Atousa Parsaei

Ms. Atousa Parsaei

Biomedical Engineering, University of Calgary, Calgary, Alberta, Canada
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 October 2024 in Sensors
Verified
Journal Article
Open access
PDF file
RAReza Ahmadi
Reza Ahmadi
SRShahram Rasoulian
Shahram Rasoulian
SVSamira Fazeli Veisari
Samira Fazeli Veisari
Atousa ParsaeiAtousa Parsaei
Atousa Parsaei
HHHamidreza Heidary
Hamidreza Heidary
Amin KomeiliAmin Komeili
Amin Komeili
Accurate measurement of pedaling kinetics and kinematics is vital for optimizing rehabilitation, exercise training, and understanding musculoskeletal biomechanics. Pedal reaction force, the main external force in cycling, is essential for musculoskeletal modeling and closely correlates with lower-limb muscle activity and joint reaction forces. However, sensor instrumentation like 3-axis pedal force sensors is costly and requires extensive postprocessing. Recent advancements in machine learning (ML), particularly neural network (NN) models, provide promising solutions for kinetic analyses. In this study, an NN model was developed to predict radial and mediolateral forces, providing a low-cost solution to study pedaling biomechanics with stationary cycling ergometers. Fifteen healthy individuals performed a 2 min pedaling task at two different self-selected (58 ± 5 RPM) and higher (72 ± 7 RPM) cadences. Pedal forces were recorded using a 3-axis force system. The dataset included pedal force, crank angle, cadence, power, and participants’ weight and height. The NN model achieved an inter-subject normalized root mean square error (nRMSE) of 0.15 ± 0.02 and 0.26 ± 0.05 for radial and mediolateral forces at high cadence, respectively, and 0.20 ± 0.04 and 0.22 ± 0.04 at self-selected cadence. The NN model’s low computational time suits real-time pedal force predictions, matching the accuracy of previous ML algorithms for estimating ground reaction forces in gait.

30 April 2025 in Computers in Biology and Medicine
Verified
Journal Article
Open access
RKReza Kakavand
Reza Kakavand
RAReza Ahmadi
Reza Ahmadi
Atousa ParsaeiAtousa Parsaei
Atousa Parsaei
WEW. Brent Edwards
W. Brent Edwards
Amin KomeiliAmin Komeili
Amin Komeili
This study evaluates the agreement of marker-based and markerless (OpenCap) motion capture systems in assessing joint kinematics and kinetics during cycling. Markerless systems, such as OpenCap, offer the advantage of capturing natural movements without physical markers, making them more practical for real-world applications. However, the agreement of OpenCap with a marker-based system, particularly in cycling, remains underexplored. Ten participants cycled at varying speeds and resistances while motion data were recorded using both systems. Key metrics, including joint angles, moments, and joint reaction loads, were computed using OpenSim and compared using root mean squared error (RMSE) per trial across participants, Pearson correlation coefficients (r) per trial across participants and repeated measures Bland-Altman to control trials' dependency within subject. Results revealed very strong agreement (r > 0.9) for hip (flexion/extension), knee (flexion/extension), and ankle (dorsiflexion/plantarflexion) joint angles. Relatively high RMSE values of 10.7° (±3.0°) and 12.4° (±4.6°) were observed for left and right ankle dorsiflexion/plantarflexion angles, respectively, per trial across participants. Knee flexion/extension RMSE per trial across participants were 9.3° (±3.8°) and 10.2° (±4.3°) for the left and right limbs, respectively. RMSE values of hip flexion/extension, adduction/abduction and rotation were 7.9° (±2.6°), 3.2° (±1.1°) and 3° (±1.2°) for the left side. Joint reaction forces and moments exhibited moderate to very strong agreement across most degrees of freedom. The RMSE of joint reaction forces ranged from 13.7 to 37.7 %BW. The hip medial-lateral moment had a minimum RMSE of 0.19 %BW × ht, while the highest RMSE of 1.27 %BW × ht was in the knee anterior-posterior moment. Despite strong overall agreement between the systems, variability per trial across participants in RMSE suggested that OpenCap may require further refinement in specific areas. These findings highlight the potential of markerless motion capture systems, such as OpenCap, in biomechanical analyses of cycling while also identifying areas where further refinement may be needed.

3 January 2026 in Sensors
Verified
Journal Article
Open access
PDF file
SSSierra Sweeney
Sierra Sweeney
SRShahram Rasoulian
Shahram Rasoulian
Atousa ParsaeiAtousa Parsaei
Atousa Parsaei
HHHamidreza Heidary
Hamidreza Heidary
RAReza Ahmadi
Reza Ahmadi
Amin KomeiliAmin Komeili
Amin Komeili
Cycling-based rehabilitation is a non-invasive intervention for individuals with lower limb asymmetries. However, current cycling devices lack comprehensive biomechanical feedback and cannot assess asymmetry. Our lab has developed a novel cycle ergometer equipped with three-dimensional force pedals, a seat post and handlebar force sensors, which allow for a comprehensive analysis of asymmetry across a fatiguing task. This study assessed the reproducibility of the cycling kinetics and asymmetry index derived from this device during incremental and constant load cycling tasks to volitional failure. Eighteen participants completed incremental and constant-load tests, each across two identical sessions. Pedal forces and power were analyzed for each leg individually, and handlebar forces and seat post mediolateral sway were recorded during cycling. Normalized symmetry index (NSI), a metric quantifying the degree of asymmetry between limbs, was calculated for each variable. The reproducibility of the device was assessed using repeated measures analysis of variance and intraclass correlation coefficients (ICC). No significant session or interaction effects were found for pedal, handlebar, and seat post measures (all p > 0.05). Time effects were observed for pedal force and power in the incremental test (all p < 0.001). NSI values were reproducible with high ICC values (≥0.70) for force and power. The results suggest that this ergometer offers reproducible cycling kinetics and asymmetry measures across a fatiguing task. The findings support the application of this ergometer in research and rehabilitation settings.

7 August 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
RAReza Ahmadi
Reza Ahmadi
SRShahram Rasoulian
Shahram Rasoulian
SVSamira Fazeli Veisari
Samira Fazeli Veisari
Atousa ParsaeiAtousa Parsaei
Atousa Parsaei
HHHamidreza Heidary
Hamidreza Heidary
Amin KomeiliAmin Komeili
Amin Komeili
Accurate measurement of pedaling kinetics and kinematics is vital for optimizing rehabilitation, exercise training, and understanding musculoskeletal biomechanics. Pedal reaction force, the main external force in cycling, is essential for musculoskeletal modeling and closely correlates with lower limb muscle activity and joint reaction forces. However, sensor instrumentation like 3-axis pedal force sensors is costly and requires extensive post-processing. Recent advancements in machine learning (ML), particularly neural network (NN) models, provide promising solutions for kinetic analyses. In this study, an NN model was developed to predict radial and mediolateral forces, providing a low-cost solution to study pedaling biomechanics with stationary cycling ergometers. Fifteen healthy individuals performed a 2-minute pedaling task at two different self-selected (58±5 rpm) and higher (72±7 rpm) cadences. Pedal forces were recorded using a 3-axis force system. The dataset included pedal force, crank angle, cadence, power, and participants' weight and height. The NN model achieved an inter-subject normalized root mean square error (nRMSE) of 0.15±0.02 and 0.26±0.05 for radial and mediolateral forces at high cadence, respectively, and 0.20±0.04 and 0.22±0.04 at self-selected cadence. The NN model's low computational time suits real-time pedal force predictions, matching the accuracy of previous ML algorithms for estimating ground reaction forces in gait.