Nicholas Kyriakides

Dr. Nicholas Kyriakides

Department of Civil Engineering and Geomatics, Cyprus University of Technology, Achilleos 1 Building, 2nd floor, office 214, Saripolou 2-8, 3036, Limassol, Cyprus

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2014 in Engineering Structures
Verified
Journal Article
Closed access
Panagiotis G. AsterisPanagiotis G. Asteris
Panagiotis G. Asteris
MCM.P. Chronopoulos
M.P. Chronopoulos
CCC.Z. Chrysostomou
C.Z. Chrysostomou
Humberto VarumHumberto Varum
Humberto Varum
Vagelis PlevrisVagelis Plevris
Vagelis Plevris
Vitor SilvaVitor Silva
Vitor Silva

24 January 2014 in Journal of Earthquake Engineering
Verified
Journal Article
Open access
Reyes GarciaReyes Garcia
Reyes Garcia
Iman HajirasoulihaIman Hajirasouliha
Iman Hajirasouliha
MGMaurizio Guadagnini
Maurizio Guadagnini
YHYasser Helal
Yasser Helal
YJYaser Jemaa
Yaser Jemaa
MSM. Saiidi
M. Saiidi
The effectiveness of a novel Post-Tensioned Metal Strapping (PTMS) technique at enhancing the seismic behavior of a substandard RC building was investigated through full-scale, shake-table tests during the EU-funded project BANDIT. The building had inadequate reinforcement detailing in columns and joints to replicate old construction practices. After the bare building was initially damaged significantly, it was repaired and strengthened with PTMS to perform additional seismic tests. The PTMS technique improved considerably the seismic performance of the tested building. While the bare building experienced critical damage at an earthquake of PGA = 0.15 g, the PTMS-strengthened building sustained a PGA = 0.35 g earthquake without compromising stability.

1 September 2020 in Construction and Building Materials
Verified
Journal Article
Closed access
Thomaida PolydorouThomaida Polydorou
Thomaida Polydorou
GCGeorgios Constantinides
Georgios Constantinides
KNKyriacos Neocleous
Kyriacos Neocleous
NKNicholas Kyriakides
Nicholas Kyriakides
LKLoukas Koutsokeras
Loukas Koutsokeras
DHDiofantos Hadjimitsis
Diofantos Hadjimitsis

1 December 2012 in Soil Dynamics and Earthquake Engineering
Verified
Journal Article
Closed access
RVRenos A. A Votsis
Renos A. A Votsis
NKNicholas Kyriakides
Nicholas Kyriakides
CCChristis Z. Chrysostomou
Christis Z. Chrysostomou
ETElia Tantele
Elia Tantele
TDThemos Demetriou
Themos Demetriou

1 August 2015 in Bulletin of Earthquake Engineering
Verified
Journal Article
Closed access
PDF file
Reyes GarciaReyes Garcia
Reyes Garcia
KPKypros Pilakoutas
Kypros Pilakoutas
Iman HajirasoulihaIman Hajirasouliha
Iman Hajirasouliha
MGMaurizio Guadagnini
Maurizio Guadagnini
NKNicholas Kyriakides
Nicholas Kyriakides
Mihaela Anca CiupalaMihaela Anca Ciupala
Mihaela Anca Ciupala

29 April 2021 in International Journal of Concrete Structures and Materials
Verified
Journal Article
Open access
PDF file
FWFayu Wang
Fayu Wang
NKNicholas Kyriakides
Nicholas Kyriakides
CCChristis Chrysostomou
Christis Chrysostomou
EEEleftherios Eleftheriou
Eleftherios Eleftheriou
RVRenos A. A Votsis
Renos A. A Votsis
RIRogiros Illampas
Rogiros Illampas
Fabric reinforced cementitious matrix (FRCM) composites, also known as textile reinforced mortars (TRM), an inorganic matrix constituting fibre fabrics and cement-based mortar, are becoming a widely used composite material in Europe for upgrading the seismic resistance of existing reinforced concrete (RC) frame buildings. One way of providing seismic resistance upgrading is through the application of the proposed FRCM system on existing masonry infill walls to increase their stiffness and integrity. To examine the effectiveness of this application, the bond characteristics achieved between (a) the matrix and the masonry substrate and (b) the fabric and the matrix need to be determined. A series of experiments including 23 material performance tests, 15 direct tensile tests of dry fabric and composites, and 30 shear bond tests between the matrix and brick masonry, were carried out to investigate the fabric-to-matrix and matrix-to-substrate bond behaviour. In addition, different arrangements of extruded polystyrene (XPS) plates were applied to the FRCM to test the shear bond capacity of this insulation system when used on a large-scale wall.