Axial flow fans are used in many fields in order to ensure the mass and heat transfer from air, chiefly in the heating, ventilation and air conditioning industry (HVAC). A more proper understanding of the airflow behavior through the systems is necessary to manage and optimize the fan operation. Computational fluid dynamics (CFD) represents a real tool providing the ability to access flow structures in areas that measuring equipment cannot reach. Reducing the leakage flow rate, inherent in operation, by synthetic-jet techniques improves performance. This paper presents the CFD results performed on a hollow blade fan developed by our team. The leakage flow is controlled by blowing air from 16 designated circular holes and arranged on the fan shroud. We discuss the results for two rotational speeds (1000 and 2000 rpm) and two injection rates (400 and 800 L/min). The numerical results consistent with the experimental show, for the low rotation speed and high injection ratio, significant gains in power (53%), torque (80%) and leakage flow rate (80%).
10 September 2014 in Journal of Fluids Engineering
In the current paper, the three-dimensional air flow evolution around a circular cylinder is studied. The main aim is to control the flow field upstream and downstream of a circular cylinder by means of radial deformation. Within a particular step, one focuses on the response of the topological structures, which is developing in the cylinder near wake to applied pulsatile motion. Furthermore, a special care is considered to the aerodynamics forces behavior in adjusting the applied controlling strategy. The used controlling frequency range extends from f = 1fn = 17 Hz to f = 6fn = 102.21 Hz, which corresponds to a series of multiharmonic frequency varying from one to six times the natural vortex shedding frequency (VSF) in none forced wake. Throughout this work, the forcing amplitude is fixed at 16% of cylinder diameter and the Reynolds number as Re = 550. Through Fluent computational fluid dynamics (CFD) code and Matlab simulations, the obtained results showed a good accordance with the calculated ones.
A numerical study of a controlled flow evolving in a Taylor-Couette system is presented in this paper. The study is devoted to investigate the effect of the outer cylinder cross-section variation on the flow behavior. It is aimed to make assessment of the flow response in terms of the criticality of the early transitional flow regimes and the accompanying flow topology alterations. The numerical simulations are carried out on the Fluent software package for a three-dimensional incompressible flow. The basic system is characterized by a height H = 200 mm, a ratio of the inner to the outer cylinders radii η = 0.9, an aspect ratio corresponding to the cylinders height reported to the gap length Г = 40 and a ratio of the gap to the radius of the inner cylinder δ = 0.1. The numerical deformation of the outer cylinder is executed using the dynamic mesh program according to a predefined function implemented in a homemade program as an UDF (user defined function). It is established that the first instability mode of transition is retarded from Tac1 = 41.33, corresponding to the first Taylor number critical value, to Tac1 = 70 when the deforming amplitude is equal to 15% the external cylinder diameter value. This flow relaminarization process is accompanied by substantial modifications in the flow behavior and configuration.
20 April 2021 in Journal of the Brazilian Society of Mechanical Sciences and Engineering