Daniel Suarez

Dr. Daniel Suarez


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2018 in Forensic Science International
Verified
Journal Article
Closed access
LFLucía Fernández-López
Lucía Fernández-López
PSPROYECTOS S.L.
PROYECTOS S.L.
GPGemma Prieto-Bonete
Gemma Prieto-Bonete
CPCristina Pérez-Martínez
Cristina Pérez-Martínez
JNJavier Navarro-Zaragoza
Javier Navarro-Zaragoza
Aurelio LunaAurelio Luna
Aurelio Luna

4 June 2026
Verified
Book Chapter
Closed access
PDF file
MRMatteo Ricci
Matteo Ricci
DSDaniel Suarez
Daniel Suarez
LFLorenzo Facila
Lorenzo Facila
FHFernando Hornero
Fernando Hornero
RMRaul Alcaraz Martinez
Raul Alcaraz Martinez
José J. RietaJosé J. Rieta
José J. Rieta

4 June 2026
Verified
Book Chapter
Closed access
MRMatteo Ricci
Matteo Ricci
DSDaniel Suarez
Daniel Suarez
VBVicente Bertomeu-Gonzalez
Vicente Bertomeu-Gonzalez
AMArturo Martinez-Rodrigo
Arturo Martinez-Rodrigo
RMRaul Alcaraz Martinez
Raul Alcaraz Martinez
José J. RietaJosé J. Rieta
José J. Rieta

31 October 2026 in Sensors
Verified
Journal Article
Open access
PDF file
PCPietro Chierico
Pietro Chierico
DSDaniel Suarez
Daniel Suarez
LFLorenzo Facila
Lorenzo Facila
FHFernando Hornero
Fernando Hornero
RMRaul Alcaraz Martinez
Raul Alcaraz Martinez
José J. RietaJosé J. Rieta
José J. Rieta
Photoplethysmography (PPG) is a widely used, non-invasive technique for heart rate monitoring, but its reliability is often compromised by noise and motion artifacts (MAs). This study presents the Peakwise Correlation Pulse Detector (PCPD), an algorithm for detecting heartbeats directly from PPG signals without requiring electrocardiogram (ECG) signals during operation, evaluated here under clean and controlled synthetic pulse-free-noise conditions. PCPD follows a five-step pipeline: (1) signal segmentation with overlap, (2) sliding cross-correlation using high-quality heartbeat templates, (3) computation of the Minimum Correlation Curve (MCC), (4) feature extraction with machine learning-based classification, and (5) peak translation with constraint analysis. The method was evaluated on a clean dataset, comprising a newly collected PPG dataset with manually annotated signal quality and the publicly available BIDMC dataset, and on a noisy dataset that augments the clean data with synthetic pulse-free segments generated from band-limited Gaussian noise. This evaluation framework tests heartbeat detectors under ideal conditions and under a controlled non-informative-noise protocol. On clean signals, PCPD achieved balanced precision–recall scores of 99.13% on the proposed dataset (internal performance) and 97.04% on the independent BIDMC dataset. Under added synthetic pulse-free noise, PCPD achieved accuracies of 99.30% and 97.16% on the proposed and BIDMC datasets, respectively. In comparative experiments against eleven benchmark heartbeat detection algorithms, PCPD achieved the best performance among the evaluated implementations under the tested synthetic-noise protocol. These results support PCPD as a promising PPG-only peak detector and motivate further validation under real motion artifacts and for downstream signal quality assessment.

14 June 2024 in Journal of Forensic Science and Research
Verified
Journal Article
Open access
PDF file
DSDaniel Suarez
Daniel Suarez
PEPascual E
Pascual E
VRValdes R
Valdes R
DCDiego C
Diego C
MRMunera R
Munera R
Chemical submission is a crime where criminals use substances to impose their will on victims. A 44-year-old woman comes to the Health Center disoriented in the temporal sphere, stating that “she does not remember what happened.” Her brother, the companion who brings her to the health center, says that he has found her in a place he does not usually frequent. The patient missed a bag she was carrying and could not locate her mobile phone. The patient and companion suspect that she may have been “drugged” in order to rob them. Given the suspicion that the patient may have been a victim of chemical submission, the Emergency Service is called to inform that the victim is going to be referred. The detection of biological samples of the substances used for submission is of vital importance.

29 August 2023
Verified
Book Chapter
Closed access
PDF file
MVMaría Beatriz Villar-López
María Beatriz Villar-López
ÁGÁgueda Gómez-Cambronero
Águeda Gómez-Cambronero
DSDaniel Suarez
Daniel Suarez
IRInmaculada Remolar
Inmaculada Remolar