Yu Wang

Dr. Yu Wang

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2025 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
WWWeice Wang
Weice Wang
YGYitong Guo
Yitong Guo
MZMingxu Zhu
Mingxu Zhu
WLWeichen Li
Weichen Li
YWYu Wang
Yu Wang
XSXuetao Shi
Xuetao Shi
Blood is a vital component of the human body, and alterations in its dielectric properties can result in changes to the dielectric properties of vital organs and even the entire body. This, in turn, affects the accuracy of bioelectromagnetic techniques such as thoracic electrical bioimpedance, electrical impedance tomography (EIT) and the body composition analysis and body fluid management based on biological impedance measurement. To detect brain damage signals by EIT during cardiopulmonary bypass, where significant alterations in blood composition are observed, it is first necessary to investigate the change of blood dielectric parameters. Accordingly, the purpose of this study is to elucidate the blood dielectric parameters of patients through blood gas indicators and frequency. A correlation analysis was used to ascertain the blood gas indicators that exert a significant influence on the blood dielectric parameters within 10 Hz–100 MHz. Based on these findings, a series of regression models were constructed to determine the dielectric parameters. This study is the first to demonstrate that pH, partial pressure of oxygen (PO2), partial pressure of carbon dioxide (PCO2), K+, and Ca2+ concentrations significantly influence blood dielectric properties. The results of the cross-validation and statistical analysis demonstrated that the Gaussian process regression is an effective method for accurately determining the blood dielectric parameters based on blood gas indicators and frequency, with good generalization performance. This finding has the potential to facilitate the effective extraction of brain damage signals by EIT, while also advancing the field of biophysics, biosensors, bioelectromagnetic technology, and electromagnetic modeling of the human body.

31 October 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
WWWeice Wang
Weice Wang
LHLihua Hou
Lihua Hou
CXCanhua Xu
Canhua Xu
MZMingxu Zhu
Mingxu Zhu
YGYitong Guo
Yitong Guo
XSXuetao Shi
Xuetao Shi
Mannitol dehydration is routinely used to prevent and treat cerebral damage after total aortic arch replacement (TAAR), but existing neuroimaging technologies cannot achieve bedside real-time quantitative assessment of its impact on cerebral perfusion in different patients. This study applied dynamic cerebral perfusion electrical impedance tomography (DCP-EIT), a non-invasive neuroimaging technique, for bedside cerebral perfusion monitoring in TAAR patients during dehydration. Seventeen patients with normal neurological function and nineteen with neurological dysfunction (ND) were enrolled. The variation patterns and differences in perfusion impedance, images, and the relative ratios (RY) of mean perfusion velocity (MV), height of systolic wave (Hs), inflow volume velocity (IV), and angle between the ascending branch and baseline (Aab) were analyzed. Results showed DCP-EIT could visualize cerebral perfusion changes, with detected poorly perfused regions showing good consistency with ischemic areas identified by computed tomography (CT). RY of normal patients fluctuated around 0.97–1.04, with no significant difference from baseline. RY of ND patients peaked at 14–20 min after dehydration and remained higher than baseline even at 100 min (p < 0.001). DCP-EIT holds potential to optimize individualized cerebral protection strategies for other cerebral damage scenarios and neurocritical care.

11 December 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YGYitong Guo
Yitong Guo
SPShujia Peng
Shujia Peng
JLJunyao Li
Junyao Li
RSRuteng Song
Ruteng Song
MZMingxu Zhu
Mingxu Zhu
XSXuetao Shi
Xuetao Shi
Accurate non-invasive temperature monitoring during liver tumor hyperthermia remains a significant clinical challenge. This study evaluates the use of electrical impedance tomography (EIT) for quantitative temperature mapping in hepatic thermal therapy by incorporating tissue-specific electrophysiological properties. Based on prior characterization of temperature-dependent electrical conductivity (30–90°C, 1 Hz–1 MHz) in murine hepatocellular carcinoma (HCC) models, computational simulations were developed to demonstrate EIT reconstructed value-temperature correlations. In vivo validation was conducted using orthotopic HCC mice subjected to infrared laser heating (n=6) and radiofrequency ablation (RFA) (n=4), with thermal changes monitored via a custom 16-electrode EIT system operating at 10 kHz. A novel 3D-printed scaffold ensured stable electrode placement on the abdominal surface. Region-of-interest analysis defined tumor, heat affected liver, and distal liver zones. Results revealed strong linear correlations (R²=0.88– 0.93, p<0.0001) between EIT-reconstructed values and thermocouple measured temperatures through tissue-specific temperature-dependent impedance functions. EIT accurately localized thermal lesions and visualized the spatiotemporal evolution of temperature during ablation, with quantification errors of ≤2.8°C (tumor tissue), ≤3.6°C (heated liver tissue), and ≤4.5°C (distal liver tissue), as histologically confirmed. We believe that the technology holds significant potential for improving treatment efficacy in HCC hyperthermia protocols through non-invasive temperature quantification.

20 November 2024 in Sensors
Verified
Journal Article
Open access
PDF file
WWWeice Wang
Weice Wang
MZMingxu Zhu
Mingxu Zhu
BLBenyuan Liu
Benyuan Liu
WLWeichen Li
Weichen Li
YWYu Wang
Yu Wang
XSXuetao Shi
Xuetao Shi
Accurate human cerebrospinal fluid (CSF) dielectric parameters are critical for biological electromagnetic applications such as the electromagnetic field modelling of the human brain, the localization and intensity assessment of electrical generators in the brain, and electromagnetic protection. To detect brain damage signals during temperature changes by electrical impedance tomography (EIT), the change in CSF dielectric parameters with frequency (10 Hz–100 MHz) and temperature (17–39 °C) was investigated. A Debye model was first established to capture the complex impedance frequency and temperature characteristics. Furthermore, the receiver operating characteristic (ROC) analysis based on the dielectric parameters of normal and diseased CSF was carried out to identify lesions. The Debye model’s characteristic fc parameters linearly increased with increasing temperature (R2 = 0.989), and R0 and R1 linearly decreased (R2 = 0.990). The final established formula can calculate the complex impedivity of CSF with a maximum fitting error of 3.79%. Furthermore, the ROC based on the real part of impedivity at 10 Hz and 17 °C yielded an area under the curve (AUC) of 0.898 with a specificity of 0.889 and a sensitivity of 0.944. These findings are expected to facilitate the application of electromagnetic technology, such as disease diagnosis, specific absorption rate calculation, and biosensor design.