Paloma Martinez Alcaraz

Dr. Paloma Martinez Alcaraz


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PAPaloma Martinez Alcaraz
Paloma Martinez Alcaraz
Javier FloresJavier Flores
Javier Flores
Rubén Agustín PanaderoRubén Agustín Panadero
Rubén Agustín Panadero
GSGisela Senent-Vicente
Gisela Senent-Vicente
CGCristina Gómez-Polo
Cristina Gómez-Polo
ALAna Belén Lobo-Galindo
Ana Belén Lobo-Galindo
This study aimed to evaluate the retrievability and potential damage to implant–abutment connections caused by fractured abutment screw removal using conventional and drilling techniques. A total of forty abutment screws were randomly inserted into forty dental implants, and then they were fractured and extracted using different removal methods: Group A employed a conventional approach utilizing an exploration probe and an ultrasonic device without irrigation (n = 10) (conventional); Group B used the Phibo drilling removal system without irrigation (n = 10) (Phibo); Group C utilized the Rhein83® drilling removal system without irrigation (n = 10) (Rhein83); and Group D implemented the Sanhigia® drilling removal system without irrigation (n = 10) (Sanhigia). Pre- and postoperative micro-computed tomography (micro-CT) scans were performed on the dental implants, and Standard Tessellation Language (STL) digital files were generated for morphometric analysis to measure the wear volume. ANOVA was used to assess the volumetric differences (mm3) and percentage ratios of the internal thread volumes of the implant–abutment connections before and after the procedures. Results: This study found no statistically significant differences in the volumetric and percentage ratios of internal threads among the implant groups (Phibo, Rhein83, Sanhigia, and conventional). However, the success rate for retrieving fractured abutment screws was higher (90%) with the drilling systems compared to the conventional technique (50%). These results suggest that drilling systems are more effective for the retrieval of damaged screws. Although drilling techniques without irrigation demonstrated higher removal efficiency compared to the conventional method, both approaches resulted in similar wear volumes at the implant–abutment connections when used to extract fractured screws.

Verified
Journal Article
Open access
PDF file
SCSilvia de la Cruz-Jiménez
Silvia de la Cruz-Jiménez
PAPaloma Martinez Alcaraz
Paloma Martinez Alcaraz
Javier FloresJavier Flores
Javier Flores
Rubén Agustín PanaderoRubén Agustín Panadero
Rubén Agustín Panadero
ALAna Belén Lobo-Galindo
Ana Belén Lobo-Galindo
ÁZÁlvaro Zubizarreta-Macho
Álvaro Zubizarreta-Macho
The pontic design may influence the load-to-failure performance of fixed implant-supported screw-retained monolithic zirconia prostheses. This study aimed to evaluate the effect of pontic geometry on the fracture resistance of such restorations. Forty restorations were designed using dental CAD software and divided into four groups (n = 10 each): (A) Flat + Wide—pontics with a flat contour, 10 mm in width and 8 mm in height; (B) Concave + Wide—pontics with a concave contour, 10 mm in width and 5.5 mm in height; (C) Flat + Narrow—pontics with a flat contour, 6 mm in width and 8 mm in height; and (D) Concave + Narrow—pontics with a concave contour, 6 mm in width and 5.5 mm in height. All specimens underwent thermal and mechanical cycling, followed by a fracture load test using a three-point bending setup. Maximum fracture loads and displacements were analyzed using one-way ANOVA. Statistically significant differences were observed among the groups for both load to failure (p = 0.001) and displacement (p = 0.002). These findings indicate that pontic geometry significantly influences the fracture resistance and deformation behavior of monolithic zirconia prostheses.