Yunjun Rui

Prof. Yunjun Rui


Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 March 2018 in Nanomaterials
Verified
Journal Article
Open access
PDF file
YRYunjun Rui
Yunjun Rui
WZWeiliang Zhao
Weiliang Zhao
DZDewei Zhu
Dewei Zhu
HWHengyu Wang
Hengyu Wang
GSGuangliang Song
Guangliang Song
TZTianyou Zhang
Tianyou Zhang
In recent years, many research groups have synthesized ultra-thin silver nanowires (AgNWs) with diameters below 30 nm by employing Cl− and Br− simultaneously in the polyol process. However, the yield of AgNWs in this method was low, due to the production of Ag nanoparticles (AgNPs) as an unwanted byproduct, especially in the case of high Br− concentration. Here, we investigated the roles of Cl− and Br− in the preparation of AgNWs and then synthesized high aspect ratio (up to 2100) AgNWs in high yield (>85% AgNWs) using a Cl− and Br− co-mediated method. We found that multiply-twinned particles (MTPs) with different critical sizes were formed and grew into AgNWs, accompanied by a small and large amount of AgNPs for the NaCl and NaBr additives, respectively. For the first time, we propose that the growth of AgNWs of different diameters and yields can be understood based on the electron trap distribution (ETD) of the silver halide crystals. For the case of Cl− and Br− co-additives, a mixed silver halide crystal of AgBr1−xClx was formed, rather than the AgBr/AgCl mixture reported previously. In this type of crystal, the ETD is uniform, which is beneficial for the synthesis of AgNWs with small diameter (30~40 nm) and high aspect ratio. AgNW transparent electrodes were prepared in air by rod coating. A sheet resistance of 48 Ω/sq and transmittance of 95% at 550 nm were obtained without any post-treatment.

1 November 1994 in Solid State Communications
Verified
Journal Article
Closed access
HSH.M. Shao
H.M. Shao
KZK. Zhou
K. Zhou
YRYunjun Rui
Yunjun Rui
JSJ.C. Shen
J.C. Shen
XXX.N. Xu
X.N. Xu
ZZZ.X. Zhao
Z.X. Zhao

8 June 2021 in Journal of Materials Chemistry C
Verified
Journal Article
Closed access
PDF file
XCXinmiao Chen
Xinmiao Chen
LLLei Lu
Lei Lu
DGDawei Gu
Dawei Gu
XZXiaoyan Zhang
Xiaoyan Zhang
HYHe Yu
He Yu
YYYing Yang
Ying Yang
The printable HTM-free (HTM = hole transport materials) mesoporous carbon-based perovskite solar cells (C-PSCs) are one of the most promising technologies because of their simple production process, lost-cost and excellent stability. In this study, a novel and secure method is used to modify the original graphite, and the obtained chlorinated graphites (C–Clx, x = 0.2, 0.4, and 0.6) are applied to counter electrodes (CEs) in the printing of C-PSCs based on the TiO2/ZrO2/(5-AVA)x(MA)1−xPbI3/C–Clx structure. The experimental results show that C–Clx (x = 0.2, 0.4, and 0.6) can effectively improve the efficiency of C-PSCs. The mesoporous PSCs based on C–Cl0.4 CE have achieved an average efficiency of 11.81%, which is about 1.46-times of the pristine device with carbon CE, and the short-circuit current density (Jsc), fill factor (FF) and open-circuit voltage (Voc) increased by 15.8%, 11.7% and 11.2%, respectively. Simultaneously, a 30 day aging test showed that PSCs based on (5-AVA)x(MA)1−xPbI3 and C–Clx CEs showed excellent stability under ambient air conditions.

1 February 2019 in The Journal of Physical Chemistry C
Verified
Journal Article
Closed access
YRYunjun Rui
Yunjun Rui
TZTianmu Zhang
Tianmu Zhang
DZDewei Zhu
Dewei Zhu
YFYongji Feng
Yongji Feng
ACAlexander N. Cartwright
Alexander N. Cartwright
DGDawei Gu
Dawei Gu

12 November 2020 in European Journal of Physics
Verified
Journal Article
Closed access
HWHengyu Wang
Hengyu Wang
ZFZheng Fang
Zheng Fang
WZWeiliang Zhao
Weiliang Zhao
YRYunjun Rui
Yunjun Rui
In college physics experiments, a pendulum is often applied to measure the moment of inertia ( J ) of a rigid body. In this paper, we demonstrate a trifilar pendulum to determine not only J , but also the mass ( m ) of an irregular object. To this end, a standard weight is used to balance the pendulum, and a laser pointer is used to observe the amount of imbalance. According to the parallel axis theorem, a formula is deduced for the first time, which is related with m , J , oscillation period ( T ) of the pendulum, and the position ( d ) of the balancing standard. By the least squares fitting of a straight line to the experimental data of T 2 ∼ d 2 , m and J can be obtained from the slope and intercept, respectively. It is found that the relative differences (between the experimental and theoretical values) of m and J are both less than 5.0% when four irregular objects (a tuning fork, a stainless steel meter ruler, an apple, and a bunch of keys) are tested. The reason for the difference and the improvement of this measuring system are discussed.

7 January 2023 in Journal of Materials Science: Materials in Electronics
Verified
Journal Article
Closed access
PDF file
YJYu Jiang
Yu Jiang
RTRan Tao
Ran Tao
HZHaotian Zhang
Haotian Zhang
NWNeng Wan
Neng Wan
YYYing Yang
Ying Yang
JXJun Xu
Jun Xu