Currently, microscopic research on the tensile fracture properties of recycled brick coarse aggregate concrete has mainly adopted microscopy techniques, which can clearly observe the actual damage situations of each phase material but are unable to individually analyze the effect of a specific material factor on the tensile properties of recycled concrete. This brings much uncertainty to the practical application of recycled concrete. Therefore, this study proposes a cohesive zone model (CZM) for simulating the tensile fracture of recycled brick coarse aggregate (RBCA) concrete. To this end, the study explores the effects of various critical factors on the fracture mode and bearing capacity of recycled brick aggregate concrete, including the replacement rate of recycled brick coarse aggregate, pore structure, interfacial transition zone (ITZ) strength, mortar strength, and volume fraction of brick aggregate. The results indicate that, when the minor to major axis ratio of elliptical pores is 0.5 ≤ K < 1, the following order of influence can be observed: random convex polygonal pores, circular pores, and elliptical pores. Moreover, excessively strengthening the ITZ and mortar does not significantly enhance the tensile performance of RBCA concrete. The distribution location of aggregate has a significant impact on the crack shape of recycled concrete, as does the pore structure, due to their randomness. Therefore, this article also discusses these. These findings contribute to a comprehensive understanding of the tensile properties of recycled brick coarse aggregate and provide insights into optimizing its behavior.
(1) Background: In most cases, passive isolation control methods are commonly used for the seismic isolation design in bridge engineering. However, passive seismic isolation devices, due to their non-adjustable performance parameters, struggle to achieve effective seismic isolation across a wide frequency range of 0 Hz to 20 Hz in response to random and varying seismic loads. (2) Methods: The sensitivity of the design parameters of the seismic isolation bearing was analyzed using the optimization center gradient method, and an improved genetic algorithm was employed to quickly optimize and obtain the optimal design parameters. (3) Results: The effectiveness of the three-dimensional seismic isolation bearing was validated through experiments. (4) Conclusions: The multi-factor sensitivity analysis approach used in this study for designing novel isolation bearings is applicable not only to seismic design in bridges but also serves as a reference for parameter design in isolation bearings requiring medium to high precision in seismic performance.
A bridge hybrid isolation system, integrating both active and passive control strategies, is proposed and investigated to enhance seismic performance. The system is modeled as a two-layer structure, with the upper layer subjected to active control via a Proportional–Integral–Derivative (PID) controller, and the lower layer employing a conventional passive base isolation system. The displacement response of the superstructure is minimized by the control forces generated by the PID controller, which also accounts for the reaction forces transmitted to the lower isolation layer. To optimize the controller’s performance, a genetic algorithm is implemented for real-time tuning of the PID parameters. Numerical simulations, conducted using the Newmark method, are employed to assess the influence of active control on the lower isolation system. The results reveal that, while active control increases the peak displacement of the superstructure to some extent, it significantly prolongs the structural period, thus enhancing the system’s overall seismic resilience and stability.
(1) Background: In most cases, passive isolation control methods are commonly used for the seismic isolation design of bridge engineering. However, for passive seismic isolation devices, due to their non-adjustable performance parameters, it is challenging to achieve a good seismic isolation effect for structures under random and variable seismic loads in the wide frequency range of 0 Hz to 20 Hz; (2) Methods: the sensitivity of the design parameters of the seismic isolation bearing was analyzed using the optimization center gradient method, and an improved genetic algorithm was employed to quickly optimize and obtain the optimal design parameters; (3) Results: the effectiveness of the three-dimensional seismic isolation bearing was validated through experiments. (4) Conclusions: The multi-factor sensitivity analysis approach used in this study for designing novel isolation bearings is applicable not only to seismic design in bridges but also serves as a reference for parameter design in isolation bearings requiring medium to high precision in seismic performance.
Glass fiber-reinforced polymer (GFRP) connecting joints are difficult in the design of structural components and also critical areas prone to damage. In this study, based on the existing research, a combination of experimental and finite element analysis is used to systematically analyze the performance-influencing factors of the hybrid connection of glass fiber-reinforced composite plate and steel plate adhesive bolts under tension. By discussing the damage modes, load–displacement curves, and strain distributions at the GFRP connection joints, the influence of the connection methods and bolt quantities on the tensile properties of double-lap joints comprising GFRP plates and steel plates is revealed, and a loss evolution model for GFRP composite plates is established based on the Hashin failure criterion. The results show that the adhesive–bolted connection integrates the advantages of both adhesive bonding and bolted connections, significantly improving the tensile performance of the joint. Furthermore, the vertical arrangement of two bolts is superior to the horizontal arrangement under double-bolt connection conditions between GFRP plates and steel plates. For the several design options proposed in this study, the GFRP joints exhibit the optimal tensile properties among the four bolt arrangement schemes.