Mingxu Zhu

Dr. Mingxu Zhu


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
WWWeice Wang
Weice Wang
LHLihua Hou
Lihua Hou
CXCanhua Xu
Canhua Xu
MZMingxu Zhu
Mingxu Zhu
YGYitong Guo
Yitong Guo
XSXuetao Shi
Xuetao Shi
Mannitol dehydration is routinely used to prevent and treat cerebral damage after total aortic arch replacement (TAAR), but existing neuroimaging technologies cannot achieve bedside real-time quantitative assessment of its impact on cerebral perfusion in different patients. This study applied dynamic cerebral perfusion electrical impedance tomography (DCP-EIT), a non-invasive neuroimaging technique, for bedside cerebral perfusion monitoring in TAAR patients during dehydration. Seventeen patients with normal neurological function and nineteen with neurological dysfunction (ND) were enrolled. The variation patterns and differences in perfusion impedance, images, and the relative ratios (RY) of mean perfusion velocity (MV), height of systolic wave (Hs), inflow volume velocity (IV), and angle between the ascending branch and baseline (Aab) were analyzed. Results showed DCP-EIT could visualize cerebral perfusion changes, with detected poorly perfused regions showing good consistency with ischemic areas identified by computed tomography (CT). RY of normal patients fluctuated around 0.97–1.04, with no significant difference from baseline. RY of ND patients peaked at 14–20 min after dehydration and remained higher than baseline even at 100 min (p < 0.001). DCP-EIT holds potential to optimize individualized cerebral protection strategies for other cerebral damage scenarios and neurocritical care.

1 September 2024 in International Journal of Hyperthermia
Verified
Journal Article
Open access
YGYitong Guo
Yitong Guo
WWWeice Wang
Weice Wang
WLWeichen Li
Weichen Li
JLJunyao Li
Junyao Li
MZMingxu Zhu
Mingxu Zhu
XSXuetao Shi
Xuetao Shi
Objective: Understansding the changing patterns of in vivo electrical properties for the target tissue is crucial for the accurate temperature monitoring and the treatment efficacy in thermal therapy. Our research aims to investigate the changing patterns and the reversibility of in vivo electrical properties for both healthy livers and liver tumors in a mouse model over a frequency range of 1 Hz to 1 MHz at temperatures between 30 °C to 90 °C. Methods and materials: The mice were anesthetized and the target organ was exposed. An 808-nm near-infrared laser was employed as the heating source to heat the organ in vivo. The four-needle electrode, connected to an impedance analyzer, was utilized to obtain the impedance at varying temperatures, which were monitored by a thermocouple. Results: The findings indicated a gradual decline in impedance with an increase in temperature. Furthermore, the impedance was normalized to that at 30 °C, and the real part of the normalized impedance was defined as the k-values, which range from 0 to 1. The results demonstrated a linear correlation between k-values and temperatures (R2 > 0.9 for livers and R2 > 0.8 for tumors). Significant differences were observed between livers and tumors at 1, 10 and 50 kHz (p < 0.05). Additionally, it was demonstrated that the electrical properties could be reversed when the temperature was below or equal to 45 °C. Conclusion: We believe that these results will contribute to the advancement of radiofrequency ablation systems and the development of techniques for temperature monitoring during liver thermal treatment.

11 December 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YGYitong Guo
Yitong Guo
SPShujia Peng
Shujia Peng
JLJunyao Li
Junyao Li
RSRuteng Song
Ruteng Song
MZMingxu Zhu
Mingxu Zhu
XSXuetao Shi
Xuetao Shi
Accurate non-invasive temperature monitoring during liver tumor hyperthermia remains a significant clinical challenge. This study evaluates the use of electrical impedance tomography (EIT) for quantitative temperature mapping in hepatic thermal therapy by incorporating tissue-specific electrophysiological properties. Based on prior characterization of temperature-dependent electrical conductivity (30–90°C, 1 Hz–1 MHz) in murine hepatocellular carcinoma (HCC) models, computational simulations were developed to demonstrate EIT reconstructed value-temperature correlations. In vivo validation was conducted using orthotopic HCC mice subjected to infrared laser heating (n=6) and radiofrequency ablation (RFA) (n=4), with thermal changes monitored via a custom 16-electrode EIT system operating at 10 kHz. A novel 3D-printed scaffold ensured stable electrode placement on the abdominal surface. Region-of-interest analysis defined tumor, heat affected liver, and distal liver zones. Results revealed strong linear correlations (R²=0.88– 0.93, p<0.0001) between EIT-reconstructed values and thermocouple measured temperatures through tissue-specific temperature-dependent impedance functions. EIT accurately localized thermal lesions and visualized the spatiotemporal evolution of temperature during ablation, with quantification errors of ≤2.8°C (tumor tissue), ≤3.6°C (heated liver tissue), and ≤4.5°C (distal liver tissue), as histologically confirmed. We believe that the technology holds significant potential for improving treatment efficacy in HCC hyperthermia protocols through non-invasive temperature quantification.

20 November 2024 in Sensors
Verified
Journal Article
Open access
PDF file
WWWeice Wang
Weice Wang
MZMingxu Zhu
Mingxu Zhu
BLBenyuan Liu
Benyuan Liu
WLWeichen Li
Weichen Li
YWYu Wang
Yu Wang
XSXuetao Shi
Xuetao Shi
Accurate human cerebrospinal fluid (CSF) dielectric parameters are critical for biological electromagnetic applications such as the electromagnetic field modelling of the human brain, the localization and intensity assessment of electrical generators in the brain, and electromagnetic protection. To detect brain damage signals during temperature changes by electrical impedance tomography (EIT), the change in CSF dielectric parameters with frequency (10 Hz–100 MHz) and temperature (17–39 °C) was investigated. A Debye model was first established to capture the complex impedance frequency and temperature characteristics. Furthermore, the receiver operating characteristic (ROC) analysis based on the dielectric parameters of normal and diseased CSF was carried out to identify lesions. The Debye model’s characteristic fc parameters linearly increased with increasing temperature (R2 = 0.989), and R0 and R1 linearly decreased (R2 = 0.990). The final established formula can calculate the complex impedivity of CSF with a maximum fitting error of 3.79%. Furthermore, the ROC based on the real part of impedivity at 10 Hz and 17 °C yielded an area under the curve (AUC) of 0.898 with a specificity of 0.889 and a sensitivity of 0.944. These findings are expected to facilitate the application of electromagnetic technology, such as disease diagnosis, specific absorption rate calculation, and biosensor design.