Ana Martina Botti

Dr. Ana Martina Botti

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
DRDario Rodrigues
Dario Rodrigues
KAKevin Andersson
Kevin Andersson
MCMariano Cababie
Mariano Cababie
ADAndre Donadon
Andre Donadon
ABAna Martina Botti
Ana Martina Botti
SUSho Uemura
Sho Uemura

10 June 2021 in Physical Review Applied
Verified
Journal Article
Closed access
PDF file
GMGuillermo Fernandez Moroni
Guillermo Fernandez Moroni
KAKevin Andersson
Kevin Andersson
ABAna Martina Botti
Ana Martina Botti
JEJuan Estrada
Juan Estrada
DRDario Rodrigues
Dario Rodrigues
JTJavier Tiffenberg
Javier Tiffenberg
Low-noise fully depleted charge-coupled devices have been identified as a unique tool for dark-matter searches, low-energy neutrino physics, and x-ray detection. The charge-collection efficiency (CCE) for these detectors is a critical performance parameter for current and future experiments. We present a technique to characterize the CCE in back-illuminated CCDs based on soft x rays. This technique is used to study two different detector designs. The results demonstrate the importance of the backside processing for the detection of charge packages near threshold, showing that a recombination layer of a few microns significantly distorts the low-energy spectrum. The studies demonstrate that the region of partial charge collection can be reduced to a thickness of less than 1μm with adequate backside processing.

25 April 2025 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
SCSENSEI Collaboration
SENSEI Collaboration
IBItay M. Bloch
Itay M. Bloch
ABAna Martina Botti
Ana Martina Botti
MCMariano Cababie
Mariano Cababie
GCGustavo Cancelo
Gustavo Cancelo
TYTien-Tien Yu
Tien-Tien Yu
We present results from data acquired by the SENSEI experiment at SNOLAB after a major upgrade in May 2023, which includes deploying 16 new sensors and replacing the copper trays that house the CCDs with a new light-tight design. We observe a single-electron event rate of $(1.39\ifmmode\pm\else\textpm\fi{}0.11)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}5}\text{ }\text{ }{\mathrm{e}}^{\ensuremath{-}}/\mathrm{pix}/\mathrm{day}$, corresponding to $(39.8\ifmmode\pm\else\textpm\fi{}3.1)\text{ }\text{ }{\mathrm{e}}^{\ensuremath{-}}/\mathrm{gram}/\mathrm{day}$. This is an order-of-magnitude improvement compared to the previous lowest single-electron rate in a silicon detector and the lowest for any photon detector in the wavelength range between near-infrared and ultraviolet. We use these data to obtain a 90% confidence level upper bound of $1.53\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}5}\text{ }\text{ }{\mathrm{e}}^{\ensuremath{-}}/\mathrm{pix}/\mathrm{day}$ and to set constraints on sub-GeV dark matter candidates that produce single-electron events. We hypothesize that the data taken at SNOLAB in the previous run, with an older tray design for the sensors, contained a larger rate of single-electron events due to light leaks. We test this hypothesis using data from the SENSEI detector located in the MINOS cavern at Fermilab.

17 October 2022 in Physical Review D
Verified
Journal Article
Closed access
PDF file
ABAna Martina Botti
Ana Martina Botti
SUS. Uemura
S. Uemura
GMG. Fernandez Moroni
G. Fernandez Moroni
LBL. Barak
L. Barak
MCM. Cababie
M. Cababie
TVT. Volansky
T. Volansky
Fully depleted thick silicon skipper-charge-coupled devices (skipper CCDs) are an important technology to probe neutrino and light-dark-matter interactions due to their subelectron read-out noise. However, the successful search for rare neutrino or dark-matter events requires the signal and all backgrounds to be fully characterized. In particular, a measurement of the electron-hole pair creation energy below 150 eV and the Fano factor are necessary for characterizing the dark matter and neutrino signals. Moreover, photons from background radiation may Compton scatter in the silicon bulk, producing events that can mimic a dark matter or neutrino signal. We present a measurement of the Compton spectrum using a skipper CCD and a Am241 source. With these data, we estimate the electron-hole pair-creation energy to be (3.71±0.08)  eV at 130 K in the energy range between 99.3 eV and 150 eV. By measuring the widths of the steps at 99.3 eV and 150 eV in the Compton spectrum, we introduce a novel technique to measure the Fano factor, setting an upper limit of 0.31 at 90% C.L. These results prove the potential of skipper CCDs to characterize the Compton spectrum and to measure precisely the Fano factor and electron-hole pair creation energy below 150 eV.

1 September 2024 in Publications of the Astronomical Society of the Pacific
Verified
Journal Article
Closed access
KLKenneth W. Lin
Kenneth W. Lin
AKArmin Karcher
Armin Karcher
JGJulien Guy
Julien Guy
SHStephen E. Holland
Stephen E. Holland
WKWilliam F. Kolbe
William F. Kolbe
JTJavier Tiffenberg
Javier Tiffenberg
We present characterization results and performance of a prototype Multiple-Amplifier Sensing (MAS) silicon charge-coupled device (CCD) sensor with 16 channels potentially suitable for faint object astronomical spectroscopy and low-signal, photon-limited imaging. The MAS CCD is designed to reach sub-electron readout noise by repeatedly measuring charge through a line of amplifiers during the serial transfer shifts. Using synchronized readout electronics based on the Dark Energy Spectroscopic Instrument CCD controller, we report a read noise of 1.03 e− rms pix−1 at a speed of 26 μs pix−1 with a single-sample readout scheme where charge in a pixel is measured only once for each output stage. At these operating parameters, we find the amplifier-to-amplifier charge transfer efficiency (ACTE) to be >0.9995 at low counts for all amplifiers but one for which the ACTE is 0.997. This charge transfer efficiency falls above 50,000 electrons for the read-noise optimized voltage configuration we chose for the serial clocks and gates. The amplifier linearity across a broad dynamic range from ∼300 to 35,000 e− was also measured to be ±2.5%. We describe key operating parameters to optimize on these characteristics and describe the specific applications for which the MAS CCD may be a suitable detector candidate.

31 October 2024 in Journal of Astronomical Telescopes, Instruments, and Systems
Verified
Journal Article
Closed access
PDF file
ALAgustín J. Lapi
Agustín J. Lapi
BGBlas J. Irigoyen Gimenez
Blas J. Irigoyen Gimenez
MGMiqueas E. Gamero
Miqueas E. Gamero
CCClaudio Rodrigo Chavez
Claudio Rodrigo Chavez
FCFernando Chierchie
Fernando Chierchie
JEJuan Estrada
Juan Estrada
We present a candidate sensor for future spectroscopic applications, such as a Stage-5 Spectroscopic Survey Experiment or the Habitable Worlds Observatory. This type of charge-coupled device (CCD) sensor features multiple in-line amplifiers at its output stage allowing multiple measurements of the same charge packet, either in each amplifier or in the different amplifiers. Recently, the operation of an eight-amplifier sensor has been experimentally demonstrated, and we present the operation of a 16-amplifier sensor. This new sensor enables a noise level of ∼1 erms− with a single sample per amplifier. In addition, it is shown that sub-electron noise can be achieved using multiple samples per amplifier. In addition to demonstrating the performance of the 16-amplifier sensor, we aim to create a framework for future analysis and performance optimization of this type of detectors. New models and techniques are presented to characterize specific parameters, which are absent in conventional CCDs and Skipper CCDs: charge transfer between amplifiers and independent and common noise in the amplifiers and their processing.