Matteo Ricci

Mr. Matteo Ricci

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 June 2026
Verified
Book Chapter
Closed access
PDF file
MRMatteo Ricci
Matteo Ricci
DSDaniel Suarez
Daniel Suarez
LFLorenzo Facila
Lorenzo Facila
FHFernando Hornero
Fernando Hornero
RMRaul Alcaraz Martinez
Raul Alcaraz Martinez
José J. RietaJosé J. Rieta
José J. Rieta

4 June 2026
Verified
Book Chapter
Closed access
MRMatteo Ricci
Matteo Ricci
DSDaniel Suarez
Daniel Suarez
VBVicente Bertomeu-Gonzalez
Vicente Bertomeu-Gonzalez
AMArturo Martinez-Rodrigo
Arturo Martinez-Rodrigo
RMRaul Alcaraz Martinez
Raul Alcaraz Martinez
José J. RietaJosé J. Rieta
José J. Rieta

20 October 2026 in Sensors
Verified
Journal Article
Open access
PDF file
MRMatteo Ricci
Matteo Ricci
DSDaniel Suarez
Daniel Suarez
VBVicente Bertomeu-Gonzalez
Vicente Bertomeu-Gonzalez
AMArturo Martinez-Rodrigo
Arturo Martinez-Rodrigo
RMRaul Alcaraz Martinez
Raul Alcaraz Martinez
José J. RietaJosé J. Rieta
José J. Rieta
Photoplethysmography (PPG) is widely used in wearable devices, but wrist- and arm-worn recordings are sensitive to motion artifacts, ambient light, and changes in sensor–skin contact. This study presents an adaptive preprocessing pipeline that combines accelerometer-derived motion-state clustering, an ambient-light-based Contact Quality Index (CQI), and cluster-based Symlet 4 wavelet filtering. Motion states are obtained from less posture-dependent features of 10 s accelerometer windows, whereas the CQI is a heuristic indicator of ambient-light-related optical reliability, scaled from 0 to 1, that flags low-reliability segments without changing their motion label. The wavelet stage removes baseline drift, soft-thresholds the high-frequency detail bands with thresholds selected on training data, and preserves the bands that overlap the cardiac frequency range. The model was trained on 8 participants and evaluated on 27 held-out participants against a simultaneously recorded ECG. Compared with a band-pass filter and an accelerometer-referenced adaptive filter, the proposed method detected more beats (median sensitivity 1.00 vs. 0.91 and 0.92) and reduced the inter-beat-interval (IBI) error when missed beats were included (128.0 vs. 181.2 and 156.8 ms), particularly during movement, at the cost of a lower positive predictive value (0.92 vs. 1.00), whereas the reference filters yielded lower IBI error on detected beats (24.6 and 26.6 vs. 38.7 ms). The method also outperformed a fixed Daubechies 4 wavelet filter on all timing metrics. In a band-energy analysis, it reduced out-of-band energy by a median of 27.7 dB but also reduced useful-band energy by 41.0%. These results show that a lightly thresholded wavelet filter recovers more beats than fixed filters during daily-life movement, whereas the benefit of cluster-specific thresholds remains to be established in other cohorts and during higher-intensity activities.