Kim Kim

Dr. Kim Kim


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 April 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
KKKim Kim
Kim Kim
Beanbonyka RimBeanbonyka Rim
Beanbonyka Rim
SCSeong Jun Choi
Seong Jun Choi
Ahyoung LeeAhyoung Lee
Ahyoung Lee
Se Dong MinSe Dong Min
Se Dong Min
MHMin Hong
Min Hong
Chest X-ray radiographic (CXR) imagery enables earlier and easier lung disease diagnosis. Therefore, in this paper, we propose a deep learning method using a transfer learning technique to classify lung diseases on CXR images to improve the efficiency and accuracy of computer-aided diagnostic systems’ (CADs’) diagnostic performance. Our proposed method is a one-step, end-to-end learning, which means that raw CXR images are directly inputted into a deep learning model (EfficientNet v2-M) to extract their meaningful features in identifying disease categories. We experimented using our proposed method on three classes of normal, pneumonia, and pneumothorax of the U.S. National Institutes of Health (NIH) data set, and achieved validation performances of loss = 0.6933, accuracy = 82.15%, sensitivity = 81.40%, and specificity = 91.65%. We also experimented on the Cheonan Soonchunhyang University Hospital (SCH) data set on four classes of normal, pneumonia, pneumothorax, and tuberculosis, and achieved validation performances of loss = 0.7658, accuracy = 82.20%, sensitivity = 81.40%, and specificity = 94.48%; testing accuracy of normal, pneumonia, pneumothorax, and tuberculosis classes was 63.60%, 82.30%, 82.80%, and 89.90%, respectively.

12 June 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
JMJun Ma
Jun Ma
SCSeong Jun Choi
Seong Jun Choi
KKKim Kim
Kim Kim
MHMin Hong
Min Hong
This study evaluates the efficacy of several Convolutional Neural Network (CNN) models for the classification of hearing loss in patients using preprocessed auditory brainstem response (ABR) image data. Specifically, we employed six CNN architectures—VGG16, VGG19, DenseNet121, DenseNet-201, AlexNet, and InceptionV3—to differentiate between patients with hearing loss and those with normal hearing. A dataset comprising 7990 preprocessed ABR images was utilized to assess the performance and accuracy of these models. Each model was systematically tested to determine its capability to accurately classify hearing loss. A comparative analysis of the models focused on metrics of accuracy and computational efficiency. The results indicated that the AlexNet model exhibited superior performance, achieving an accuracy of 95.93%. The findings from this research suggest that deep learning models, particularly AlexNet in this instance, hold significant potential for automating the diagnosis of hearing loss using ABR graph data. Future work will aim to refine these models to enhance their diagnostic accuracy and efficiency, fostering their practical application in clinical settings.

15 October 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SSShin Jae sung
Shin Jae sung
JMJun Ma
Jun Ma
SCSeong Jun Choi
Seong Jun Choi
KKKim Kim
Kim Kim
MHMin Hong
Min Hong
Speech audiometry is a vital tool in assessing an individual’s ability to perceive and comprehend speech, traditionally requiring specialized testing that can be time-consuming and resource -intensive. This paper approaches a novel use of deep learning to predict speech audiometry using pure-tone audiometry (PTA) data. By utilizing PTA data, which measure hearing sensitivity at specific frequencies, we aim to develop a model that can bypass the need for direct speech testing. This study investigates two neural network architectures: a multi-layer perceptron (MLP) and a one-dimensional convolutional neural network (1D-CNN). These models are trained to predict key speech audiometry outcomes, including speech recognition thresholds and speech discrimination scores. To evaluate the effectiveness of these models, we employed two key performance metrics: the coefficient of determination (R2) and mean absolute error (MAE). The MLP model demonstrated predictive solid power with an R2 score of 88.79% and an average MAE of 7.26, while the 1D-CNN model achieved a slightly higher level of accuracy with an MAE score of 88.35% and an MAE of 6.90. The superior performance of the 1D-CNN model suggests that it captures relevant features from PTA data more effectively than the MLP. These results show that both models hold promise for predicting speech audiometry, potentially simplifying the audiological evaluation process. This approach is applied in clinical settings for hearing loss assessment, the selection of hearing aids, and the development of personalized auditory rehabilitation programs.

12 March 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SSShin Jae sung
Shin Jae sung
JMJun Ma
Jun Ma
Makara MaoMakara Mao
Makara Mao
NSNak-Jun Sung
Nak-Jun Sung
SCSeong Jun Choi
Seong Jun Choi
MHMin Hong
Min Hong
Hearing loss significantly impacts daily communication, making accurate speech audiometry (SA) assessment essential for diagnosis and treatment. However, SA testing is time-consuming and resource-intensive, limiting its accessibility in clinical practice. This study aimed to develop a multi-class classification model that predicts SA results using pure-tone audiometry (PTA) data, enabling a more efficient and automated assessment. To achieve this, we implemented and compared MLP, RNN, gradient boosting, and XGBoost models, evaluating their performance using accuracy, F1 score, log loss, and confusion matrix analysis. Experimental results showed that gradient boosting achieved the highest accuracy, 86.22%, while XGBoost demonstrated a more balanced classification performance. The MLP achieved 85.77% and the RNN achieved 85.41%, exhibiting relatively low accuracy, with the RNN showing limitations due to the low temporal dependency of PTA data. Additionally, all models faced challenges predicting class 2 (borderline hearing levels) due to overlapping data distributions. These findings suggest that machine learning models, particularly gradient boosting and XGBoost, outperform deep learning models in SA prediction. Future research should focus on feature engineering, hyperparameter optimization, and ensemble approaches to enhance performance and validate real-world applicability. The proposed model could contribute to automating SA prediction and improving hearing assessment efficiency and patient care.