Knowledge of the sound velocity of core materials is essential to explain the observed anomalously low shear wave velocity (VS) and high Poisson’s ratio (σ) in the solid inner core. To date, neitherVSnorσof Fe and Fe-Si alloy have been measured under core conditions. Here, we presentVSandσderived from direct measurements of the compressional wave velocity, bulk sound velocity, and density of Fe and Fe-8.6 wt%Si up to ~230 GPa and ~5400 K. The new data show that neither the effect of temperature nor incorporation of Si would be sufficient to explain the observed lowVSand highσof the inner core. A possible solution would add carbon (C) into the solid inner core that could further decreaseVSand increaseσ. However, the physical property-based Fe-Si-C core models seemingly conflict with the partitioning behavior of Si and C between liquid and solid Fe.
Cubic solids such as NaCl, crystalline argon, or H2O-ice VII exhibit significant elastic anisotropy strongly increasing upon compression. As earlier recognized for solid argon and H2O-ice (both exhibiting Zener ratio A > 1), longitudinal sound velocities of their polycrystals, VLav, measured using Brillouin light scattering (BLS) or pulse-echo ultrasonics are much closer to VL⟨111⟩ than to VL⟨100⟩, the VL-extremes in any cubic single crystal. Here, we experimentally confirm, using the technique of time-domain Brillouin scattering, the same tendency for NaCl exhibiting the opposite anisotropy type, A < 1. To understand this tendency, we modelled orientational distribution and the frequency of occurrence of VL values in texture-free polycrystalline samples of NaCl and solid argon. We found a remarkable and predictable asymmetry of VL distributions with maxima at VL⟨110⟩ that is always much closer to VL⟨111⟩. This asymmetry persists in BLS peaks but can be obscured in experiments. In the case of solid argon at 49 GPa, the asymmetry can lead to a moderate deviation of experimental VLav from VLH (obtained from elastic-stiffness constants Cij applying the Hill approximation) by ∼7%. The latter can cause, however, a significant overestimation of the aggregate shear modulus by δG/G ∼ 50% or of the bulk modulus by δB/B ∼ 20% if just one BLS peak of longitudinal modes is detectable. A similar analysis, performed for transverse sound velocities, VT and VTav, has shown that by the use of a BLS spectrum showing peaks of both longitudinal and transverse modes, overestimation of B is similarly high but that of G is much less dramatic.
Pressure dependences of the highest and lowest possible longitudinal sound velocities in single crystals of the B1 and B2 phases of NaCl were extracted from examination of their polycrystalline samples using the technique of time-domain Brillouin scattering. Based on the data collected up to 41 GPa, we largely extended the pressure range where single-crystal elastic moduli, Cij(P), and elastic anisotropy of the two cubic phases are measured, especially the experimental data for the B2 phase formed upon the reconstructive phase transition. The B1 phase of NaCl exhibits strong and growing anisotropy with increasing pressure, while that of the B2 phase is much weaker. Comparing with the previous experimental Cij(P) of other compounds exhibiting or expected to exhibit the B1–B2 phase transition, such as CaO, MgO, and (Mg1−x, Fex)O, we concluded that the transition is initiated by the shear instability due to violation of the Born stability criterion [C44(P)–P] > 0 and predicted the presently-not-verified transition pressures for MgO and (Mg1−x, Fex)O.
In this paper, a novel topology and method for designing a multi-band rectenna is proposed to improve its RF-DC efficiency. The rectifier achieves simultaneous rectification using both series and parallel configurations by connecting two branches to the respective terminals of the diode, directing the energy input from two ports to the anode and cathode of the diode. Six desired operating frequency bands are evenly distributed across these two branches, each of which is connected to antennas corresponding to their specific operating frequencies, serving as the receiving end of the system. To optimize the design process, a low-pass filter is incorporated into the rectifier design. This filter works in conjunction with a matching network that includes filtering capabilities to isolate the two ports of the rectifier. The addition of the filter ensures that each structure within the rectifier can be designed independently without adversely affecting the performance of the already completed structures. Based on the proposed design methodology, a dual-port rectenna operating at six frequency bands—1.85 GHz, 2.25 GHz, 2.6 GHz, 3.52 GHz, 5.01 GHz, and 5.89 GHz—was designed, covering the 4G, 5G, and Wi-Fi/WLAN frequency bands. The measured results indicate that high-power conversion efficiency was achieved at an input power of −10 dBm: 43.01% @ 1.85 GHz, 41.00% @ 2.25 GHz, 41.33% @ 2.6 GHz, 35.88% @ 3.52 GHz, 22.36% @ 5.01 GHz, and 19.27% @ 5.89 GHz. When the input power is −20 dBm, the conversion efficiency of the rectenna can be improved from 5.2% for single-tone input to 27.7% for six-tone input, representing a 22.5 percentage point improvement. The proposed rectenna demonstrates significant potential for applications in powering low-power sensors and other devices within the Internet of Everything context.