Bénédicte Delattre

Dr. Bénédicte Delattre

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2010 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
BDBénédicte Delattre
Bénédicte Delattre
RHRobin M. Heidemann
Robin M. Heidemann
LCLindsey A. Crowe
Lindsey A. Crowe
JVJean-Paul Vallée
Jean-Paul Vallée
JHJean-Noël Hyacinthe
Jean-Noël Hyacinthe

1 July 2019 in European Radiology
Verified
Journal Article
Closed access
PDF file
BDBénédicte Delattre
Bénédicte Delattre
SBSana Boudabbous
Sana Boudabbous
CHCatrina Hansen
Catrina Hansen
ANAngeliki Neroladaki
Angeliki Neroladaki
AHAnne-Lise Hachulla
Anne-Lise Hachulla
MVMaria Isabel Vargas
Maria Isabel Vargas

1 March 2018 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
MDM. Drake-Pérez
M. Drake-Pérez
BDBénédicte Delattre
Bénédicte Delattre
JBJ. Boto
J. Boto
AFAikaterini Fitsiori
Aikaterini Fitsiori
Karl Olof LovbladKarl Olof Lovblad
Karl Olof Lovblad
MVM.I. Vargas
M.I. Vargas
BACKGROUND AND PURPOSE: SyMRI is a technique developed to perform quantitative MR imaging. Our aim was to analyze its potential use for measuring relaxation times of normal components of the spine and to compare them with values found in the literature using relaxometry and other techniques. MATERIALS AND METHODS: Thirty-two spine MR imaging studies (10 cervical, 5 dorsal, 17 lumbosacral) were included. A modified multiple-dynamic multiple-echo sequence was added and processed to obtain quantitative T1 (millisecond), T2 (millisecond), and proton density (percentage units [pu]) maps for each patient. An ROI was placed on representative areas for CSF, spinal cord, intervertebral discs, and vertebral bodies, to measure their relaxation. RESULTS: Relaxation time means are reported for CSF (T1 = 4273.4 ms; T2 = 1577.6 ms; proton density = 107.5 pu), spinal cord (T1 = 780.2 ms; T2 = 101.6 ms; proton density = 58.7 pu), normal disc (T1 = 1164.9 ms; T2 = 101.9 ms; proton density = 78.9 pu), intermediately hydrated disc (T1 = 723 ms; T2 = 66.8 ms; proton density = 60.8 pu), desiccated disc (T1 = 554.4 ms; T2 = 55.6 ms; proton density = 47.6 ms), and vertebral body (T1 = 515.3 ms; T2 = 100.8 ms; proton density = 91.1 pu). Comparisons among the mean T1, T2, and proton density values showed significant differences between different spinal levels (cervical, dorsal, lumbar, and sacral) for CSF (proton density), spinal cord (T2 and proton density), normal disc (T1, T2, and proton density), and vertebral bodies (T1 and proton density). Significant differences were found among mean T1, T2, and proton density values of normal, intermediately hydrated, and desiccated discs. CONCLUSIONS: Measurements can be easily obtained on SyMRI and correlated with previously published values obtained using conventional relaxometry techniques.

2 August 2018 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
MVM.I. Vargas
M.I. Vargas
MDM. Drake-Pérez
M. Drake-Pérez
BDBénédicte Delattre
Bénédicte Delattre
JBJ. Boto
J. Boto
Karl Olof LovbladKarl Olof Lovblad
Karl Olof Lovblad
SBS. Boudabous
S. Boudabous
BACKGROUND AND PURPOSE: Synthetic MR imaging is a method that can produce multiple contrasts from a single sequence, as well as quantitative maps. Our aim was to determine the feasibility of a synthetic MR image for spine imaging. MATERIALS AND METHODS: Thirty-eight patients with clinical indications of infectious, degenerative, and neoplastic disease underwent an MR imaging of the spine (11 cervical, 8 dorsal, and 19 lumbosacral MR imaging studies). The SyntAc sequence, with an acquisition time of 5 minutes 40 seconds, was added to the usual imaging protocol consisting of conventional sagittal T1 TSE, T2 TSE, and STIR TSE. RESULTS: Synthetic T1-weighted, T2-weighted, and STIR images were of adequate quality, and the acquisition time was 53% less than with conventional MR imaging. The image quality was rated as “good” for both synthetic and conventional images. Interreader agreement concerning lesion conspicuity was good with a Cohen κ of 0.737. Artifacts consisting of white pixels/spike noise across contrast views, as well as flow artifacts, were more common in the synthetic sequences, particularly in synthetic STIR. There were no statistically significant differences between readers concerning the scores assigned for image quality or lesion conspicuity. CONCLUSIONS: Our study shows that synthetic MR imaging is feasible in spine imaging and produces, in general, good image quality and diagnostic confidence. Furthermore, the non-negligible time savings and the ability to obtain quantitative measurements as well as to generate several contrasts with a single acquisition should promise a bright future for synthetic MR imaging in clinical routine.

11 June 2010 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
BDBénédicte Delattre
Bénédicte Delattre
VBVincent Braunersreuther
Vincent Braunersreuther
JHJean‐Noël Hyacinthe
Jean‐Noël Hyacinthe
LCLindsey A. Crowe
Lindsey A. Crowe
FMFrançois Mach
François Mach
JVJean‐Paul Vallée
Jean‐Paul Vallée

13 February 2020 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
TST. Su
T. Su
PRP. Reymond
P. Reymond
OBO. Brina
O. Brina
PBP. Bouillot
P. Bouillot
PMP. Machi
P. Machi
MVM.I. Vargas
M.I. Vargas
BACKGROUND AND PURPOSE: Flow diverter–induced hemodynamic change plays an important role in the mechanism of intracranial aneurysm occlusion. Our aim was to explore the relationship between aneurysm features and flow-diverter treatment of unruptured sidewall intracranial aneurysms. MATERIALS AND METHODS: MR imaging, 4D phase-contrast, was prospectively performed before flow diverter implantation in each patient with unruptured intracranial aneurysm. Two postprocedure follow-ups were scheduled at 6 and 12 months. Responses were grouped according to whether the aneurysms were occluded or remnant. Preprocedural aneurysm geometries and ostium hemodynamics in 38 patients were compared between the 2 groups at 6 and 12 months. Receiver operating characteristic curve analyses were performed for significant geometric and hemodynamic continuous parameters. RESULTS: After the 6-month assessment, 21 of 41 intracranial aneurysms were occluded, and 9 additional aneurysms were occluded at 12 months. Geometrically, the ostium maximum diameter was significantly larger in the remnant group at 6 and 12 months (both P < .001). Hemodynamically, the proximal inflow zone was more frequently observed in the remnant group at 6 months. Several preprocedural ostium hemodynamic parameters were significantly higher in the remnant group. As a prediction for occlusion, the areas under the curve of the ostium maximum diameter (for 6 and 12 months), systolic inflow rate ratio (for 6 months), and systolic inflow area (for 12 months) reached 0.843, 0.883, 0.855, and 0.860, respectively. CONCLUSIONS: Intracranial aneurysms with a large ostium and strong ostium inflow may need a longer time for occlusion. Preprocedural 4D flow MR imaging can well illustrate ostium hemodynamics and characterize aneurysm treatment responses.