Marco Endrizzi

Dr. Marco Endrizzi

Department of Medical Physics and Biomedical Engineering, University College London, Gower St, London WC1E 6BT, UK
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
Marco EndrizziMarco Endrizzi
Marco Endrizzi

13 January 2014 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
Marco EndrizziMarco Endrizzi
Marco Endrizzi
PDPaul C. Diemoz
Paul C. Diemoz
TMThomas P. Millard
Thomas P. Millard
JJJ. Louise Jones
J. Louise Jones
RSRobert D. Speller
Robert D. Speller
AOAlessandro Olivo
Alessandro Olivo
We report on a non-interferometric technique enabling dark-field imaging by using incoherent illumination and two achromatic optical elements. The simultaneous retrieval of absorption and differential phase images in the hard X-ray regime is also provided. We show that three projection images are sufficient to separate three signals: absorption, differential phase, and scattering. The method is highly efficient, also in terms of the dose delivered to the sample, flexible, robust against environmental vibrations, and scalable. It can be easily implemented in laboratories and translated into commercial systems, lending itself to a wide range of applications.

7 August 2013 in Medical Physics
Verified
Journal Article
Closed access
AOAlessandro Olivo
Alessandro Olivo
SGS. Gkoumas
S. Gkoumas
Marco EndrizziMarco Endrizzi
Marco Endrizzi
CHC. K. Hagen
C. K. Hagen
MSM. B. Szafraniec
M. B. Szafraniec
RSR. D. Speller
R. D. Speller

1 June 2015 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
FVFabio A. Vittoria
Fabio A. Vittoria
GKGibril K. N. Kallon
Gibril K. N. Kallon
DBDario Basta
Dario Basta
PDPaul C. Diemoz
Paul C. Diemoz
IRIan Robinson
Ian Robinson
Marco EndrizziMarco Endrizzi
Marco Endrizzi
We present the translation of the beam tracking approach for x–ray phase–contrast and dark–field imaging, recently demonstrated using synchrotron radiation, to a laboratory setup. A single absorbing mask is used before the sample, and a local Gaussian interpolation of the beam at the detector is used to extract absorption, refraction, and dark–field signals from a single exposure of the sample. Multiple exposures can be acquired when high resolution is needed, as shown here. A theoretical analysis of the effect of polychromaticity on the retrieved signals, and of the artifacts this might cause when existing retrieval methods are used, is also discussed.

24 June 2014 in Medical Physics
Verified
Journal Article
Open access
CHC. K. Hagen
C. K. Hagen
PMPeter Munro
Peter Munro
Marco EndrizziMarco Endrizzi
Marco Endrizzi
PDP. C. Diemoz
P. C. Diemoz
AOAlessandro Olivo
Alessandro Olivo
The edge illumination (EI) x-ray phase contrast imaging (XPCi) method has been recently further developed to perform tomographic and, thus, volumetric imaging. In this paper, the first tomographic EI XPCi images acquired with a conventional x-ray source at dose levels below that used for preclinical small animal imaging are presented. Two test objects, a biological sample and a custom-built phantom, were imaged with a laboratory-based EI XPCi setup in tomography mode. Tomographic maps that show the phase shift and attenuating properties of the object were reconstructed, and analyzed in terms of signal-to-noise ratio and quantitative accuracy. Dose measurements using thermoluminescence devices were performed. The obtained images demonstrate that phase based imaging methods can provide superior results compared to attenuation based modalities for weakly attenuating samples also in 3D. Moreover, and, most importantly, they demonstrate the feasibility of low-dose imaging. In addition, the experimental results can be considered quantitative within the constraints imposed by polychromaticity. The results, together with the method's dose efficiency and compatibility with conventional x-ray sources, indicate that tomographic EI XPCi can become an important tool for the routine imaging of biomedical samples.

28 March 2013 in Physical Review Letters
Verified
Journal Article
Closed access
PDP. C. Diemoz
P. C. Diemoz
Marco EndrizziMarco Endrizzi
Marco Endrizzi
CZC. E. Zapata
C. E. Zapata
ZPZ. D. Pešić
Z. D. Pešić
CRC. Rau
C. Rau
AOAlessandro Olivo
Alessandro Olivo
We present a new quantitative x-ray phase-contrast imaging method based on the edge illumination principle, which allows achieving unprecedented nanoradian sensitivity. The extremely high angular resolution is demonstrated theoretically and through experimental images obtained at two different synchrotron radiation facilities. The results, achieved at both very high and very low x-ray energies, show that this highly sensitive technique can be efficiently exploited over a very broad range of experimental conditions. This method can open the way to new, previously inaccessible scientific applications in various fields including biology, medicine and materials science.