Se Dong Min

Prof. Se Dong Min

Soonchunhyang University, Cheonan, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Beanbonyka RimBeanbonyka Rim
Beanbonyka Rim
NSNak-Jun Sung
Nak-Jun Sung
Se Dong MinSe Dong Min
Se Dong Min
MHMin Hong
Min Hong
Deep Learning (DL), a successful promising approach for discriminative and generative tasks, has recently proved its high potential in 2D medical imaging analysis; however, physiological data in the form of 1D signals have yet to be beneficially exploited from this novel approach to fulfil the desired medical tasks. Therefore, in this paper we survey the latest scientific research on deep learning in physiological signal data such as electromyogram (EMG), electrocardiogram (ECG), electroencephalogram (EEG), and electrooculogram (EOG). We found 147 papers published between January 2018 and October 2019 inclusive from various journals and publishers. The objective of this paper is to conduct a detailed study to comprehend, categorize, and compare the key parameters of the deep-learning approaches that have been used in physiological signal analysis for various medical applications. The key parameters of deep-learning approach that we review are the input data type, deep-learning task, deep-learning model, training architecture, and dataset sources. Those are the main key parameters that affect system performance. We taxonomize the research works using deep-learning method in physiological signal analysis based on: (1) physiological signal data perspective, such as data modality and medical application; and (2) deep-learning concept perspective such as training architecture and dataset sources.

13 September 2010 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Se Dong MinSe Dong Min
Se Dong Min
JKJin Kwon Kim
Jin Kwon Kim
Hangsik ShinHangsik Shin
Hangsik Shin
YYYong Hyeon Yun
Yong Hyeon Yun
CLChung Keun Lee
Chung Keun Lee
MLMyoungho Lee
Myoungho Lee
This research presents the ultrasonic proximity sensor approach to respiration measurement. The ultrasonic proximity sensor measures respiration signatures and rates in real-time and for long-term monitoring, which is necessary for mobility from the end-user perspective. The study used a 240 kHz ultrasonic sensor to measure the time of flight of a sound wave between the transmitted signal and received signal during respiration in the abdominal wall-motion. Respiration rates measured with the ultrasonic proximity sensor were then compared with those measured with a thermocouple sensor on ten male subjects. Data from the measurement of respiration rates at 100 cm is provided. We have used this data from the method comparison study to confirm agreement with the reference signal to determine that the current version of respiratory rate detection system using ultrasonic can successfully measure respiration rates. The proposed respiratory measurement method could be used to monitor an unconscious person without the need to apply electrodes or other sensors in the correct position and to wire the subject to the system. Monitoring respiration using ultrasonic sensor offers a promising possibility of noncontact measurement of respiration rates. In particular, this technology offers a potentially inexpensive means to extend applications to consumer home-healthcare and mobile-healthcare products. Further advances in the sensor design, system design and signal processing can increase the range and quality of the measurement, broadening the potential application areas of this technology.

6 April 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
KKKim Kim
Kim Kim
Beanbonyka RimBeanbonyka Rim
Beanbonyka Rim
SCSeong Jun Choi
Seong Jun Choi
Ahyoung LeeAhyoung Lee
Ahyoung Lee
Se Dong MinSe Dong Min
Se Dong Min
MHMin Hong
Min Hong
Chest X-ray radiographic (CXR) imagery enables earlier and easier lung disease diagnosis. Therefore, in this paper, we propose a deep learning method using a transfer learning technique to classify lung diseases on CXR images to improve the efficiency and accuracy of computer-aided diagnostic systems’ (CADs’) diagnostic performance. Our proposed method is a one-step, end-to-end learning, which means that raw CXR images are directly inputted into a deep learning model (EfficientNet v2-M) to extract their meaningful features in identifying disease categories. We experimented using our proposed method on three classes of normal, pneumonia, and pneumothorax of the U.S. National Institutes of Health (NIH) data set, and achieved validation performances of loss = 0.6933, accuracy = 82.15%, sensitivity = 81.40%, and specificity = 91.65%. We also experimented on the Cheonan Soonchunhyang University Hospital (SCH) data set on four classes of normal, pneumonia, pneumothorax, and tuberculosis, and achieved validation performances of loss = 0.7658, accuracy = 82.20%, sensitivity = 81.40%, and specificity = 94.48%; testing accuracy of normal, pneumonia, pneumothorax, and tuberculosis classes was 63.60%, 82.30%, 82.80%, and 89.90%, respectively.

10 January 2017 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
Hangsik ShinHangsik Shin
Hangsik Shin
Se Dong MinSe Dong Min
Se Dong Min
Blood pressure is a critical bio-signal and its importance has been increased with the aged society and the growth of cardiovascular disease population. However, most of hypertensive patients have been suffered the inconvenience in monitoring blood pressure in daily life because the measurement of the blood pressure depends on the cuff-based technique. Nowadays there are many trials to measure blood pressure without cuff, especially, photoplethysmography (PPG) based research is carried out in various ways. Our research is designed to hypothesis the relationship between vessel wall movement and pressure-flow relationship of PPG and to validate its appropriateness by experimental methods. PPG waveform is simplified by approximate model, and then it is analyzed as the velocity and the acceleration of blood flow using the derivatives of PPG. Finally, we develop pressure index (PI) as an estimation factor of blood pressure by combining of statistically significant segments of photoplethysmographic waveform. Twenty-five subjects were participated in the experiment. As a result of simulation, correlation coefficients between developed PI and blood pressure were represented with R = 0.818, R = 0.827 and R = 0.615 in systolic blood pressure, pulse pressure and mean arterial pressure, respectively, and both of result showed the meaningful statistically significance (P < 0.05). Current study can estimate only the relative variation of blood pressure but could not find the absolute pressure value. Moreover, proposed index has the limitation of diastolic pressure tracing. However, the result shows that the proposed PI is statistically significantly correlated with blood pressures, and it suggests that the proposed PI as a promising additional parameter for the cuff less blood pressure monitoring.

17 June 2014 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Se Dong MinSe Dong Min
Se Dong Min
YYYonghyeon Yun
Yonghyeon Yun
Hangsik ShinHangsik Shin
Hangsik Shin
We propose a simplified structural textile capacitive respiration sensor (TCRS) for respiration monitoring system. The TCRS is fabricated with conductive textile and Polyester, and it has a simple layered architecture. We derive the respiration by the distance changes between two textile plates in the TCRS, which measures the force from the abdominal diameter changes with the respiratory movement. To evaluate the reliability of TCRS, both linearity test and comparison test were carried out. Three times of tensile experiment were performed to confirm the linearity of change in capacitance by the distance change. The result shows that the coefficient of determination (R 2 ) of proposed TCRS is 0.9933. For comparative study, 16 subjects were participating in the experiment. As a result, the proposed respiratory rate detection system using TCRS successfully measures respiration compared with nasal airflow detection (R = 0.9846, p <; 0.001). In Bland-Altman analysis, the upper limit agreement is 0.5018 respirations per minute and lower limit of the agreement is -0.5049 respirations per minute. From these results, we confirmed that the TCRS could be used for monitoring of unconscious persons, avoiding the uncomfortness of subjects. Monitoring respiration using TCRS offers a promising possibility of convenient measurement of respiration rates. In particular, this technology offers a potentially inexpensive implementation that could extend applications to consumer home-healthcare and mobile-healthcare products.

26 November 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SKSungHun Kim
SungHun Kim
Changwon WangChangwon Wang
Changwon Wang
Se Dong MinSe Dong Min
Se Dong Min
SLSeung-Hyun Lee
Seung-Hyun Lee
In the Korean construction industry, legal and institutional safety management improvements are continually being pursued. However, there was a 4.5% increase in the number of workers’ deaths at construction sites in 2017 compared to the previous year. Failure to wear safety helmets seems to be one of the major causes of the increase in accidents, and so it is necessary to develop technology to monitor whether or not safety helmets are being used. However, the approaches employed in existing technical studies on this issue have mainly involved the use of chinstrap sensors and have been limited to the problem of whether or not safety helmets are being worn. Meanwhile, improper wearing, such as when the chinstrap and harness fixing of the safety helmet are not properly tightened, has not been monitored. To remedy this shortcoming, a sensing safety helmet with a three-axis accelerometer sensor attached was developed in this study. Experiments were performed in which the sensing data were classified whether the safety helmet was being worn properly, not worn, or worn improperly during construction workers’ activities. The results verified that it is possible to differentiate among wearing status of the proposed safety helmet with a high accuracy of 97.0%.