Selective catalytic reduction (SCR) is now an established NOxremoval technology for industrial flue gas as well as for diesel engine exhaust gas. However, it is still a big challenge to develop a novel low-temperature catalyst for NH3-SCR of NOx, especially at a temperature below 200°C. In the past few years, many studies have demonstrated the potential of iron (Fe)-based catalysts as low-temperature catalysts for NH3-SCR of NOx. Herein, we summarize the recent progress and performance of Fe-based catalysts for low-temperature NH3-SCR of NOx. Catalysts are divided into three categories: single FexOy, Fe-based multimetal oxide, and Fe-based multimetal oxide with support catalysts. The catalytic activity and selectivity of Fe-based catalysts are systematically analyzed and summarized in light of some key factors such as activation energy, specific surface area, morphology, crystallinity, preparation method and precursor, acid sites, calcination temperature, other metal dopant/substitute, and redox property of catalysts. In addition, H2O/SO2tolerance and the NH3-SCR reaction mechanism over Fe-based catalysts, including Eley-Rideal and Langmuir-Hinshelwood mechanism, are emphasized. Lastly, the perspectives and future research directions of low-temperature NH3-SCR of NOxare also proposed.
18 June 2019 in Journal of Materials Engineering and Performance
Due to its good corrosion resistance and high rigidity, fluoroplastic steel heat exchangers have become one of the main feasible solutions to the problem of flue gas waste heat recovery. Therefore, a heat transfer performance test of a fluoroplastic steel heat exchanger was carried out, and a new heat transfer correlation (Nu = 0.11Re0.72Pr0.36, 1900 < Re < 4100, Pr ≈ 0.8) of a fluid transverse tube bank suitable for smooth fluoroplastic surfaces was proposed. Comparing the results of the proposed correlation and the Zhukauskas correlation, the calculation discrepancy was decreased when using the proposed correlation, and the average discrepancy dropped from 16.8% to 3.3%. As the thickness of the fluoroplastic film was reduced, the gap between the two correlations widened. Thus, the Zhukauskas correlation was not applicable to fluoroplastic steel heat exchangers with a thin fluoroplastic film. However, the deviation between the two correlations decreased as the condensing heat transfer area increased. For the fluoroplastic steel heat exchanger with a large condensation heat transfer area, the Zhukauskas correlation could still be utilized. It was interesting to observe that the deviation between the two correlations was reduced when only flue gas condensation was present, but it showed an increasing trend with the increase in condensation intensity.
The quality of the data determines the quality of the model. In this paper, the grassland degradation data in the Headwaters of the Three Rivers were processed in the early stage and labeled with multiple classification. Guided clustering and semi-supervised clustering were used for comparison. The two methods were combined to classify and label the data, so as to improve the accuracy and completeness of the classification data.