Mammography is the primary imaging tool for screening and diagnosis of human breast cancers, but ∼10–20% of palpable tumors are not detectable on mammograms and only about 40% of biopsied lesions are malignant. Here we report a high-resolution, low-dose phase contrast X-ray tomographic method for 3D diagnosis of human breast cancers. By combining phase contrast X-ray imaging with an image reconstruction method known as equally sloped tomography, we imaged a human breast in three dimensions and identified a malignant cancer with a pixel size of 92 μm and a radiation dose less than that of dual-view mammography. According to a blind evaluation by five independent radiologists, our method can reduce the radiation dose and acquisition time by ∼74% relative to conventional phase contrast X-ray tomography, while maintaining high image resolution and image contrast. These results demonstrate that high-resolution 3D diagnostic imaging of human breast cancers can, in principle, be performed at clinical compatible doses.
We report on a non-interferometric technique enabling dark-field imaging by using incoherent illumination and two achromatic optical elements. The simultaneous retrieval of absorption and differential phase images in the hard X-ray regime is also provided. We show that three projection images are sufficient to separate three signals: absorption, differential phase, and scattering. The method is highly efficient, also in terms of the dose delivered to the sample, flexible, robust against environmental vibrations, and scalable. It can be easily implemented in laboratories and translated into commercial systems, lending itself to a wide range of applications.
Various X-ray phase-contrast imaging techniques have been developed and applied over the last twenty years in different domains, such as material sciences, biology and medicine. However, no comprehensive inter-comparison exists in the literature. We present here a theoretical study that compares three among the most used techniques: propagation-based imaging (PBI), analyzer-based imaging (ABI) and grating interferometry (GI). These techniques are evaluated in terms of signal-to-noise ratio, figure of merit and spatial resolution. Both area and edge signals are considered. Dependences upon the object properties (absorption, phase shift) and the experimental acquisition parameters (energy, system point-spread function etc.) are derived and discussed. The results obtained from this analysis can be used as the reference for determining the most suitable technique for a given application.
We present the translation of the beam tracking approach for x–ray phase–contrast and dark–field imaging, recently demonstrated using synchrotron radiation, to a laboratory setup. A single absorbing mask is used before the sample, and a local Gaussian interpolation of the beam at the detector is used to extract absorption, refraction, and dark–field signals from a single exposure of the sample. Multiple exposures can be acquired when high resolution is needed, as shown here. A theoretical analysis of the effect of polychromaticity on the retrieved signals, and of the artifacts this might cause when existing retrieval methods are used, is also discussed.
We analyze the spatial resolution of edge illumination X-ray phase-contrast imaging and its dependence upon various experimental parameters such as source size, source-to-sample and sample-to-detector distances, X-ray energy and size of the beam-shaping aperture. Different propagation regimes, as well as the beam divergence and polychromaticity encountered with laboratory sources, are also considered. We show that spatial resolution in edge illumination phase-contrast imaging presents peculiar features compared to other X-ray phase-contrast techniques. In particular, in the direction orthogonal to the s or mask lines used to shape the beam, this can be better than both the pixel dimension and the projected source size. Numerical simulations based on Fresnel diffraction integrals are presented, which confirm the analytical predictions. The obtained results allow a simple estimation of the spatial resolution for edge-illumination phase imaging in both synchrotron and laboratory setups.