Objective: Understansding the changing patterns of in vivo electrical properties for the target tissue is crucial for the accurate temperature monitoring and the treatment efficacy in thermal therapy. Our research aims to investigate the changing patterns and the reversibility of in vivo electrical properties for both healthy livers and liver tumors in a mouse model over a frequency range of 1 Hz to 1 MHz at temperatures between 30 °C to 90 °C. Methods and materials: The mice were anesthetized and the target organ was exposed. An 808-nm near-infrared laser was employed as the heating source to heat the organ in vivo. The four-needle electrode, connected to an impedance analyzer, was utilized to obtain the impedance at varying temperatures, which were monitored by a thermocouple. Results: The findings indicated a gradual decline in impedance with an increase in temperature. Furthermore, the impedance was normalized to that at 30 °C, and the real part of the normalized impedance was defined as the k-values, which range from 0 to 1. The results demonstrated a linear correlation between k-values and temperatures (R2 > 0.9 for livers and R2 > 0.8 for tumors). Significant differences were observed between livers and tumors at 1, 10 and 50 kHz (p < 0.05). Additionally, it was demonstrated that the electrical properties could be reversed when the temperature was below or equal to 45 °C. Conclusion: We believe that these results will contribute to the advancement of radiofrequency ablation systems and the development of techniques for temperature monitoring during liver thermal treatment.
12 May 2025 in Journal of Physics D: Applied Physics
Blood is a vital component of the human body, and alterations in its dielectric properties can result in changes to the dielectric properties of vital organs and even the entire body. This, in turn, affects the accuracy of bioelectromagnetic techniques such as thoracic electrical bioimpedance, electrical impedance tomography (EIT) and the body composition analysis and body fluid management based on biological impedance measurement. To detect brain damage signals by EIT during cardiopulmonary bypass, where significant alterations in blood composition are observed, it is first necessary to investigate the change of blood dielectric parameters. Accordingly, the purpose of this study is to elucidate the blood dielectric parameters of patients through blood gas indicators and frequency. A correlation analysis was used to ascertain the blood gas indicators that exert a significant influence on the blood dielectric parameters within 10 Hz–100 MHz. Based on these findings, a series of regression models were constructed to determine the dielectric parameters. This study is the first to demonstrate that pH, partial pressure of oxygen (PO2), partial pressure of carbon dioxide (PCO2), K+, and Ca2+ concentrations significantly influence blood dielectric properties. The results of the cross-validation and statistical analysis demonstrated that the Gaussian process regression is an effective method for accurately determining the blood dielectric parameters based on blood gas indicators and frequency, with good generalization performance. This finding has the potential to facilitate the effective extraction of brain damage signals by EIT, while also advancing the field of biophysics, biosensors, bioelectromagnetic technology, and electromagnetic modeling of the human body.
Mannitol dehydration is routinely used to prevent and treat cerebral damage after total aortic arch replacement (TAAR), but existing neuroimaging technologies cannot achieve bedside real-time quantitative assessment of its impact on cerebral perfusion in different patients. This study applied dynamic cerebral perfusion electrical impedance tomography (DCP-EIT), a non-invasive neuroimaging technique, for bedside cerebral perfusion monitoring in TAAR patients during dehydration. Seventeen patients with normal neurological function and nineteen with neurological dysfunction (ND) were enrolled. The variation patterns and differences in perfusion impedance, images, and the relative ratios (RY) of mean perfusion velocity (MV), height of systolic wave (Hs), inflow volume velocity (IV), and angle between the ascending branch and baseline (Aab) were analyzed. Results showed DCP-EIT could visualize cerebral perfusion changes, with detected poorly perfused regions showing good consistency with ischemic areas identified by computed tomography (CT). RY of normal patients fluctuated around 0.97–1.04, with no significant difference from baseline. RY of ND patients peaked at 14–20 min after dehydration and remained higher than baseline even at 100 min (p < 0.001). DCP-EIT holds potential to optimize individualized cerebral protection strategies for other cerebral damage scenarios and neurocritical care.
Accurate human cerebrospinal fluid (CSF) dielectric parameters are critical for biological electromagnetic applications such as the electromagnetic field modelling of the human brain, the localization and intensity assessment of electrical generators in the brain, and electromagnetic protection. To detect brain damage signals during temperature changes by electrical impedance tomography (EIT), the change in CSF dielectric parameters with frequency (10 Hz–100 MHz) and temperature (17–39 °C) was investigated. A Debye model was first established to capture the complex impedance frequency and temperature characteristics. Furthermore, the receiver operating characteristic (ROC) analysis based on the dielectric parameters of normal and diseased CSF was carried out to identify lesions. The Debye model’s characteristic fc parameters linearly increased with increasing temperature (R2 = 0.989), and R0 and R1 linearly decreased (R2 = 0.990). The final established formula can calculate the complex impedivity of CSF with a maximum fitting error of 3.79%. Furthermore, the ROC based on the real part of impedivity at 10 Hz and 17 °C yielded an area under the curve (AUC) of 0.898 with a specificity of 0.889 and a sensitivity of 0.944. These findings are expected to facilitate the application of electromagnetic technology, such as disease diagnosis, specific absorption rate calculation, and biosensor design.