Levente Sándor

Mr. Levente Sándor

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2025 in Powder Technology
Verified
Journal Article
Open access
ÁOÁlmos Orosz
Álmos Orosz
LSLevente Sándor
Levente Sándor
KFKhadijeh Firoozirad
Khadijeh Firoozirad
ÉPÉva Pusztai
Éva Pusztai
PNPeter Nagy-Gyorgy
Peter Nagy-Gyorgy
BSBotond Szilagyi
Botond Szilagyi

3 August 2023 in Ultrasonics Sonochemistry
Verified
Journal Article
Open access
PKPéter Kalmár
Péter Kalmár
FHFerenc Hegedűs
Ferenc Hegedűs
DNDániel Nagy
Dániel Nagy
LSLevente Sándor
Levente Sándor
KKKálmán Klapcsik
Kálmán Klapcsik
A fixed-point iteration technique is presented to handle the implicit nature of the governing equations of nonlinear surface mode oscillations of acoustically excited microbubbles. The model is adopted from the theoretical work of Shaw [1], where the dynamics of the mean bubble radius and the surface modes are bi-directionally coupled via nonlinear terms. The model comprises a set of second-order ordinary differential equations. It extends the classic Keller-Miksis equation and the linearized dynamical equations for each surface mode. Only the implicit parts (containing the second derivatives) are reevaluated during the iteration process. The performance of the technique is tested at various parameter combinations. The majority of the test cases needs only a single reevaluation to achieve 10-9 error. Although the arithmetic operation count is higher than the Gauss elimination, due to its memory-friendly matrix-free nature, it is a viable alternative for high-performance GPU computations of massive parameter studies.

25 May 2023 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
LSLevente Sándor
Levente Sándor
GPGyörgy Paál
György Paál
Intracranial aneurysms are nowadays treated with endovascular flow diverter devices to avoid sac rupture. This study explores how different linear and quadratic hydrodynamic resistance parameters reduce the flow in the sac for five patient-specific sidewall aneurysms.The 125 performed blood flow simulations included the stents using a Darcy-Forcheimer porous layer approach based on real-life stent characteristics. Time- and space-averaged velocity magnitudes were strongly affected by the linear coefficient with a power-law relationship. Quadratic coefficients alter the flow in a minor way due to the low-velocity levels in the aneurysm sac and neck region.

10 September 2024 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
RWRichárd Wéber
Richárd Wéber
LSLevente Sándor
Levente Sándor
ÁHÁkos Horváth
Ákos Horváth
GBGábor Barakka
Gábor Barakka
GAG R Abhijith
G R Abhijith
Avi OstfeldAvi Ostfeld
Avi Ostfeld
High-quality drinking water is an essential need of every modern settlement. Typical analysis applies the EPANET to calculate the water age and the chlorine distribution. However, it cannot cope with diffusion or three-dimensional effects. This study aims to find the potential cases where the traditional modelling needs adjustment or improvements. This study uses computational fluid dynamics to analyse how non-reacting contaminants (e.g., fluoride, chloride, metal oxides, and micropollutants) spread in water distribution networks.

30 April 2026 in Journal of Biomechanics
Verified
Journal Article
Open access
LSLevente Sándor
Levente Sándor
BBBenjamin Benjamin
Benjamin Benjamin
GPGyörgy Paál
György Paál
Today, flow diverters (FDs) are commonly used in treating intracranial aneurysms to occlude the sac, thus reconstructing the parent artery. Modeling the effect of FD is challenging but a porous layer approximation in hemodynamic analysis can balance computational efficiency, while maintaining physiological precision. However, the porous FD model requires linear and quadratic coefficients of the pressure drop, which can be obtained from hydrodynamic resistance (HR) measurements. These measurements are difficult to carry out even in a laboratory environment. This article presents an in vitro measurement and data correction technique to acquire the properties and present simulation-ready coefficients incorporated into a numerical in-silico solution based on the lattice-Boltzmann method (LBM). In order to examine post-treatment hemodynamics in patient-specific aneurysm models, these improved HR coefficients were integrated into our computational fluid dynamics (CFD) solver. A test case demonstrates the potential of this strategy by showing, how the deployment of FDs reduces intra-aneurysmal flow. The methodology prepares the ground for future research on more reliable FD characterization by increasing the predictive accuracy of FD simulations.