Geng Li

Dr. Geng Li


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
CHClaire V. Hammond
Claire V. Hammond
SWSpencer T. Williams
Spencer T. Williams
MVMarleny M. Vega
Marleny M. Vega
DAD. Ao
D. Ao
GLGeng Li
Geng Li
Benjamin FreglyBenjamin Fregly
Benjamin Fregly
Neuromusculoskeletal injuries including osteoarthritis, stroke, spinal cord injury, and traumatic brain injury affect roughly 19% of the U.S. adult population. Standardized interventions have produced suboptimal functional outcomes due to the unique treatment needs of each patient. Strides have been made to utilize computational models to develop personalized treatments, but researchers and clinicians have yet to cross the “valley of death” between fundamental research and clinical usefulness. This article introduces the Neuromusculoskeletal Modeling (NMSM) Pipeline, two MATLAB-based toolsets that add Model Personalization and Treatment Optimization functionality to OpenSim. The two toolsets facilitate computational design of individualized treatments for neuromusculoskeletal impairments through the use of personalized neuromusculoskeletal models and predictive simulation. The Model Personalization toolset contains four tools for personalizing 1) joint structure models, 2) muscle-tendon models, 3) neural control models, and 4) foot-ground contact models. The Treatment Optimization toolset contains three tools for predicting and optimizing a patient’s functional outcome for different treatment options using a patient’s personalized neuromusculoskeletal model with direct collocation optimal control methods. Support for user-defined cost functions and model modification functions facilitate simulation of a vast number of possible treatments. An NMSM Pipeline use case is presented for an individual post-stroke with impaired walking function, where the goal was to predict how the subject’s neural control could be changed to improve walking speed without increasing metabolic cost. First the Model Personalization toolset was used to develop a personalized neuromusculoskeletal model of the subject starting from a generic OpenSim full- body model and experimental walking data (video motion capture, ground reaction, and electromyography) collected from the subject at his self-selected speed. Next the Treatment Optimization toolset was used with the personalized model to predict how the subject could recruit existing muscle synergies more effectively to reduce muscle activation disparities between the paretic and non-paretic legs. The software predicted that the subject could increase his walking speed by 60% without increasing his metabolic cost per unit time by modifying existing muscle synergy recruitment. This hypothetical treatment demonstrates how NMSM Pipeline tools could allow researchers working collaboratively with clinicians to develop personalized neuromusculoskeletal models of individual patients and to perform predictive simulations for the purpose of designing personalized treatments that maximize a patient’s post-treatment functional outcome.

6 August 2020 in bioRxiv
Verified
Preprint
Open access
PDF file
GLGeng Li
Geng Li
MSMohammad S. Shourijeh
Mohammad S. Shourijeh
DADi Ao
Di Ao
CPCarolynn Patten
Carolynn Patten
Benjamin FreglyBenjamin Fregly
Benjamin Fregly
Muscle co-contraction generates joint stiffness to improve stability and accuracy during limb movement but at the expense of higher energetic cost. The quantification of joint stiffness generated from muscle co-contraction is difficult through both experimental and computational means for its benefit and cost to be assessed. Quantification of muscle co-contraction may offer an alternative path for estimating joint stiffness. By choosing the commonly used Co-Contraction Indices (CCIs) to represent muscle co-contraction, this study investigated the feasibility of using CCI to approximate lower limb joint stiffness trends during gait. A calibrated EMG-driven musculoskeletal model of a hemiparetic individual post-stroke from a previous study was used to generate the quantities required for CCI calculation and model-based estimation of joint stiffness. A total of 14 classes of CCIs for various combinations of antagonistic muscle pairs were calculated based on two common CCI formulations, each with 7 types of quantities that included variations of electromyography (EMG) signals and joint moments from the muscles. Correlations between CCIs and model-based estimates of sagittal plane stiffness of the lower extremity joints (hip, knee, ankle) were computed. Although moderate to strong correlation was observed between some CCI formulations and the corresponding joint stiffness, these associations were highly dependent on the methodological choices made for CCI computation. The overall findings of this study were the following: (1) the formulation proposed by Rudolph et al. (2000), CCI 1 , was more correlated with joint stiffness than that of Falconer and Winter (1985); (2) Moment-based CCI 1 from individual antagonistic muscle pairs was more correlated than EMG-based CCI 1 ; (3) EMG signals with calibrated electromechanical delay and joint moment generated by individual muscle without normalization to a reference value were the most correlated for EMG-based CCI 1 and moment-based CCI 1 , respectively. The combination of antagonistic muscle pairs for most correlated within each CCI class was also identified. By using CCI to approximate joint stiffness trends, this study may open an alternative path to studying joint stiffness.

12 November 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YZYuhui Zhu
Yuhui Zhu
ANAta Babazadeh Naseri
Ata Babazadeh Naseri
MBMatthew RW Brake
Matthew RW Brake
JAJohn Edward Akin
John Edward Akin
GLGeng Li
Geng Li
Benjamin FreglyBenjamin Fregly
Benjamin Fregly
Custom implants used for pelvic reconstruction in pelvic sarcoma surgery face a high complication rate due to mechanical failures of fixation screws. Consequently, patient-specific finite element (FE) models have been employed to analyze custom pelvic implant durability. However, muscle forces have often been omitted from FE studies of the post-operative pelvis with a custom implant, despite the lack of evidence that this omission has minimal impact on predicted bone, implant, and fixation screw stress distributions. This study investigated the influence of muscle forces on FE predictions of fixation screw pullout and fatigue failure in a custom pelvic implant. Specifically, FE analyses were conducted using a patient-specific FE model loaded with seven sets of personalized muscle and hip joint contact force loading conditions estimated using a personalized neuromusculoskeletal (NMS) model. Predictions of fixation screw pullout and fatigue failure—quantified by simulated screw axial forces and von Mises stresses, respectively—were compared between analyses with and without personalized muscle forces. The study found that muscle forces had a considerable influence on predicted screw pullout but not fatigue failure. However, it remains unclear whether including or excluding muscle forces would yield more conservative predictions of screw failures. Furthermore, while the effect of muscle forces on predicted screw failures was location-dependent for cortical screws, no clear location dependency was observed for cancellous screws. These findings support the combined use of patient-specific FE and NMS models, including loading from muscle forces, when predicting screw pullout but not fatigue failure in custom pelvic implants.