Wee Sen Lim

Wee Sen Lim

Auto-generated profile, based on publicly available information

Wee Sen Lim

Rehabilitation Research Institute of Singapore, Nanyang Technological University, Singapore

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 July 2024 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
PJPrayook Jatesiktat
Prayook Jatesiktat
GLGuan Ming Lim
Guan Ming Lim
WLWee Sen Lim
Wee Sen Lim
WAWei Tech Ang
Wei Tech Ang
Marker-based motion capture (mocap) is a conventional method used in biomechanics research to precisely analyze human movement. However, the time-consuming marker placement process and extensive post-processing limit its wider adoption. Therefore, markerless mocap systems that use deep learning to estimate 2D keypoint from images have emerged as a promising alternative, but annotation errors in training datasets used by deep learning models can affect estimation accuracy. To improve the precision of 2D keypoint annotation, we present a method that uses anatomical landmarks based on marker-based mocap. Specifically, we use multiple RGB cameras synchronized and calibrated with a marker-based mocap system to create a high-quality dataset (RRIS40) of images annotated with surface anatomical landmarks. A deep neural network is then trained to estimate these 2D anatomical landmarks and a ray-distance-based triangulation is used to calculate the 3D marker positions. We conducted extensive evaluations on our RRIS40 test set, which consists of 10 subjects performing various movements. Compared against a marker-based system, our method achieves a mean Euclidean error of 13.23 mm in 3D marker position, which is comparable to the precision of marker placement itself. By learning directly to predict anatomical keypoints from images, our method outperforms OpenCap's augmentation of 3D anatomical landmarks from triangulated wild keypoints. This highlights the potential of facilitating wider integration of markerless mocap into biomechanics research. The RRIS40 test set is made publicly available for research purposes at koonyook.github.io/rris40 .

8 August 2023
Verified
Conference Paper
Open access
PJPrayook Jatesiktat
Prayook Jatesiktat
WLWee Sen Lim
Wee Sen Lim
JLJun Liang Lau
Jun Liang Lau
SCSIAW MENG CHOU
SIAW MENG CHOU
DLDenny Tjiauw Tjoen Lie
Denny Tjiauw Tjoen Lie
WAWei Tech Ang
Wei Tech Ang
This paper presents a pilot study that uses a markerless motion capture system to measure active shoulder joint range of motion in a clinic room. The measurements from this automated method are compared with manual measurements done by a clinician using a goniometer. All the parameters from both methods are positively correlated. The root-mean-square differences from the comparisons are in the range of 7.21° – 15.87° depending on the type of angles. With a careful protocol design and execution, the markerless motion capture system can potentially be used as an objective shoulder range of motion assessment tool in clinical practice.