Representative Publications

View All Publications
13 January 2014 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
Marco EndrizziMarco Endrizzi
Marco Endrizzi
PDPaul C. Diemoz
Paul C. Diemoz
TMThomas P. Millard
Thomas P. Millard
JJJ. Louise Jones
J. Louise Jones
RSRobert D. Speller
Robert D. Speller
AOAlessandro Olivo
Alessandro Olivo
We report on a non-interferometric technique enabling dark-field imaging by using incoherent illumination and two achromatic optical elements. The simultaneous retrieval of absorption and differential phase images in the hard X-ray regime is also provided. We show that three projection images are sufficient to separate three signals: absorption, differential phase, and scattering. The method is highly efficient, also in terms of the dose delivered to the sample, flexible, robust against environmental vibrations, and scalable. It can be easily implemented in laboratories and translated into commercial systems, lending itself to a wide range of applications.

1 August 2013 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
TMT. P. Millard
T. P. Millard
Marco EndrizziMarco Endrizzi
Marco Endrizzi
KIK. Ignatyev
K. Ignatyev
CHC. K. Hagen
C. K. Hagen
PMPeter Munro
Peter Munro
AOAlessandro Olivo
Alessandro Olivo
Here we present a general alignment algorithm for an edge illumination x-ray phase contrast imaging system, which is used with the laboratory systems developed at UCL. It has the flexibility to be used with all current mask designs, and could also be applied to future synchrotron based systems. The algorithm has proved to be robust experimentally, and can be used for the automatization of future commercial systems through automatic alignment and alignment correction.

29 July 2015 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TMT. P. Millard
T. P. Millard
Marco EndrizziMarco Endrizzi
Marco Endrizzi
NEN. Everdell
N. Everdell
LRL. Rigon
L. Rigon
FAF. Arfelli
F. Arfelli
AOAlessandro Olivo
Alessandro Olivo
X-rays are commonly used as a means to image the inside of objects opaque to visible light, as their short wavelength allows penetration through matter and the formation of high spatial resolution images. This physical effect has found particular importance in medicine where x-ray based imaging is routinely used as a diagnostic tool. Increasingly, however, imaging modalities that provide functional as well as morphological information are required. In this study the potential to use x-ray phase based imaging as a functional modality through the use of microbubbles that can be targeted to specific biological processes is explored. We show that the concentration of a microbubble suspension can be monitored quantitatively whilst in flow using x-ray phase contrast imaging. This could provide the basis for a dynamic imaging technique that combines the tissue penetration, spatial resolution and high contrast of x-ray phase based imaging with the functional information offered by targeted imaging modalities.

9 September 2013 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
TMT. P. Millard
T. P. Millard
Marco EndrizziMarco Endrizzi
Marco Endrizzi
LRL. Rigon
L. Rigon
FAF. Arfelli
F. Arfelli
RMRalf Hendrik Menk
Ralf Hendrik Menk
AOAlessandro Olivo
Alessandro Olivo
The use of microbubbles as a contrast agent for x-ray phase contrast imaging could both transform x-ray imaging into a “functional” modality and enable much needed monitoring of targeted drug delivery. To realize these benefits, it is essential to be able to quantify bubble concentration in a given tissue volume. We developed and validated a model that enables this to be achieved not only for phase-retrieved images obtained by processing multiple frames but also on “single-shot” images, a likely necessity in in-vivo implementations. Our experimental validation was based on analyzer-based imaging, but extension to other phase-based modalities is straightforward.

1 May 2014 in Review of Scientific Instruments
Verified
Journal Article
Closed access
TMT. P. Millard
T. P. Millard
Marco EndrizziMarco Endrizzi
Marco Endrizzi
PDP. C. Diemoz
P. C. Diemoz
CHC. K. Hagen
C. K. Hagen
AOAlessandro Olivo
Alessandro Olivo
A Monte Carlo model of a polychromatic laboratory based (coded aperture) edge illumination x-ray phase contrast imaging system has been developed and validated against experimental data. The ability for the simulation framework to be used to model two-dimensional images is also shown. The Monte Carlo model has been developed using the McXtrace engine and is polychromatic, i.e., results are obtained through the use of the full x-ray spectrum rather than an effective energy. This type of simulation can in future be used to model imaging of objects with complex geometry, for system prototyping, as well as providing a first step towards the development of a simulation for modelling dose delivery as a part of translating the imaging technique for use in clinical environments.

20 February 2014 in Physics in Medicine & Biology
Verified
Journal Article
Open access
MSMagdalena B Szafraniec
Magdalena B Szafraniec
TMThomas P Millard
Thomas P Millard
KIKonstantin Ignatyev
Konstantin Ignatyev
RSRobert D Speller
Robert D Speller
AOAlessandro Olivo
Alessandro Olivo
In this note we present the first proof-of-concept results on the potential effectiveness of the edge-illumination x-ray phase contrast method (in its 'coded-aperture' based lab implementation) combined with tomosynthesis. We believe that, albeit admittedly preliminary (e.g. we only present phantom work), these results deserve early publication in a note primarily for four reasons. First, we fully modelled the imaging acquisition method, and validated the simulation directly with experimental results. This shows that the implementation of the method in the new geometry is understood, and thus that it will be possible to use the model to simulate more complex scenarios in the future. Secondly, we show that a strong phase contrast signal is preserved in the reconstructed tomosynthesis slices: this was a concern, as the high spatial frequency nature of the signal makes it sensitive to any filtration-related procedure. Third, we show that, despite the non-optimized nature of the imaging prototype used, we can perform a full angular scan at acceptable dose levels and with exposure times not excessively distant from what is required by clinical practice. Finally, we discuss how the proposed phase contrast method, unlike other approaches apart from free-space propagation (which however requires a smaller focal spot, thus reducing the flux and increasing exposure times), can be easily implemented in a tomosynthesis geometry suitable for clinical use. In summary, we find that these technical results indicate a high potential for the combination of the two methods. Combining slice separation with detail enhancement provided by phase effects would substantially increase the detectability of small lesions and/or calcifications, which we aim to demonstrate in the next steps of this study.