The load cell is an indispensable component of many engineering machinery and industrial automation for measuring and sensing force and torque. In this paper, we propose to investigate a force sensor design combining Surface Acoustic Wave (SAW) strain sensor with binocular load cell structure. For this purpose, we use a binocular test body instrumented with both resistive strain gauge as a reference and SAW strain sensor. The system enables the generation of extremely localized and accurate positive and negative strains. Static and dynamic measurements are performed using calibrated weights and a shock hammer respectively. For SAW sensor, a one-port resonator with frequency operation in the range of 410MHz was fabricated and mounted on the test body. For electronic conditioning, we use a low-cost RF electronic conditioning based on radar architecture using the integrated circuit AD8302. The system enables the measurement of S 11 reflection coefficient (module and phase) with sensitivity and noise spectral density of (29 mV/dB, 250 nV/√Hz) and (10 mV/°, 83 nV/√Hz) respectively. The SAW sensor mounted on body proof was successfully tested in static and dynamic mode using this electronic architecture. The results show good linearity, sensitivity values of 0.023 mV/ppm and 0.09 mV/ppm were obtained for amplitude and phase measurements respectively. The dynamic response was performed using a shock hammer and a comparison with conventional strain gauge shows a good agreement.
In this study, we conduct a comprehensive investigation to enhance the performance of shear surface acoustic wave (SAW) magnetic sensors. We explore the interaction between SAW and a nickel film deposited on ST-cut quartz in a delay line configuration. The nickel film, measuring 2 mm in width and 100 nm in thickness, undergoes vacuum annealing at 500 C to induce magnetic anisotropy through the anisotropic thermal properties of ST-cut quartz. Our research combines theoretical and experimental approaches to evaluate the S21 phase shift in response to an applied magnetic field. The results demonstrate a remarkable agreement between theoretical predictions and experimental data. To interpret the sensor's response behavior, we introduce a custom piezomagnetic model. Notably, we observe a phase shift difference between minimum and maximum of approximately 30 for a propagation path of 2 mm . We further investigate the impact of incorporating an SiO2 layer on top of the magnetic thin film. This addition doubles the phase shift difference, as shear SAWs become more confined near the surface or entirely waveguided within the SiO2 layer. Additionally, we explore an innovative approach for modifying the sensor's response behavior by manipulating the magnetic thin film's anisotropy. These findings contribute to the advancement of SAW magnetic sensor technology, offering enhanced sensitivity and performance through the integration of magnetic thin films and SiO2 layers.
Surface Acoustic Wave (SAW) sensors represent a prominent technological avenue for quantifying mechanical stress-induced deformations. Nonetheless, the integration of these Micro-Electro-Mechanical Systems (MEMS) sensors remains an complex challenge. Consequently, a common approach within a multitude of research involves the utilization of a adhesive formulation. However, this mode of integration continues to exhibit deficiencies in terms of measurement repeatability, particularly when confronted with harsh environments characterized by pronounced mechanical and thermal stresses. In this context, the utilization of backside reflow soldering for SAW sensor integration stands as a notably dependable alternative to epoxy bonding. In this article, we present the results of our feasibility study concerning the reflow soldering of a SAW sensor onto a binocular copper load cell to measure static strains and a ferromagnetic steel sheet to measure dynamic strains resulting from magnetostriction. To use reflow soldering, a nickel/copper electrodeposition on the ferromagnetic steel sheet was carried out, demonstrating the potential to apply this technique to various materials. The results have indicated that reflow soldering enhances the transmission of static and dynamic mechanical stresses to the SAW sensor, exhibiting a coefficient threefold greater than that achieved through simple adhesive bonding. Furthermore, this integration technique demonstrated a long-term stability of the measurement.
High-power electrical machines often utilize clamping structures composed of various materials with specific geometric dimensions to secure the stator laminations. These structures are exposed to end-region magnetic flux, which induces eddy currents, leading to significant power losses that reduce the machine’s efficiency. This study systematically investigates the impact of clamping plate thickness on eddy current losses across different materials and operating frequencies. A simplified experimental configuration was established to validate the numerical model developed using 3D Finite Element Method (FEM). This model was used to calculate the eddy current losses and analyze the influence of plate thickness under various conditions. A comprehensive parametric analysis was performed, revealing critical insights into the relationship between material properties, plate thickness, and loss generation. The findings indicate that while thinner plates exhibit higher current density, thicker plates provide a larger volume for current flow, resulting in varying loss patterns depending on the material’s electrical and magnetic properties. The study’s results offer valuable guidance for optimizing clamping structure designs in high-power electrical machines by selecting materials and thicknesses that minimize losses while maintaining mechanical integrity.
16 November 2023 in IEEE Transactions on Magnetics
This paper deals with a combined experimental/numerical approach to identify the degradation profile of the magnetic properties at the cutting edge of mechanically cut electrical steels. Using a dedicated magnetic measurement device combined with a specific magnetic characterization protocol and mechanical hardness measurements, the impacted distance to the cutting-edge (I.C-E) of a non-oriented (NO) Si-Fe electrical steel has been experimentally delineated. Then, thanks to a magneto-plastic model together with a Finite Element (FE) method-based numerical model, the I.C-E distance and the associated degradation profile have been determined by an inverse optimization method. The obtained results show that the degradation profile, although it follows a classical rapid decrease from the cutting edge, is quite different from those usually considered in the literature.