CHIEMEKA LOVETH MAXWELL

Dr. CHIEMEKA LOVETH MAXWELL

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MYMU YANG
MU YANG
XWXIAOJIE WU
XIAOJIE WU
CMCHIEMEKA LOVETH MAXWELL
CHIEMEKA LOVETH MAXWELL
The deep reinforcement learning (DRL) technique has gained attention for its potential in designing “virtual network” controllers. This skill utilizes a novel solution that can avoid the specific parameters and system model required in classical dynamic programming algorithms. However, addressing the issue of system uncertainties and performance deterioration remains a challenge. To overcome this challenge, the authors propose a new control prototype using a twin delayed deep deterministic policy gradient (TD3)-based adaptive controller, which replaces the conventional virtual synchronous generator (VSG) module in the modular multilevel converter (MMC) control. In this approach, an adaptive programming module is developed using a critic fuzzy network point of view to determine the optimal control policy. The modification presented in this framework is able to improve the system stability and resist disruptions while retaining the merits of the conventional VSG control model. The proposed approach is implemented and tested using the DRL toolbox in MATLAB/Simulink.

21 September 2024 in Energies
Verified
Journal Article
Open access
PDF file
MYMU YANG
MU YANG
XWXIAOJIE WU
XIAOJIE WU
Dongsheng YuDongsheng Yu
Dongsheng Yu
CMCHIEMEKA LOVETH MAXWELL
CHIEMEKA LOVETH MAXWELL
SYSamson Shenglong Yu
Samson Shenglong Yu
Modular Multilevel Converter Virtual Synchronous Generator (MMC-VSG) technology is gaining widespread attention for its ability to enhance the inertia and frequency stability of the power grid integrated with converter-interfaced renewable energy sources. However, the excitation voltage regulation in the MMC-VSG can generate equivalent negative damping torque and cause low-frequency oscillation problems similar to those in synchronous machines. This article aims to improve the system’s damping torque and minimize low-frequency oscillations by introducing a Virtual Power System Stabilizer (VPSS) into the power control loop. Building on the study of dynamic interactions between various control links of the MMC, this research establishes a reduced-order model (ROM) and a Phillips–Heffron state equation for the MMC-VSG single machine infinite bus system, using a hybrid modeling approach and a zero-pole truncation method. It also analyzes the mechanism of low-frequency oscillations in the MMC-VSG system through the damping torque method. The analysis reveals that the negative damping torque produced during the excitation voltage regulation process causes changes in the virtual power angle, which in turn increases the risk of low-frequency oscillation in the MMC-VSG. To address this issue, the article proposes an optimized control method for the MMC-VSG dual power loop architecture (power-angle/excitation) VPSS. This strategy compensates for the inadequate damping torque of a single loop VPSS and effectively suppresses low-frequency oscillations in the system.

26 November 2024 in IET Power Electronics
Verified
Journal Article
Open access
CMCHIEMEKA LOVETH MAXWELL
CHIEMEKA LOVETH MAXWELL
ZWZixiang Wang
Zixiang Wang
Dongsheng YuDongsheng Yu
Dongsheng Yu
MPMarek Pastor
Marek Pastor
SYSamson Shenglong Yu
Samson Shenglong Yu
MAMohammed Alkahtani
Mohammed Alkahtani
In power and data synchronous transmission (PDST), it is crucial to modulate additional signals onto the voltage bus of the converters. This reduces the cost of monitoring and control of the power grid. There is thus the need to ensure that the data transmitted is well secured. This study, designs an electronic system that uses the common coupling point for PDST. Then Chua's memristive circuit is introduced as an entropy source for generating a random bit sequence for encrypted PDST in a switched mode power supply. The encrypted data signal is modulated using phase shift key modulation. Thereafter, the carrier signal is pulse width modulation modulated to control the switching operation of the power switch. The use of Chua's memristive circuit for generating a random number is not new; however, there is little study directly adopting its use in PDST. This allows for resource sharing since multiple signal sources can share the same bus without interference or security risk. The generated random bits are tested for randomness using National Institute of Standards and Technology test suite and autocorrelation test. MATLAB/Simulink and experimental results both confirm the effectiveness of the proposed data encryption method.

12 June 2025 in Electrical Engineering
Verified
Journal Article
Open access
PDF file
MPMarek Pástor
Marek Pástor
DGDaniel Gordan
Daniel Gordan
CMCHIEMEKA LOVETH MAXWELL
CHIEMEKA LOVETH MAXWELL
The phase-shifted full-bridge (PSFB) converter is a preferred topology for isolated DC-DC converters with medium to high power levels. It can be utilized in a variety of applications, preferably with a wide input and/or output range. The efficiency of the converter, as well as its power density, is important factors for modern applications in the automotive industry or renewable energy sources. New semiconductor components based on gallium-nitride (GaN), silicon-carbide, or older silicon MOSFETs, specially designed for resonant converters, together with suitable converter modifications, enable an increase in efficiency and switching frequency. Various auxiliary networks and snubbers extended the limited zero-voltage switching (ZVS) in the lagging leg of the converter. GaN FET enables the utilization of small output capacitances in the PSFB converter to achieve ZVS at low loads even without auxiliary circuits. The small R DS(on) enables the decrease of the conduction losses caused by the circulating current. The FB converter with a controlled rectifier and secondary side energy recovery snubber and the PSFB converter with a synchronous rectifier are compared by simulation for different operational conditions. Finally, a measurement is performed on a PSFB converter with a synchronous rectifier at reduced output power, using a different output rectifier as mentioned in the theoretical part. The experimental part highlights the partial or full achievement of ZVS at different load currents.

31 October 2025 in International Journal of Bifurcation and Chaos
Verified
Journal Article
Closed access
CMCHIEMEKA LOVETH MAXWELL
CHIEMEKA LOVETH MAXWELL
Dongsheng YuDongsheng Yu
Dongsheng Yu
SYSamson Shenglong Yu
Samson Shenglong Yu

25 November 2025 in Computers and Electrical Engineering
Verified
Journal Article
Closed access
CMCHIEMEKA LOVETH MAXWELL
CHIEMEKA LOVETH MAXWELL
DYDongsheng Yu
Dongsheng Yu
YLYang Leng
Yang Leng