Gibran Manasseh

Dr. Gibran Manasseh

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in Frontiers in Psychology
Verified
Journal Article
Open access
PDF file
GMGibran Manasseh
Gibran Manasseh
CBChloe de Balthasar
Chloe de Balthasar
BSBruno Sanguinetti
Bruno Sanguinetti
EPEnrico Pomarico
Enrico Pomarico
Nicolas GisinNicolas Gisin
Nicolas Gisin
SASara L. Gonzalez Andino
Sara L. Gonzalez Andino
The retina is one of the best known quantum detectors with rods able to reliably respond to single photons. However, estimates on the number of photons eliciting conscious perception, based on signal detection theory, are systematically above these values after discounting by retinal losses. One possibility is that there is a trade-off between the limited motor resources available to living systems and the excellent reliability of the visual photoreceptors. On this view, the limits to sensory thresholds are not set by the individual reliability of the receptors within each sensory modality (as often assumed) but rather by the limited central processing and motor resources available to process the constant inflow of sensory information. To investigate this issue, we reproduced the classical experiment from Hetch aimed to determine the sensory threshold in human vision. We combined a careful physical control of the stimulus parameters with high temporal/spatial resolution recordings of EEG signals and behavioral variables over a relatively large sample of subjects (12). Contrarily to the idea that the limits to visual sensitivity are fully set by the statistical fluctuations in photon absorption on retinal photoreceptors we observed that the state of ongoing neural oscillations before any photon impinges the retina helps to determine if the responses of photoreceptors have access to central conscious processing. Our results suggest that motivational and attentional off-retinal mechanisms play a major role in reducing the QE efficiency of the human visual system when compared to the efficiency of isolated retinal photoreceptors. Yet, this mechanism might subserve adaptive behavior by enhancing the overall multisensory efficiency of the whole system composed by diverse reliable sensory modalities.

18 October 2017 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
LCLindsey Crowe
Lindsey Crowe
GMGibran Manasseh
Gibran Manasseh
ACAneta Chmielewski
Aneta Chmielewski
AHAnne-Lise Hachulla
Anne-Lise Hachulla
DSDaniel Speicher
Daniel Speicher
RSRares V. Salomir
Rares V. Salomir
Objectives: We demonstrate the use of a Magnetic-Resonance (MR)-compatible ultrasound (US) imaging probe using spatially-resolved Doppler for diagnostic quality cardiovascular MR imaging as an initial step towards hybrid US/MR fetal imaging. Methods: A newly developed technology for a dedicated MR-compatible phased array ultrasound-imaging probe acquired pulsed color Doppler carotid images, which were converted in near-real time to a trigger signal for cardiac cine and flow quantification MRI. Ultrasound and MR data acquired simultaneously were interference free. Conventional ECG and the proposed spatially-resolved Doppler triggering were compared in 10 healthy volunteers. A synthetic éfalse-triggeredé image was retrospectively processed using Metric Optimized Gating (MOG). Images were scored by expert readers and sharpness, cardiac function and aortic flow were quantified. 4D flow (two volunteers) showed feasibility of Doppler triggering over a long acquisition time. Results. Imaging modalities were compatible. US probe positioning was stable and comfortable. Image quality scores and quantified sharpness were statistically equal for Doppler- and ECG-triggering (p=1.00). ECG-, Doppler-triggered and MOG ejection fractions were equivalent (p=1.00), with false-triggered values significantly lower (p0.05). 4D Flow quantification gave consistent results between ECG and Doppler triggering. Conclusion. We report interference-free pulsed color Doppler ultrasound during MR data acquisition. Cardiovascular MRI of diagnostic quality was successfully obtained with pulsed color Doppler triggering. Significance. The hardware platform could further enable advanced free-breathing cardiac imaging. Doppler ultrasound triggering is applicable where ECG is compromised due to pathology or interference at higher magnetic fields, and where direct ECG is impossible i.e. fetal imaging.

12 March 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
MGMarianna Gulizia
Marianna Gulizia
AVAnais Viry
Anais Viry
MJMario Jreige
Mario Jreige
Guillaume FahrniGuillaume Fahrni
Guillaume Fahrni
YMYannick Marro
Yannick Marro
NVNaïk Vietti-Violi
Naïk Vietti-Violi
Background/Objectives: To evaluate the feasibility of reducing contrast volume in oncologic body imaging using dual-energy CT (DECT) by (1) identifying the optimal virtual monochromatic imaging (VMI) reconstruction using DECT and (2) comparing DECT performed with reduced iodinated contrast media (ICM) volume to single-energy CT (SECT) performed with standard ICM volume. Methods: In this retrospective study, we quantitatively and qualitatively compared the image quality of 35 thoracoabdominopelvic DECT across 9 different virtual monoenergetic image (VMI) levels (from 40 to 80 keV) using a reduced volume of ICM (0.3 gI/kg of body weight) to determine the optimal keV reconstruction level. Out of these 35 patients, 20 had previously performed SECT with standard ICM volume (0.3 gI/kg of body weight + 9 gI), enabling protocol comparison. The qualitative analysis included overall image quality, noise, and contrast enhancement by two radiologists. Quantitative analysis included contrast enhancement measurements, contrast-to-noise ratio, and signal-to-noise ratio of the liver parenchyma and the portal vein. ANOVA was used to identify the optimal VMI level reconstruction, while t-tests and paired t-tests were used to compare both protocols. Results: VMI60 keV provided the highest overall image quality score. DECT with reduced ICM volume demonstrated higher contrast enhancement and lower noise than SECT with standard ICM volume (p < 0.001). No statistical difference was found in the overall image quality between the two protocols (p = 0.290). Conclusions: VMI60 keV with reduced contrast volume provides higher contrast and lower noise than SECT at a standard contrast volume. DECT using a reduced ICM volume is the technique of choice for oncologic body CT.

6 February 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
MGMarianna Gulizia
Marianna Gulizia
AVAnais Viry
Anais Viry
MJMario Jreige
Mario Jreige
Guillaume FahrniGuillaume Fahrni
Guillaume Fahrni
YMYannick Marro
Yannick Marro
NVNaïk Vietti-Violi
Naïk Vietti-Violi
Background/Objectives: To evaluate the feasibility of reducing contrast volume in oncologic body imaging using dual-energy CT (DECT) by (1) identifying the optimal virtual monochromatic imaging (VMI) reconstruction with DECT and (2) comparing DECT with reduced iodinated contrast media (ICM) volume to single-energy CT (SECT) with standard ICM volume. Methods: In this retrospective study, we quantitatively and qualitatively compared the image quality of 35 thoraco-abdominopelvic DECT across 9 different virtual monoenergetic image (VMI) levels (from 40 to 80 keV) using reduced volume of ICM (0.3gI/kg of body weight) to determine the optimal keV reconstruction level. Out of these 35 patients, 20 had previously performed SECT with standard ICM volume (0.3gI/kg of body weight + 9gI), enabling protocol comparison. Qualitative analysis included overall image quality, noise, and contrast enhancement by two radiologists. Quantitative analysis included contrast enhancement measurements, contrast-to-noise ratio and signal-to-noise ratio on liver parenchyma and portal vein. ANOVA identified the optimal VMI reconstruction, while t-tests and paired t-tests were used to compare both protocols. Results: VMI60keV provided the highest overall image quality score. DECT with reduced ICM volume demonstrated higher contrast enhancement and lower noise than SECT with standard ICM volume (p <0.001). No statistical difference was found in overall image quality between the two protocols (p = 0.290). Conclusions: VMI60keV with reduced contrast volume provides higher contrast and lower noise compared to SECT at standard contrast volume. DECT using reduced ICM volume is the technique of choice for oncologic body CT.

27 November 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
GMGibran Manasseh
Gibran Manasseh
THTom Hilbert
Tom Hilbert
MFMário João Fartaria
Mário João Fartaria
JDJeremy Deverdun
Jeremy Deverdun
MCMeritxell Bach Cuadra
Meritxell Bach Cuadra
Vincent DunetVincent Dunet
Vincent Dunet
Introduction: Lesion load (LL), deep gray matter (DGM) and normal-appearing white matter (NAWM) susceptibility and morphometry may help in monitoring brain changes in multiple sclerosis (MS) patients. We aimed at evaluating the feasibility of a fully automated segmentation and the potential interrelation between these biomarkers and clinical disability. Methods: Sixty-six patients with brain MRIs and clinical evaluations (Expanded Disability Status Scale [EDSS]) were retrospectively included. Automated prototypes were used for the segmentation and morphometry of brain regions (MorphoBox) and MS lesions (LeManPV). Susceptibility maps were estimated using standard post-processing (RESHARP and TVSB). Spearman’s rho was computed to evaluate the interrelation between biomarkers and EDSS. Results: We found (i) anticorrelations between the LL and right thalamus susceptibility (rho = −0.46, p < 0.001) and between the LL and NAWM susceptibility (rho = [−0.68 to −0.25], p ≤ 0.05); (ii) an anticorrelation between LL and DGM (rho = [−0.71 to −0.36], p < 0.04) and WM morphometry (rho = [−0.64 to −0.28], p ≤ 0.01); and (iii) a positive correlation between EDSS and LL (rho = [0.28 to 0.5], p ≤ 0.03) and anticorrelation between EDSS and NAWM susceptibility (rho = [−0.29 to −0.38], p < 0.014). Conclusions: Fully automated brain morphometry and susceptibility monitoring is feasible in MS patients. The lesion load, thalamus and NAWM susceptibility values and trophicity are interrelated and correlate with disability.