QMB) transducers used as gas sensors and for electrodes used as liquid electrochemical sensors. The optical properties of anthocyanins are well established and widely used, but they have never been exploited as sensing materials for both gas and liquid sensors in non-optical applications. By using the same set of selected anthocyanins an integrated system has been realized, which includes a gas sensor array based on QMB and a sensor array for liquids made up of suitable Ion Sensitive Electrodes (ISEs). The arrays are also monitored from an optical point of view. This embedded system, is intended to mimic the working principles of the nose, tongue and eyes. We call this setup BIONOTE (for BIOsensor-based multisensorial system for mimicking NOse, Tongue and Eyes). The complete design, fabrication and calibration processes of the BIONOTE system are described herein, and a number of preliminary results are discussed. These results are relative to: (a) the characterization of the optical properties of the tested materials; (b) the performance of the whole system as gas sensor array with respect to ethanol, hexane and isopropyl alcohol detection (concentration range 0.1–7 ppm) and as a liquid sensor array (concentration range 73–98 μM).

24 April 2012 in Expert Opinion on Medical Diagnostics
Verified
Journal Article
Closed access
ADArnaldo D'Amico
Arnaldo D'Amico
Corrado Di NataleCorrado Di Natale
Corrado Di Natale
CFChristian Falconi
Christian Falconi
EMEugenio Martinelli
Eugenio Martinelli
Roberto PaolesseRoberto Paolesse
Roberto Paolesse
PSPeter Jason Sterk
Peter Jason Sterk
(2012). Detection and identification of cancers by the electronic nose. Expert Opinion on Medical Diagnostics: Vol. 6, No. 3, pp. 175-185. doi: 10.1517/17530059.2012.665870

28 October 2017 in Sensors
Verified
Journal Article
Open access
PDF file
FPFrancesca Romana Parente
Francesca Romana Parente
Marco SantonicoMarco Santonico
Marco Santonico
Alessandro ZompantiAlessandro Zompanti
Alessandro Zompanti
MBMario Benassai
Mario Benassai
Giuseppe FerriGiuseppe Ferri
Giuseppe Ferri
Giorgio PennazzaGiorgio Pennazza
Giorgio Pennazza
The aim of this work is the development of a contactless capacitive sensory system for the detection of (Electrocardiographic) ECG-like signals. The acquisition approach is based on a capacitive coupling with the patient body performed by electrodes integrated in a front-end circuit. The proposed system is able to detect changes in the electric charge related to the heart activity. Due to the target signal weakness and to the presence of other undesired signals, suitable amplification stages and analogue filters are required. Simulated results allowed us to evaluate the effectiveness of the approach, whereas experimental measurements, recorded without contact to the skin, have validated the practical effectiveness of the proposed architecture. The system operates with a supply voltage of ±9 V with an overall power consumption of about 10 mW. The analogue output of the electronic interface is connected to an ATmega328 microcontroller implementing the A/D conversion and the data acquisition. The collected data can be displayed on any multimedia support for real-time tracking applications.

1 May 2007
Verified
Conference Paper
Closed access
Christian FalconiChristian Falconi
Christian Falconi
ADArnaldo D'Amico
Arnaldo D'Amico
Giuseppe ScottiGiuseppe Scotti
Giuseppe Scotti
ATAlessandro Trifiletti
Alessandro Trifiletti
The authors describe low voltage current and voltage references which only use MOSFETs in strong inversion and pnp substrate transistors; both the references exhibit very good performance in terms of power supply rejection and do not require compensation capacitances; the minimum supply voltage is about 0.8V for the current reference and 1.2V for the voltage reference.

28 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
TSTommaso Schirinzi
Tommaso Schirinzi
ACAlberto Cordella
Alberto Cordella
Nicola Biagio MercuriNicola Biagio Mercuri
Nicola Biagio Mercuri
ADArnaldo D'Amico
Arnaldo D'Amico
APAndrea Palombi
Andrea Palombi
Marco SantonicoMarco Santonico
Marco Santonico
Cerebrospinal fluid (CSF) analysis supports diagnosis of neurodegenerative diseases (NDs), however a number of issues limits its potentialities in clinical practice. Here, a newly developed technique for fluid voltammetry, relying on a simple sensor (BIOsensor-based multisensorial system for mimicking Nose, Tongue and Eyes, BIONOTE), was used to test the applicability for CSF analysis. BIONOTE was initially calibrated on an artificial CSF-like solution and then applied on human CSF, either immediately after collection or after refrigerated storage. Following optimization, it was used to evaluate 11 CSF samples correlating the electrochemical dataset with CSF routine parameters and biomarkers of neurodegeneration. Multivariate data analysis was performed for model elaboration and calibration using principal component analysis and partial least squares discriminant analysis. BIONOTE presented a high capacity to predict both physiological and pathological constituents of artificial CSF. It differentiated distinct fresh human CSF samples well but lost accuracy after refrigerated storage. The electrochemical analysis-derived data correlated with either CSF routine cytochemical indexes or a biomarker of neurodegeneration. BIONOTE resulted as being a reliable system for electrochemical analysis of CSF. The CSF fingerprint provided by the sensor has shown itself to be sensitive to CSF modification, thus it is potentially representative of CSF alteration. This result opens the way to its testing in further study addressed at assessing the clinical relevance of the methodology. Because of its advantages due to the ease and rapidity of the methodology, a validation study is now required to translate the technique into clinical practice and improve diagnostic workup of NDs.

11 August 2017 in Proceedings
Verified
Conference Paper
Open access
PDF file
Marco SantonicoMarco Santonico
Marco Santonico
Giorgio PennazzaGiorgio Pennazza
Giorgio Pennazza
FPFrancesca Romana Parente
Francesca Romana Parente
SGSimone Grasso
Simone Grasso
Alessandro ZompantiAlessandro Zompanti
Alessandro Zompanti
ADArnaldo D'Amico
Arnaldo D'Amico
Sensors for monitoring oxygen and carbon dioxide are crucial as investigational devices in many different research fields, including environmental, biomedical and industrial. They must be easily configurable, fast responding, and with good reproducibility and sensitivity. The state of art reports different sensing and transducing strategies: electrochemical, optical, conductometric etc., based on specific chemically interactive materials. In this work, a multisensor system based on electrochemical sensors acting via a liquid medium and controlled by a dedicated low-noise electronic interface is equipped with an elaboration unit able in extracting/storing a committed model for oxygen and carbon dioxide detection.