Andre Luis Luis Razera

Dr. Andre Luis Luis Razera

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2024 in Fluids
Verified
Journal Article
Open access
PDF file
IAIvanilton Reinato De Andrede
Ivanilton Reinato De Andrede
Elizaldo dos SantosElizaldo dos Santos
Elizaldo dos Santos
HZHalley Zhang
Halley Zhang
LRLuiz Alberto Oliveira Rocha
Luiz Alberto Oliveira Rocha
ARAndre Luis Luis Razera
Andre Luis Luis Razera
Liércio André IsoldiLiércio André Isoldi
Liércio André Isoldi
This study presents a numerical evaluation of a Horizontal Rectilinear Earth–air Heat Exchanger (EAHE), considering the climatic and soil conditions of Viamão, Brazil, a subtropical region. The Constructal Design method, combined with the Exhaustive Search, was utilized to define the system constraints, degree of freedom, and performance indicators. The degree of freedom was characterized by the aspect ratio between the vertical and horizontal lengths of the elliptical cross-section duct (H/L). The performance indicators for the EAHE configurations were assessed based on thermal potential (TP) and pressure drop (PD). The Technique for Order Preference by Similarity to Ideal Solution (TOPSIS) was applied for multi-objective evaluation, and a methodology for EAHE is proposed. The problem was solved using FLUENT software (version 2024 R2), which employs the Finite Volume Method to solve the conservation equations for mass, momentum, and energy. The (H/L)T,o = 6.0 configuration showed a 16.4% increase in thermal performance for heating and 15.9% for cooling compared to the conventional circular duct. Conversely, the (H/L)F,o = 1.0 configuration reduced pressure loss by 65.33%. The integration of Constructal Design with TOPSIS facilitated the identification of optimized geometries that achieve a balance between performance indicators and those that specifically prioritize thermal or fluid dynamic aspects, being this approach an original scientific contribution of the present work.

28 November 2025 in Fluids
Verified
Journal Article
Open access
PDF file
GVGiovanni Antonio Vielma Vivas
Giovanni Antonio Vielma Vivas
ZRZurisaday Colonico Reyes
Zurisaday Colonico Reyes
ARAndre Luis Luis Razera
Andre Luis Luis Razera
LRLuiz Alberto Oliveira Rocha
Luiz Alberto Oliveira Rocha
Elizaldo dos SantosElizaldo dos Santos
Elizaldo dos Santos
Liércio André IsoldiLiércio André Isoldi
Liércio André Isoldi
This study evaluates the impact of integrating Phase Change Materials (PCMs) in the efficiency of Ground-Air Heat Exchangers (GAHEs). A three-dimensional computational model for the GAHE system with an integrated annular PCM (GAHE-PCM) was implemented in ANSYS Fluent using the Finite Volume Method, accounting for the meteorological conditions and ground properties of Viamão, Brazil. A parametric evaluation with fifteen rectangular and fifteen elliptical PCM container configurations were analyzed by varying their geometric ratios. Results indicate that the inclusion of PCM may enhance the yearly thermal potential as high as 69.31% in heating and 27.92% in cooling. Geometries, such as square or circular cross-sections, maximize heat exchange with the airflow, whereas elongated shapes reduce PCM efficiency. Furthermore, placing most of the PCM in deeper, thermally stable soil layers reduces the overall performance. For near-optimal designs, the differences between rectangular and elliptical containers are minimal, providing flexibility for system implementation.

3 January 2026 in Geothermics
Verified
Journal Article
Closed access
ADAna M.B. Domingues
Ana M.B. Domingues
ARAndre Luis Luis Razera
Andre Luis Luis Razera
JRJairo V.A. Ramalho
Jairo V.A. Ramalho
MRMichel K. Rodrigues
Michel K. Rodrigues
HFHonório J. Fernando
Honório J. Fernando
Elizaldo dos SantosElizaldo dos Santos
Elizaldo dos Santos

30 July 2026 in Thermal Science and Engineering Progress
Verified
Journal Article
Open access
ZRZurisaday Colonico Reyes
Zurisaday Colonico Reyes
GVGiovanni Antonio Vielma Vivas
Giovanni Antonio Vielma Vivas
RBRuth da Silva Brum
Ruth da Silva Brum
EEEmanuel da Silva Diaz Estrada
Emanuel da Silva Diaz Estrada
LRLuiz Alberto Oliveira Rocha
Luiz Alberto Oliveira Rocha
LILiércio André Isoldi
Liércio André Isoldi

1 March 2026 in Journal of Engineering Thermophysics
Verified
Journal Article
Closed access
PDF file
MMM. Moreira
M. Moreira
VMVitor Eduardo Motta
Vitor Eduardo Motta
ARAndre Luis Luis Razera
Andre Luis Luis Razera
MGMateus Gomes
Mateus Gomes
Bianca Neves MachadoBianca Neves Machado
Bianca Neves Machado
Liércio André IsoldiLiércio André Isoldi
Liércio André Isoldi
Developing clean energy technologies to harness ocean waves remains a key engineering challenge. In this context, the influence of geometry on the performance of an oscillating water column (OWC) wave energy converter through the Constructal Design method is investigated. The objective is to maximize available hydropneumatic power when the system is subjected to full-scale regular waves. An inclined plate apparatus was inserted at the bottom of the OWC to evaluate its performance at inclinations of 0°, 20°, 40°, 60°, 80°, and 90° relative to the vertical direction. A validated and verified computational model based on the finite volume method was employed. The multiphase volume of fluid model was applied to handle air–water interaction. Results showed that the highest hydropneumatic power was achieved at 80°, which is 30.47% superior than the worst case with 0°.

8 April 2026 in Revista Mundi Engenharia, Tecnologia e Gestão (ISSN: 2525-4782)
Verified
Journal Article
Open access
ARAndre Luis Luis Razera
Andre Luis Luis Razera
IVIgor Silva Vaz
Igor Silva Vaz
MRMichel Kepes Rodrigues
Michel Kepes Rodrigues
MMMauricio Da Silva Moreira
Mauricio Da Silva Moreira
LRLuiz Alberto Oliveira Rocha
Luiz Alberto Oliveira Rocha
Liércio André IsoldiLiércio André Isoldi
Liércio André Isoldi
O presente trabalho tem por objetivo avaliar numericamente um Trocador de Calor Solo-Ar Horizontal Helicoidal (TCSA-HH), considerando características climáticas e do solo do município de Viamão, RS, Brasil. A geometria do sistema é avaliada por meio da variação do passo entre as helicoides (Ph) do TCSA. O parâmetro utilizado para a análise do desempenho das diferentes configurações do TCSA-HH é através da avaliação do potencial térmico (PT) do sistema. O problema é solucionado numericamente utilizando o software FLUENT, que emprega o Método dos Volumes Finitos para resolver as equações de conservação de massa, quantidade de movimento e energia. Como resultado, os TCSAs-HH mostram-se apropriados para resfriamento do ar durante períodos quentes, embora a capacidade de aquecimento se apresente irrelevante em períodos frios. O TCSA-HH com Ph = 100 mm obteve o melhor desempenho relacionado ao PT, superando em aproximadamente 10% o TCSA-HH com Ph = 400 mm, que apresentou o pior desempenho térmico. Comparado a outros TCSAs presentes na literatura, o TCSA-HH apresentou um desempenho similar para condição de resfriamento, demonstrando ser uma alternativa viável para terrenos compactos.