Hyperpolarized substrates prepared via dissolution dynamic nuclear polarization have been proposed as magnetic resonance imaging (MRI) agents for cancer or cardiac failure diagnosis and therapy monitoring through the detection of metabolic impairments in vivo. The use of potentially toxic persistent radicals to hyperpolarize substrates was hitherto required. We demonstrate that by shining UV light for an hour on a frozen pure endogenous substance, namely the glucose metabolic product pyruvic acid, it is possible to generate a concentration of photo-induced radicals that is large enough to highly enhance the 13C polarization of the substance via dynamic nuclear polarization. These radicals recombine upon dissolution and a solution composed of purely endogenous products is obtained for performing in vivo metabolic hyperpolarized 13C MRI with high spatial resolution. Our method opens the way to safe and straightforward preclinical and clinical applications of hyperpolarized MRI because the filtering procedure mandatory for clinical applications and the associated pharmacological tests necessary to prevent contamination are eliminated, concurrently allowing a decrease in the delay between preparation and injection of the imaging agents for improved in vivo sensitivity.
MR acoustic radiation force imaging (ARFI) is an elegant adjunct to MR‐guided high intensity focused ultrasound for treatment planning and optimization, permitting in situ assessment of the focusing and targeting quality. The thermal effect of high intensity focused ultrasound pulses associated with ARFI measurements is recommended to be monitored on line, in particular when the beam crosses highly absorbent structures or interfaces (e.g., bones or air‐filled cavities). A dedicated MR sequence is proposed here, derived from a segmented gradient echo‐echo planar imaging kernel by adding a bipolar motion encoding gradient with interleaved alternating polarities. Temporal resolution was reduced to 2.1 s, with in‐plane spatial resolution of 1 mm. MR‐ARFI measurements were executed during controlled animal breathing, with trans‐costal successively steered foci, to investigate the spatial modulation of the focus intensity and the targeting offset. ARFI‐induced tissue displacement measurements enabled the accurate localization, in vivo, of the high intensity focused ultrasound focal point in sheep liver, with simultaneous monitoring of the temperature elevation. ARFI‐based precalibration of the focal point position was immediately followed by trans‐costal MR‐guided high intensity focused ultrasound ablation, monitored with a conventional proton resonance frequency shift MR thermometry sequence. The latter MR thermometry sequence had spatial resolution and geometrical distortion identical with the ARFI maps, hence no coregistration was required. Magn Reson Med, 2012.
The purposes of this study were to assess the extent of the inflow effect on signal intensity (SI) for fast gradient‐recalled‐echo (GRE) sequences used to observe first‐pass perfusion, and to develop and validate a correction method for this effect. A phantom experiment with a flow apparatus was performed to determine SI as a function of Gd‐DTPA concentration for various velocities. Subsequently a flow‐sensitive calibration method was developed, and validated on bolus injections into an open‐circuit flow apparatus and in vivo. It is shown that calibration methods based on static phantoms are not appropriate for accurate signal‐to‐concentration conversion in images affected by high flow. The flow‐corrected calibration method presented here can be used to improve the accuracy and robustness of the arterial input function (AIF) determination for tissue perfusion quantification using MRI and contrast media. Magn Reson Med 50:885–891, 2003.
17 September 2015 in The Journal of Physical Chemistry C
A high throughput method was designed to produce hyperpolarized gases by combining low-temperature dynamic nuclear polarization with a sublimation procedure. It is illustrated by applications to nuclear magnetic resonance in xenon gas, leading to a signal enhancement of 3 to 4 orders of magnitude compared to the room-temperature thermal equilibrium signal at 7.05 T.