John Edward Akin

Prof. Dr. John Edward Akin


Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2005 in Computers & Fluids
Verified
Journal Article
Closed access
JAJohn Edward Akin
John Edward Akin
TTTayfun E. Tezduyar
Tayfun E. Tezduyar
MUMehmet Ungor
Mehmet Ungor

13 October 2015 in Acta Mechanica
Verified
Journal Article
Closed access
PDF file
MFMohammad Ali Foyouzat
Mohammad Ali Foyouzat
MMMassod Mofid
Massod Mofid
JAJohn Edward Akin
John Edward Akin

19 August 2017 in Scientia Iranica
Verified
Journal Article
Open access
PDF file
SMSeyedemad Motaghian
Seyedemad Motaghian
MMMassod Mofid
Massod Mofid
JAJohn Edward Akin
John Edward Akin
In this research, the combination of Fourier sine series and Fourier cosine series is employed to develop an analytical method for free vibration analysis of an Euler-Bernoulli beam of varying cross- section, fully or partially supported by a variable elastic foundation. The foundation stiffness and cross section of the beam are considered as arbitrary functions in the beam length direction. The idea of the proposed method is to superpose Fourier sine and Fourier cosine series to satisfy general elastically end constraints and therefore no auxiliary functions are required to supplement the Fourier series. This method provides a simple, accurate and flexible solution for various beam problems and is also able to be extended to other cases whose governing differential equations are nonlinear. Moreover, this method is applicable for plate problems with different boundary conditions if two-dimensional Fourier sine and cosine series are taken as displacement function.Numerical examples are carried out illustrating the accuracy and efficiency of the presented approach.

12 November 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YZYuhui Zhu
Yuhui Zhu
ANAta Babazadeh Naseri
Ata Babazadeh Naseri
MBMatthew RW Brake
Matthew RW Brake
JAJohn Edward Akin
John Edward Akin
GLGeng Li
Geng Li
Benjamin FreglyBenjamin Fregly
Benjamin Fregly
Custom implants used for pelvic reconstruction in pelvic sarcoma surgery face a high complication rate due to mechanical failures of fixation screws. Consequently, patient-specific finite element (FE) models have been employed to analyze custom pelvic implant durability. However, muscle forces have often been omitted from FE studies of the post-operative pelvis with a custom implant, despite the lack of evidence that this omission has minimal impact on predicted bone, implant, and fixation screw stress distributions. This study investigated the influence of muscle forces on FE predictions of fixation screw pullout and fatigue failure in a custom pelvic implant. Specifically, FE analyses were conducted using a patient-specific FE model loaded with seven sets of personalized muscle and hip joint contact force loading conditions estimated using a personalized neuromusculoskeletal (NMS) model. Predictions of fixation screw pullout and fatigue failure—quantified by simulated screw axial forces and von Mises stresses, respectively—were compared between analyses with and without personalized muscle forces. The study found that muscle forces had a considerable influence on predicted screw pullout but not fatigue failure. However, it remains unclear whether including or excluding muscle forces would yield more conservative predictions of screw failures. Furthermore, while the effect of muscle forces on predicted screw failures was location-dependent for cortical screws, no clear location dependency was observed for cancellous screws. These findings support the combined use of patient-specific FE and NMS models, including loading from muscle forces, when predicting screw pullout but not fatigue failure in custom pelvic implants.

27 November 2001 in Computer Methods in Applied Mechanics and Engineering
Verified
Journal Article
Closed access
JAJohn Edward Akin
John Edward Akin
JBJ. Bass
J. Bass

9 March 2025 in Medical Engineering & Physics
Verified
Journal Article
Closed access
NDNicholas J. Dunbar
Nicholas J. Dunbar
YZYuhui Zhu
Yuhui Zhu
ANAta Babazadeh Naseri
Ata Babazadeh Naseri
JAJohn Edward Akin
John Edward Akin
BSBenedetta Spazzoli
Benedetta Spazzoli
Benjamin FreglyBenjamin Fregly
Benjamin Fregly
Additively manufactured, custom-made implants used for reconstruction are a promising treatment following tumor resection. However, failure rates due to mechanical factors remain high when used in the pelvis for even state-of-the-art prosthesis designs. In a collaborative effort between a clinical and an engineering research team, this study evaluated whether patient-specific biomechanical modeling could predict, in a blinded fashion, the mode and location of a clinically-observed mechanical failure. Multiple failure criteria were considered including the risk of bone fracture due to overloading or stress shielding and prosthesis fracture due to overloading or fatigue. The blinded predictions indicated that the risk of fatigue failure in the pubic screws were eight times higher than the most critical ilium screw and two times higher than the most critical cancellous screw. Simulation of stress-shielding during walking matched evidence of osteolysis in the ilium and pubis. Incorporating patient-specific modeling into the custom implant design process may lead to improved durability.