Ana Macarro Merino

Dr. Ana Macarro Merino


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 March 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
José Ignacio Fernández-VigoJosé Ignacio Fernández-Vigo
José Ignacio Fernández-Vigo
Bárbara Burgos-BlascoBárbara Burgos-Blasco
Bárbara Burgos-Blasco
LDLucía De-Pablo-Gómez-De-Liaño
Lucía De-Pablo-Gómez-De-Liaño
IGInes Sanchez Guillen
Ines Sanchez Guillen
VAVirginia Albitre-Barca
Virginia Albitre-Barca
AMAna Macarro Merino
Ana Macarro Merino
Purpose: To propose a classification of the glistening in intraocular lenses (IOL) using swept-source optical coherence tomography (SS-OCT) by means of a simple, objective and reproducible method that allows the quantification of the presence and severity of glistening. Methods: A cross-sectional study on a sample of 150 eyes of 150 patients who underwent cataract surgery in at least 600 days before the exam and attended a routine examination. Each subject was examined by SS-OCT after pupil dilation, identifying the presence of glistening or hyperreflective foci (HRF) in the central area of the IOL. The degree of glistening was classified into four categories: 0: ≤5 HRF; 1: 6 to 15 HRF; 2: 16 to 30 HRF; and 3: >30 HRF. The intra and interobserver reproducibility (intraclass correlation coefficient, ICC) in the quantification and classification of the glistening were calculated. The correlation between the horizontal and vertical scan of the IOL was also assessed. Results: Glistening was present in the IOL in 42.7% of the patients. The mean number of HRF or glistening microvacuoles was 10.4 ± 26.2 (range 0 to 239). In total, 63.3% of the IOLs had a grade 0, 20% grade a 1, 6.7% grade a 2 and 10% a grade 3. The intraobserver and interobserver reproducibility were very high, both for the absolute quantification of the glistening (ICC ≥ 0.994) and for the severity scale (ICC ≥ 0.967). There was an excellent correlation in the quantification of the IOL glistening between the horizontal and vertical scans (R ≥ 0.834; p < 0.001). Conclusions: The use of SS-OCT makes it possible to identify, quantify and classify IOL glistening in a simple, objective and reproducible way. This technique could provide relevant information for the study of the glistening on IOLs.

19 September 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
José Ignacio Fernández-VigoJosé Ignacio Fernández-Vigo
José Ignacio Fernández-Vigo
Bárbara Burgos-BlascoBárbara Burgos-Blasco
Bárbara Burgos-Blasco
LDLucía De-Pablo-Gómez-De-Liaño
Lucía De-Pablo-Gómez-De-Liaño
IAIgnacio Almorín-Fernández-Vigo
Ignacio Almorín-Fernández-Vigo
PVPedro Arriola Villalobos
Pedro Arriola Villalobos
José Ignacio Fernández-VigoJosé Ignacio Fernández-Vigo
José Ignacio Fernández-Vigo
Anterior segment optical coherence tomography (AS-OCT) has emerged as a crucial imaging technique in ophthalmology, particularly for evaluating intraocular structures and the behavior of phakic and secondary intraocular lenses (IOLs). This narrative review summarizes the latest findings and clinical applications of OCT regarding phakic and secondary IOLs, focusing on their effectiveness, safety, and factors influencing performance. Through a comprehensive analysis of current literature, we explore how OCT facilitates the assessment of IOLs on key anatomical parameters—such as vault, angle configuration, lens centration, tilt, and haptic positioning—essential for optimizing surgical outcomes and minimizing postoperative complications. In phakic IOLs, including posterior chamber lenses such as the Implantable Collamer Lens (ICL, STAAR Surgical, Monrovia, CA, USA) and iris-fixated lenses, such as Artiflex (Ophtec BV, Groningen, The Netherlands), OCT enables precise evaluation of the anterior segment, aiding both candidate selection and long-term monitoring. In secondary implants for aphakia—especially iris-fixated lenses like Artisan (Ophtec BV, Groningen, The Netherlands) and sutureless scleral-fixated lenses such as the Carlevale IOL (Soleko, Rome, Italy)—or those implanted via the Yamane technique, OCT provides high-resolution visualization of haptic fixation, IOL stability, and potential complications, including tilt or decentration. This review also highlights comparative insights between fixation techniques, underscores the need for standardized OCT protocols, and discusses the integration of artificial intelligence tools. In summary, the routine use of OCT in the preoperative and postoperative management of phakic and secondary IOLs has been increasingly incorporated into clinical practice, as it enhances clinical decision-making and improves patient outcomes.

Verified
Journal Article
Open access
PDF file
IAIgnacio Almorín-Fernández-Vigo
Ignacio Almorín-Fernández-Vigo
ISInés Sánchez-Guillén
Inés Sánchez-Guillén
José Ignacio Fernández-VigoJosé Ignacio Fernández-Vigo
José Ignacio Fernández-Vigo
Bárbara Burgos-BlascoBárbara Burgos-Blasco
Bárbara Burgos-Blasco
LDLucía De-Pablo-Gómez-De-Liaño
Lucía De-Pablo-Gómez-De-Liaño
AMAna Macarro Merino
Ana Macarro Merino
Corneal astigmatism correction is a key factor when planning refractive treatment for ametropies with intraocular lenses. We aim to obtain normative anterior and posterior corneal astigmatism (ACA and PCA, respectively) data in a local population and to describe their axis distribution and their association with other parameters. A total of 795 patients with no ocular diseases were evaluated with corneal tomography and optical biometry. Only data of the right eye were included. Mean ACA and PCA were 1.01 ± 0.79 and 0.34 ± 0.17 D, respectively. Vertical steep axis distribution was 73.5% for ACA and 93.3% for PCA. Axis orientation between ACA and PCA matched best for vertical orientation (especially 90° to 120°). Vertical ACA orientation frequency decreased with age, with a more positive sphere and less ACA. Vertical PCA orientation frequency increased with higher PCA. Eyes with vertical ACA orientation were younger and showed a greater white-to-white (WTW) measurement, anterior corneal elevations, ACA and PCA. Eyes with vertical PCA orientation were younger and showed greater anterior corneal elevations and PCA. Normative ACA and PCA data in a Spanish population were presented. Steep axis orientations presented differences with age, WTW, anterior corneal elevations and astigmatism.

22 November 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
José Ignacio Fernández-VigoJosé Ignacio Fernández-Vigo
José Ignacio Fernández-Vigo
LDLucía De-Pablo-Gómez-De-Liaño
Lucía De-Pablo-Gómez-De-Liaño
IAIgnacio Almorín-Fernández-Vigo
Ignacio Almorín-Fernández-Vigo
BDBeatriz De-Pablo-Gómez-De-Liaño
Beatriz De-Pablo-Gómez-De-Liaño
AMAna Macarro Merino
Ana Macarro Merino
José Ignacio Fernández-VigoJosé Ignacio Fernández-Vigo
José Ignacio Fernández-Vigo
The Lens Dysfunction Syndrome includes two widespread ocular disorders: presbyopia and cataract. Understanding its etiology, onset, progression, impact, prevention, and treatment remains a significant scientific challenge. The lens is a fundamental structure of the ocular dioptric system that allows for focus adjustment or accommodation to view objects at different distances. Its opacification, primarily related to aging, leads to the development of cataracts. Traditionally, lens alterations have been diagnosed using a slit lamp and later with devices based on the Scheimpflug camera. However, both methods have significant limitations. In recent years, optical coherence tomography (OCT) has become a valuable tool for assessing the lens and pseudophakic intraocular lenses (IOLs) in clinical practice, providing a highly detailed non-invasive evaluation of these structures. Its clinical utility has been described in assessing the shape, location or position, and size of the lens, as well as in determining the degree and type of cataract and its various components. Regarding pseudophakic IOLs, OCT allows for the accurate assessment of their position and centering, as well as for detecting possible complications, including the presence of glistening or IOL opacification. Furthermore, OCT enables the evaluation of the posterior capsule and its associated pathologies, including late capsular distension syndrome. This review highlights the key applications of OCT in the assessment of the lens and pseudophakic IOLs.


25 November 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
IAIgnacio Almorín-Fernández-Vigo
Ignacio Almorín-Fernández-Vigo
SCSilvia Pagán Carrasco
Silvia Pagán Carrasco
IGInes Sanchez Guillen
Ines Sanchez Guillen
José Ignacio Fernández-VigoJosé Ignacio Fernández-Vigo
José Ignacio Fernández-Vigo
AMAna Macarro Merino
Ana Macarro Merino
José Ignacio Fernández-VigoJosé Ignacio Fernández-Vigo
José Ignacio Fernández-Vigo
Background/Objectives: To determine the impact of corneal and biometry parameters on the normative root mean square (RMS) values of corneal aberrations measured at a 6 mm diameter. Methods: The RMS values for corneal aberrations (anterior, posterior, and total) were measured along with corneal parameters using Scheimpflug tomography on 770 normal subjects. The biometric parameters were measured with an optical biometer. A multiple linear regression model was used to assess the effect of these parameters on the RMS values for corneal aberrations. Results: The mean RMS values for low-order (LOAs) and high-order 6 mm aberrations (HOAs) were 1.883 ± 0.797 µm and 0.484 ± 0.173 µm, respectively, and for the anterior and posterior cornea, the values were 0.775 ± 0.166 µm and 0.189 ± 0.036 µm, respectively. For the anterior cornea, the main predictors of the RMS LOAs (R2 = 69.8%) were anterior corneal astigmatism (ACA) and anterior corneal elevation (Ele F) on the apex (both p < 0.0001) and for the RMS HOAs (R2 = 33.3%) the main predictors were age, ACA, and Ele F on the thinnest point (all p < 0.0001). For the posterior cornea, considering only the posterior corneal variables, the main predictors of the RMS LOAs (R2 = 63.4%) were posterior corneal astigmatism and posterior corneal elevation (Ele B) on the thinnest point and apex (all p < 0.0001) and for the RMS HOAs (R2 = 46%) the main predictors were the mean posterior keratometry and Ele B on the thinnest point and apex (all p < 0.0001). Conclusions: Normative data of RMS values for corneal aberrations measured over 6 mm are influenced by age and several corneal parameters, which should be considered when evaluating the diagnostic ability of the RMS values.