Gabriele Fassina

Mr. Gabriele Fassina

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2025 in Journal of Experimental Orthopaedics
Verified
Journal Article
Open access
TBTommaso Bonanzinga
Tommaso Bonanzinga
AFALBERTO FAVARO
ALBERTO FAVARO
LBLuca Bertolino
Luca Bertolino
GFGabriele Fassina
Gabriele Fassina
BSBharat Sharma
Bharat Sharma
FIFrancesco Iacono
Francesco Iacono
Purpose: To investigate whether a novel femoral component with a trochlear sulcus externally rotated (EXT) by 3°, mimicking the natural relationship between the posterior condylar axis (PCA) and epicondylar axis (EA), improves patellofemoral (PF) kinematics in total knee arthroplasty (TKA) by more closely replicating native patellar motion. Methods: A cadaveric study was conducted on 12 lower limbs from six fresh‐frozen hemi‐body specimens. After acquiring native knee kinematics using an optical navigation system, each knee underwent TKA with two prosthetic designs: a standard (STD) implant and an EXT variant with a 3° lateralized trochlear groove. Patellar kinematics were evaluated in flexion–extension movements, and quantified via root mean square error, correlation coefficient and normalized range relative to native conditions. Statistical comparisons were performed using the Wilcoxon signed‐rank test. Results: Patellar flexion was similar across native and prosthetic conditions. However, the STD design showed significantly lower patellar misalignment than the EXT in terms of patellar shift ( p < 0.01) and exhibited lower inter‐specimen variability. The EXT design resulted in an inversion of patellar tilt patterns and demonstrated reduced correlation with native tilt kinematics. In terms of internal patellar rotation, patterns post‐implantation were comparable between the STD and EXT designs, emerging beyond 50° of flexion. The expected benefits of trochlear external rotation were not confirmed. Conclusions: Although theoretically promising, the EXT trochlear design did not lead to improved replication of native PF kinematics. The findings suggest that trochlear sulcus lateralization alone is insufficient to restore physiological patellar tracking. Level of Evidence: Level V, cadaveric study.

27 June 2026 in Sensors
Verified
Journal Article
Open access
PDF file
GFGabriele Fassina
Gabriele Fassina
Serena CerfoglioSerena Cerfoglio
Serena Cerfoglio
MRMichele Rigucci
Michele Rigucci
Alessandra PedrocchiAlessandra Pedrocchi
Alessandra Pedrocchi
Veronica CimolinVeronica Cimolin
Veronica Cimolin
EAEmilia Ambrosini
Emilia Ambrosini
Assessment of upper-limb kinematics is essential in clinical practice for diagnosis, rehabilitation monitoring, and treatment personalization. Markerless Motion Capture (MMC) systems, such as the Microsoft Azure Kinect (AK), offer a low-cost and time-efficient alternative to marker-based systems. However, while AK accuracy has been extensively studied for lower-limb movements, its performance for upper-limb analysis—especially under clinically relevant, suboptimal conditions—remains underexplored. This study aims to validate AK for upper-limb motion tracking against a gold-standard optoelectronic system under optimal and suboptimal conditions. Sixteen healthy adults performed ten upper body motor tasks in three scenarios: optimal setup, seated posture with table occlusion, and increased camera distance. Joint angles were compared using normalized Root Mean Squared Error (nRMSE) and Pearson’s correlation coefficient. Performance Indicators (PIs) including Range of Motion (ROM), smoothness, and Time to Peak Velocity (TTPV) were also evaluated. AK accurately captured movements performed within the camera plane, with median nRMSE below 20% in optimal conditions and no significant degradation in suboptimal setups. In contrast, movements occurring on planes perpendicular to the camera were poorly captured. ROM estimation was acceptable and highly reproducible, while TTPV showed moderate-to-poor reliability and smoothness deviated substantially from the reference system. These findings suggest that careful attention to Kinect positioning is essential to ensure effective acquisitions, even in suboptimal scenarios. Future research should evaluate AK validity in clinical populations and explore the effects of system interference in multi-device setups.