Daniel Speicher

Mr. Daniel Speicher

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MFMarc Fournelle
Marc Fournelle
TGTobias Grün
Tobias Grün
DSDaniel Speicher
Daniel Speicher
SWSteffen Weber
Steffen Weber
MYMehmet Yilmaz
Mehmet Yilmaz
HHHolger Hewener
Holger Hewener
We developed a new mobile ultrasound device for long-term and automated bladder monitoring without user interaction consisting of 32 transmit and receive electronics as well as a 32-element phased array 3 MHz transducer. The device architecture is based on data digitization and rapid transfer to a consumer electronics device (e.g., a tablet) for signal reconstruction (e.g., by means of plane wave compounding algorithms) and further image processing. All reconstruction algorithms are implemented in the GPU, allowing real-time reconstruction and imaging. The system and the beamforming algorithms were evaluated with respect to the imaging performance on standard sonographical phantoms (CIRS multipurpose ultrasound phantom) by analyzing the resolution, the SNR and the CNR. Furthermore, ML-based segmentation algorithms were developed and assessed with respect to their ability to reliably segment human bladders with different filling levels. A corresponding CNN was trained with 253 B-mode data sets and 20 B-mode images were evaluated. The quantitative and qualitative results of the bladder segmentation are presented and compared to the ground truth obtained by manual segmentation.

22 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CRChristoph Risser
Christoph Risser
HHHolger Hewener
Holger Hewener
MFMarc Fournelle
Marc Fournelle
HFHeinrich Fonfara
Heinrich Fonfara
SBSelina Barry-Hummel
Selina Barry-Hummel
STSteffen Tretbar
Steffen Tretbar
Volumetric ultrasound imaging is of great importance in many medical fields, especially in cardiology, but also in therapy monitoring applications. For development of new imaging technologies and scanning strategies, it is crucial to be able to use a hardware platform that is as free and flexible as possible and does not restrict the user in his research in any way. For this purpose, multi-channel ultrasound systems are particularly suitable, as they are able to control each individual element of a matrix array without the use of a multiplexer. We set out to develop a fully integrated, compact 1024-channel ultrasound system that provides full access to all transmission parameters and all digitized raw data of each transducer element. For this purpose, we synchronize four research scanners of our latest “DiPhAS” ultrasound research system generation, each with 256 parallel channels, all connected to a single PC on whose GPUs the entire signal processing is performed. All components of the system are housed in a compact, movable 19-inch rack. The system is designed as a general-purpose platform for research in volumetric imaging; however, the first-use case will be therapy monitoring by tracking radiation-sensitive ultrasound contrast agents.

18 October 2017 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
LCLindsey Crowe
Lindsey Crowe
GMGibran Manasseh
Gibran Manasseh
ACAneta Chmielewski
Aneta Chmielewski
AHAnne-Lise Hachulla
Anne-Lise Hachulla
DSDaniel Speicher
Daniel Speicher
RSRares V. Salomir
Rares V. Salomir
Objectives: We demonstrate the use of a Magnetic-Resonance (MR)-compatible ultrasound (US) imaging probe using spatially-resolved Doppler for diagnostic quality cardiovascular MR imaging as an initial step towards hybrid US/MR fetal imaging. Methods: A newly developed technology for a dedicated MR-compatible phased array ultrasound-imaging probe acquired pulsed color Doppler carotid images, which were converted in near-real time to a trigger signal for cardiac cine and flow quantification MRI. Ultrasound and MR data acquired simultaneously were interference free. Conventional ECG and the proposed spatially-resolved Doppler triggering were compared in 10 healthy volunteers. A synthetic éfalse-triggeredé image was retrospectively processed using Metric Optimized Gating (MOG). Images were scored by expert readers and sharpness, cardiac function and aortic flow were quantified. 4D flow (two volunteers) showed feasibility of Doppler triggering over a long acquisition time. Results. Imaging modalities were compatible. US probe positioning was stable and comfortable. Image quality scores and quantified sharpness were statistically equal for Doppler- and ECG-triggering (p=1.00). ECG-, Doppler-triggered and MOG ejection fractions were equivalent (p=1.00), with false-triggered values significantly lower (p0.05). 4D Flow quantification gave consistent results between ECG and Doppler triggering. Conclusion. We report interference-free pulsed color Doppler ultrasound during MR data acquisition. Cardiovascular MRI of diagnostic quality was successfully obtained with pulsed color Doppler triggering. Significance. The hardware platform could further enable advanced free-breathing cardiac imaging. Doppler ultrasound triggering is applicable where ECG is compromised due to pathology or interference at higher magnetic fields, and where direct ECG is impossible i.e. fetal imaging.

2 February 2023 in Cells
Verified
Journal Article
Open access
PDF file
XZXinrui Zhang
Xinrui Zhang
SGSebastian Greiser
Sebastian Greiser
URUpasana Roy
Upasana Roy
FLFranziska Lange
Franziska Lange
RGRobbert van Gorkum
Robbert van Gorkum
LLLisa Landgraf
Lisa Landgraf
Focused ultrasound (FUS) can be used to physiologically change or destroy tissue in a non-invasive way. A few commercial systems have clinical approval for the thermal ablation of solid tumors for the treatment of neurological diseases and palliative pain management of bone metastases. However, the thermal effects of FUS are known to lead to various biological effects, such as inhibition of repair of DNA damage, reduction in tumor hypoxia, and induction of apoptosis. Here, we studied radiosensitization as a combination therapy of FUS and RT in a xenograft mouse model using newly developed MRI-compatible FUS equipment. Xenograft tumor-bearing mice were produced by subcutaneous injection of the human prostate cancer cell line PC-3. Animals were treated with FUS in 7 T MRI at 4.8 W/cm2 to reach ~45 °C and held for 30 min. The temperature was controlled via fiber optics and proton resonance frequency shift (PRF) MR thermometry in parallel. In the combination group, animals were treated with FUS followed by X-ray at a single dose of 10 Gy. The effects of FUS and RT were assessed via hematoxylin-eosin (H&E) staining. Tumor proliferation was detected by the immunohistochemistry of Ki67 and apoptosis was measured by a TUNEL assay. At 40 days follow-up, the impact of RT on cancer cells was significantly improved by FUS as demonstrated by a reduction in cell nucleoli from 189 to 237 compared to RT alone. Inhibition of tumor growth by 4.6 times was observed in vivo in the FUS + RT group (85.3%) in contrast to the tumor volume of 393% in the untreated control. Our results demonstrated the feasibility of combined MRI-guided FUS and RT for the treatment of prostate cancer in a xenograft mouse model and may provide a chance for less invasive cancer therapy through radiosensitization.

25 March 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DSDaniel Speicher
Daniel Speicher
TGTobias Grün
Tobias Grün
SWSteffen Weber
Steffen Weber
HHHolger Hewener
Holger Hewener
SKStephan Klesy
Stephan Klesy
MFMarc Fournelle
Marc Fournelle
Reliable acoustic coupling in a non-handheld mode and reducing the form factor of electronics are specific challenges in making ultrasound wearable. Applications relying on a large field of view (such as tracking of large muscles) induce a need for a large element count to achieve high image quality. In our work, we developed a 256-element linear array for imaging of abdominal muscles with four integrated custom-developed 8:32 multiplexer Integrated Circuits (ICs), allowing the array to be driven by our compact 32 ch electronics. The system is optimized for flexible use in R&D applications and allows adjustable transmit voltages (up to +/−100 V), arbitrary delay patterns, and 12-bit analog-to-digital conversion (ADC) with up to 50 MSPS and wireless (21.6 MBit/s) or USB link. Image metrics (SLL, FWHM) were very similar to a fully populated array driven with a 256 ch system. The contrast allowed imaging of lesions down to 7 cm in the phantom. In a first in-vivo study, we demonstrated reliable acoustic contact even during exercise and were able to visualize deep abdominal muscles such as the TrA. In combination with a muscle tracking algorithm, the change of thickness of the TrA during SSE could be monitored, demonstrating the potential of the approach as biofeedback for physiotherapy training.