Xu Feng

Mr. Xu Feng


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2025 in Buildings
Verified
Journal Article
Open access
PDF file
XFXu Feng
Xu Feng
YCYuliang Cai
Yuliang Cai
FWFei Wang
Fei Wang
ZLZhongda Lv
Zhongda Lv
WYWei Yang
Wei Yang
LWLei Wang
Lei Wang
Large precast concrete box girders are susceptible to cracking due to excessive temperature differentials induced by early-age hydration heat, compromising structural reliability and durability. Investigating the early-age hydration heat in large precast box girders and proposing corresponding temperature control measures based on influencing factor analysis is therefore essential. The present research employs field testing and numerical simulation of a 60 m precast railway box girder to develop a UMATHT subroutine and establish a refined finite element model incorporating temperature-dependent material properties and hydration degree. Results demonstrate that the early-age temperature field exhibits an initial rise followed by a decline. Pouring temperature exhibits a positive correlation with both peak temperature and maximum temperature differential; a 5 °C increase in pouring temperature elevates the temperature differential by nearly 1.8 °C. Cement content significantly affects peak temperature, with an average increase of approximately 5.4 °C per additional 50 kg/m3 of cement. Ambient wind speed exerts a greater influence on temperature evolution during the cooling phase than the heating phase. Increased ambient wind speed reduces the peak sectional temperature while concurrently increasing the surface temperature gradient on the windward side of the girder.

11 April 2025 in Coatings
Verified
Journal Article
Open access
PDF file
YFYuanji Fan
Yuanji Fan
DXDanyang Xiong
Danyang Xiong
DHDeng Hong
Deng Hong
FWFei Wang
Fei Wang
XFXu Feng
Xu Feng
Q.W. YangQ.W. Yang
Q.W. Yang
To investigate the spatiotemporal distribution of early-age hydration heat-induced temperature fields, this study integrates distributed fiber optic sensing (DFOS) technology with a thermal parameter finite element model (FEM). First, a high-precision DFOS system and traditional point-type semiconductor sensors were deployed to continuously monitor the temperature of a 50 m large-volume concrete box girder (LVBG) over 100 h. Experimental results show that full-field LVBG temperature changes can be measured by DFOS compared to traditional point sensors. DFOS, leveraging its full-scale spatial coverage capability, revealed a three-stage temperature evolution: rapid heating (peak temperature of 79.4 °C at 40 h), sustained high temperatures (>75 °C for 20 h), and gradual cooling (rate: 0.45 °C/h). In contrast, conventional point sensors may miss localized hotspots due to insufficient spatial coverage. Second, a FEM was developed on the ABAQUS 2021 (finite element analysis software) platform, incorporating a UMATHT (user material thermal) subroutine to update temperature-dependent thermal conductivity and specific heat in real time during hydration heat transfer simulations. The proposed model significantly improved prediction accuracy by integrating parameter mechanisms (equivalent age), and it improved prediction accuracy by about 40% compared to static-parameter models. The FEM results exhibited strong consistency with DFOS-measured data, validating the model’s reliability in capturing thermal gradients in geometrically complex structures. This validated framework offers a robust tool for optimizing thermal management strategies in large-scale infrastructure projects. The research results of this paper can serve as a reference for the temperature measurement and prediction of large-volume concrete.