Marker-based motion capture (mocap) is a conventional method used in biomechanics research to precisely analyze human movement. However, the time-consuming marker placement process and extensive post-processing limit its wider adoption. Therefore, markerless mocap systems that use deep learning to estimate 2D keypoint from images have emerged as a promising alternative, but annotation errors in training datasets used by deep learning models can affect estimation accuracy. To improve the precision of 2D keypoint annotation, we present a method that uses anatomical landmarks based on marker-based mocap. Specifically, we use multiple RGB cameras synchronized and calibrated with a marker-based mocap system to create a high-quality dataset (RRIS40) of images annotated with surface anatomical landmarks. A deep neural network is then trained to estimate these 2D anatomical landmarks and a ray-distance-based triangulation is used to calculate the 3D marker positions. We conducted extensive evaluations on our RRIS40 test set, which consists of 10 subjects performing various movements. Compared against a marker-based system, our method achieves a mean Euclidean error of 13.23 mm in 3D marker position, which is comparable to the precision of marker placement itself. By learning directly to predict anatomical keypoints from images, our method outperforms OpenCap's augmentation of 3D anatomical landmarks from triangulated wild keypoints. This highlights the potential of facilitating wider integration of markerless mocap into biomechanics research. The RRIS40 test set is made publicly available for research purposes at koonyook.github.io/rris40 .
18 February 2025 in IEEE Journal of Biomedical and Health Informatics
Balance and gait impairments play a key role in falls among the elderly. Traditional clinical scales such as the Berg Balance Scale (BBS) to assess fall risk are often subjective, time consuming, and does not assess gait performance. Shorter assessments such as Timed Up and Go (TUG) are available, but most clinicians only look into the completion time. This study aimed to develop a fast, low-cost, and automated framework for balance function assessment and comprehensive gait analysis by enhancing the traditional TUG test with a markerless motion capture (MoCap) system and machine learning models. In total, we included TUG datasets of 70 participants with varying degrees of fall risk based on the BBS scores. We segmented TUG trials into five phases automatically using data from the MoCap system and extracted features from the phases. These features were then analyzed to identify those that significantly discriminate between high and low fall risk groups. Using the identified features, various machine learning models were tested to estimate the BBS scores. The markers obtained from the markerless MoCap system were used for detailed gait analysis, and lower limb kinematics were compared between the markerless and marker-based methods. Our findings indicate that individuals at high risk of falling had longer completion times, lower performance velocities, and smaller ranges of motion in lower-limb joints. Among the tested machine learning models, random forest demonstrated the best performance in predicting BBS scores (RMSE: 0.98, $R^{2}$: 0.94). Additionally, our markerless MoCap system showed comparable accuracy to state-of-the-art systems, eliminating the need to attach markers or sensors. The findings could help develop a quick and objective tool for balance and gait assessment in older adults, providing quantitative data to improve screening and intervention planning.
3 July 2022 in BMC Medical Informatics and Decision Making
Insightful feedback generation for daily home-based stroke rehabilitation is currently unavailable due to the inefficiency of exercise inspection done by therapists. We aim to produce a compact anomaly representation that allows a therapist to pay attention to only a few specific sections in a long exercise session record and boost their efficiency in feedback generation. This study proposes a data-driven technique to model a repetitive exercise using unsupervised phase learning on an artificial neural network and statistical learning on principal component analysis (PCA). After a model is built on a set of normal healthy movements, the model can be used to extract a sequence of anomaly scores from a movement of the same prescription. The method not only works on a standard marker-based motion capture system but also performs well on a more compact and affordable motion capture system based-on Kinect V2 and wrist-worn inertial measurement units that can be used at home. An evaluation of four different exercises shows its potential in separating anomalous movements from normal ones with an average area under the curve (AUC) of 0.9872 even on the compact motion capture system. The proposed processing technique has the potential to help clinicians in providing high-quality feedback for telerehabilitation in a more scalable way.
This paper presents a calibration approach for multiple synchronized global-shutter RGB cameras surrounding a large capture volume for 3D application. The calibration approach uses an active wand with two LED-embedded markers waved manually within the target capture volume. Data from the waving wand are combined with chessboard images taken at close range during each camera’s intrinsic calibration, optimizing camera parameters via our proposed bundle adjustment method. These additional constraints from the chessboard are developed to overcome an overfitting issue of wand-based calibration discovered by benchmarking its 3D triangulation accuracy in an independent record against a ground-truth trajectory and not on the record used for calibration itself. Addressing this overfitting issue in bundle adjustment leads to significant improvements in both 3D accuracy and result consistency. As a by-product of this development, a new benchmarking workflow and our calibration dataset that reflects realistic 3D accuracy are proposed and made publicly available to allow for fair comparisons of various calibration methods in the future. Additionally, our experiment highlights a significant benefit of a ray distance-based (RDB) triangulation formula over the popular direct linear transformation (DLT) method.