Samira Fazeli Veisari

Dr. Samira Fazeli Veisari

Department of Biomedical Engineering, University of Calgary, Calgary, Alberta, Canada

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 June 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
SVSamira Fazeli Veisari
Samira Fazeli Veisari
SBShahrbanoo Bidari
Shahrbanoo Bidari
KBKourosh Barati
Kourosh Barati
RARasha Atlasi
Rasha Atlasi
Amin KomeiliAmin Komeili
Amin Komeili
Scoliosis is one of the most common spinal deformities, which affects millions of people worldwide. Bracing and physiotherapy exercises represent the first-line, non-invasive approaches for managing scoliosis. In recent years, the use of wearable devices has spread as a novel approach to the treatment of scoliosis. However, their effectiveness in treatment planning and outcomes has not been thoroughly evaluated. This manuscript provides a scoping review of the classification and application of wearable devices and the role of artificial intelligence (AI) in interpreting the data collected by wearable devices and guiding the treatment. A systematic search was carried out on Scopus, Web of Science, PubMed, and EMBASE for studies published between January 2020 and February 2025. A total of 269 studies were screened, and 88 articles were reviewed in depth. Inclusion criteria encompassed articles focusing on wearable devices integrated into smart braces, rehabilitation systems for scoliosis management, AI and machine-learning (ML) applications in scoliosis treatment, virtual reality (VR), and telemedicine for scoliosis care. The literature shows that the use of wearable devices can enhance scoliosis treatment by improving the efficiency of braces and enabling remote monitoring in rehabilitation programs. However, more research is needed to evaluate user compliance, long-term effectiveness, and the need for personalized interventions. Future advancements in artificial intelligence, microsensor technology, and data analytics may enhance the efficacy of these devices, which can lead to more personalized and accessible scoliosis treatment.

4 October 2024 in Sensors
Verified
Journal Article
Open access
PDF file
RAReza Ahmadi
Reza Ahmadi
SRShahram Rasoulian
Shahram Rasoulian
SVSamira Fazeli Veisari
Samira Fazeli Veisari
Atousa ParsaeiAtousa Parsaei
Atousa Parsaei
HHHamidreza Heidary
Hamidreza Heidary
Amin KomeiliAmin Komeili
Amin Komeili
Accurate measurement of pedaling kinetics and kinematics is vital for optimizing rehabilitation, exercise training, and understanding musculoskeletal biomechanics. Pedal reaction force, the main external force in cycling, is essential for musculoskeletal modeling and closely correlates with lower-limb muscle activity and joint reaction forces. However, sensor instrumentation like 3-axis pedal force sensors is costly and requires extensive postprocessing. Recent advancements in machine learning (ML), particularly neural network (NN) models, provide promising solutions for kinetic analyses. In this study, an NN model was developed to predict radial and mediolateral forces, providing a low-cost solution to study pedaling biomechanics with stationary cycling ergometers. Fifteen healthy individuals performed a 2 min pedaling task at two different self-selected (58 ± 5 RPM) and higher (72 ± 7 RPM) cadences. Pedal forces were recorded using a 3-axis force system. The dataset included pedal force, crank angle, cadence, power, and participants’ weight and height. The NN model achieved an inter-subject normalized root mean square error (nRMSE) of 0.15 ± 0.02 and 0.26 ± 0.05 for radial and mediolateral forces at high cadence, respectively, and 0.20 ± 0.04 and 0.22 ± 0.04 at self-selected cadence. The NN model’s low computational time suits real-time pedal force predictions, matching the accuracy of previous ML algorithms for estimating ground reaction forces in gait.

3 January 2026 in Sensors
Verified
Journal Article
Open access
PDF file
SSSierra Sweeney
Sierra Sweeney
SRShahram Rasoulian
Shahram Rasoulian
Atousa ParsaeiAtousa Parsaei
Atousa Parsaei
HHHamidreza Heidary
Hamidreza Heidary
RAReza Ahmadi
Reza Ahmadi
Amin KomeiliAmin Komeili
Amin Komeili
Cycling-based rehabilitation is a non-invasive intervention for individuals with lower limb asymmetries. However, current cycling devices lack comprehensive biomechanical feedback and cannot assess asymmetry. Our lab has developed a novel cycle ergometer equipped with three-dimensional force pedals, a seat post and handlebar force sensors, which allow for a comprehensive analysis of asymmetry across a fatiguing task. This study assessed the reproducibility of the cycling kinetics and asymmetry index derived from this device during incremental and constant load cycling tasks to volitional failure. Eighteen participants completed incremental and constant-load tests, each across two identical sessions. Pedal forces and power were analyzed for each leg individually, and handlebar forces and seat post mediolateral sway were recorded during cycling. Normalized symmetry index (NSI), a metric quantifying the degree of asymmetry between limbs, was calculated for each variable. The reproducibility of the device was assessed using repeated measures analysis of variance and intraclass correlation coefficients (ICC). No significant session or interaction effects were found for pedal, handlebar, and seat post measures (all p > 0.05). Time effects were observed for pedal force and power in the incremental test (all p < 0.001). NSI values were reproducible with high ICC values (≥0.70) for force and power. The results suggest that this ergometer offers reproducible cycling kinetics and asymmetry measures across a fatiguing task. The findings support the application of this ergometer in research and rehabilitation settings.

7 August 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
RAReza Ahmadi
Reza Ahmadi
SRShahram Rasoulian
Shahram Rasoulian
SVSamira Fazeli Veisari
Samira Fazeli Veisari
Atousa ParsaeiAtousa Parsaei
Atousa Parsaei
HHHamidreza Heidary
Hamidreza Heidary
Amin KomeiliAmin Komeili
Amin Komeili
Accurate measurement of pedaling kinetics and kinematics is vital for optimizing rehabilitation, exercise training, and understanding musculoskeletal biomechanics. Pedal reaction force, the main external force in cycling, is essential for musculoskeletal modeling and closely correlates with lower limb muscle activity and joint reaction forces. However, sensor instrumentation like 3-axis pedal force sensors is costly and requires extensive post-processing. Recent advancements in machine learning (ML), particularly neural network (NN) models, provide promising solutions for kinetic analyses. In this study, an NN model was developed to predict radial and mediolateral forces, providing a low-cost solution to study pedaling biomechanics with stationary cycling ergometers. Fifteen healthy individuals performed a 2-minute pedaling task at two different self-selected (58±5 rpm) and higher (72±7 rpm) cadences. Pedal forces were recorded using a 3-axis force system. The dataset included pedal force, crank angle, cadence, power, and participants' weight and height. The NN model achieved an inter-subject normalized root mean square error (nRMSE) of 0.15±0.02 and 0.26±0.05 for radial and mediolateral forces at high cadence, respectively, and 0.20±0.04 and 0.22±0.04 at self-selected cadence. The NN model's low computational time suits real-time pedal force predictions, matching the accuracy of previous ML algorithms for estimating ground reaction forces in gait.

15 January 2026 in Sensors
Verified
Journal Article
Open access
PDF file
HHHamidreza Heidary
Hamidreza Heidary
RAReza Ahmadi
Reza Ahmadi
SRShahram Rasoulian
Shahram Rasoulian
SVSamira Fazeli Veisari
Samira Fazeli Veisari
DADavid Auslander
David Auslander
Amin KomeiliAmin Komeili
Amin Komeili
Asymmetry, defined as unequal neuromuscular activation or mechanical performance between contralateral limbs, plays a critical role in cycling efficiency and injury risk. While kinematic and kinetic measures are commonly used to assess asymmetry, surface electromyography (EMG) signals offer an additional perspective on neuromuscular asymmetry. This study evaluated muscle activation asymmetry during cycling using the Normalized Symmetry Index (NSI), a metric that quantifies differences in kinematics and kinetics between limbs, where higher values indicate greater asymmetry. NSI was calculated from EMG recordings of seven lower-limb muscles under two test conditions: step incremental and constant-power cycling to task failure. Twenty recreationally active participants performed both tests on a stationary ergometer while EMG data were collected bilaterally. Step incremental cycling resulted in a significant reduction in NSI for key muscles in the quadriceps group: vastus medialis (from 44% to 21%, p < 0.001), vastus lateralis (from 45% to 22%, p = 0.002), rectus femoris (from 54% to 24%, p < 0.001), and biceps femoris (from 52% to 29%, p = 0.003). No significant changes were observed for the tibialis anterior, soleus, or gastrocnemius medialis. In contrast, under constant-power conditions, NSI values remained unchanged over time for all muscles (all p > 0.05), with average NSI values ranging from 12% to 30%, indicating consistent bilateral activation. These findings highlight the sensitivity of surface EMG in detecting workload-dependent changes in muscle activation asymmetry and suggest that higher cycling intensities, compared to lower ones, may promote more balanced engagement of primary cycling muscles.