Ines Sanchez Guillen

Dr. Ines Sanchez Guillen

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 August 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
José Ignacio Fernández-VigoJosé Ignacio Fernández-Vigo
José Ignacio Fernández-Vigo
Alfonso C. MarcosAlfonso C. Marcos
Alfonso C. Marcos
RARafael Agujetas
Rafael Agujetas
JMJosé María Montanero
José María Montanero
IGInes Sanchez Guillen
Ines Sanchez Guillen
AMAna Macarro-Merino
Ana Macarro-Merino
To compare aqueous humour (AH) dynamics in the presence of a precrystalline (Implantable Collamer Lens®; ICL) or iris-fixed (Artiflex®) phakic intraocular lens (PIOL). By computational fluid dynamics simulation, AH flow was modelled through a peripheral iridotomy (PI) or central lens hole (both 360 μm) in the presence of an Artiflex or ICL lens, respectively. The impacts of AH flow were then determined in terms of wall shear stress (WSS) produced on the endothelium or crystalline lens. Effects were also modelled for different scenarios of pupil diameter (PD 3.5 or 5.5 mm), ICL vault (100, 350, 800 μm) and number of Artiflex iridotomies (1 or 2) and location (12 or 6 o’clock). For a PD of 3.5 mm, AH volumes flowing from the posterior to the anterior chamber were 37.6% of total flow through the lens hole (ICL) and 84.2% through PI (Artiflex). For an enlarged PD (5.5 mm), corresponding values were 10.3% and 81.9% respectively, so PI constitutes a very efficient way of evacuating AH. Central endothelial WSS in Pa was lower for the large vault ICL and the Artiflex (1−03 and 1.1−03 respectively) compared to the PIOL-free eye (1.6−03). Crystalline lens WSS was highest for the lowest vault ICL (1−04). AH flow varied according to the presence of a precrystalline or iris-fixed intraocular lens. Endothelial WSS was lower for an implanted ICL with large vault and Artiflex than in the PIOL-free eye, while highest crystalline WSS was recorded for the lowest vault ICL.

1 October 2018 in International Ophthalmology
Verified
Journal Article
Closed access
PDF file
IAIgnacio Almorín-Fernández-Vigo
Ignacio Almorín-Fernández-Vigo
IGInes Sanchez Guillen
Ines Sanchez Guillen
AMAna Macarro-Merino
Ana Macarro-Merino
BKBachar Kudsieh
Bachar Kudsieh
CFCristina Fernández-Vigo
Cristina Fernández-Vigo
JFJosé A. Fernández-Vigo
José A. Fernández-Vigo

17 March 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
José Ignacio Fernández-VigoJosé Ignacio Fernández-Vigo
José Ignacio Fernández-Vigo
Bárbara Burgos-BlascoBárbara Burgos-Blasco
Bárbara Burgos-Blasco
LDLucía De-Pablo-Gómez-De-Liaño
Lucía De-Pablo-Gómez-De-Liaño
IGInes Sanchez Guillen
Ines Sanchez Guillen
VAVirginia Albitre-Barca
Virginia Albitre-Barca
AMAna Macarro Merino
Ana Macarro Merino
Purpose: To propose a classification of the glistening in intraocular lenses (IOL) using swept-source optical coherence tomography (SS-OCT) by means of a simple, objective and reproducible method that allows the quantification of the presence and severity of glistening. Methods: A cross-sectional study on a sample of 150 eyes of 150 patients who underwent cataract surgery in at least 600 days before the exam and attended a routine examination. Each subject was examined by SS-OCT after pupil dilation, identifying the presence of glistening or hyperreflective foci (HRF) in the central area of the IOL. The degree of glistening was classified into four categories: 0: ≤5 HRF; 1: 6 to 15 HRF; 2: 16 to 30 HRF; and 3: >30 HRF. The intra and interobserver reproducibility (intraclass correlation coefficient, ICC) in the quantification and classification of the glistening were calculated. The correlation between the horizontal and vertical scan of the IOL was also assessed. Results: Glistening was present in the IOL in 42.7% of the patients. The mean number of HRF or glistening microvacuoles was 10.4 ± 26.2 (range 0 to 239). In total, 63.3% of the IOLs had a grade 0, 20% grade a 1, 6.7% grade a 2 and 10% a grade 3. The intraobserver and interobserver reproducibility were very high, both for the absolute quantification of the glistening (ICC ≥ 0.994) and for the severity scale (ICC ≥ 0.967). There was an excellent correlation in the quantification of the IOL glistening between the horizontal and vertical scans (R ≥ 0.834; p < 0.001). Conclusions: The use of SS-OCT makes it possible to identify, quantify and classify IOL glistening in a simple, objective and reproducible way. This technique could provide relevant information for the study of the glistening on IOLs.

1 June 2020 in Archivos de la Sociedad Española de Oftalmología
Verified
Journal Article
Closed access
IGInes Sanchez Guillen
Ines Sanchez Guillen
IAI. Almorín-Fernández-Vigo
I. Almorín-Fernández-Vigo
JFJ.I. Fernández-Vigo
J.I. Fernández-Vigo
LDL. De-Pablo-Gómez-De-Liaño
L. De-Pablo-Gómez-De-Liaño
BKB. Kudsieh
B. Kudsieh
JFJ.A. Fernández-Vigo
J.A. Fernández-Vigo


25 November 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
IAIgnacio Almorín-Fernández-Vigo
Ignacio Almorín-Fernández-Vigo
SCSilvia Pagán Carrasco
Silvia Pagán Carrasco
IGInes Sanchez Guillen
Ines Sanchez Guillen
José Ignacio Fernández-VigoJosé Ignacio Fernández-Vigo
José Ignacio Fernández-Vigo
AMAna Macarro Merino
Ana Macarro Merino
José Ignacio Fernández-VigoJosé Ignacio Fernández-Vigo
José Ignacio Fernández-Vigo
Background/Objectives: To determine the impact of corneal and biometry parameters on the normative root mean square (RMS) values of corneal aberrations measured at a 6 mm diameter. Methods: The RMS values for corneal aberrations (anterior, posterior, and total) were measured along with corneal parameters using Scheimpflug tomography on 770 normal subjects. The biometric parameters were measured with an optical biometer. A multiple linear regression model was used to assess the effect of these parameters on the RMS values for corneal aberrations. Results: The mean RMS values for low-order (LOAs) and high-order 6 mm aberrations (HOAs) were 1.883 ± 0.797 µm and 0.484 ± 0.173 µm, respectively, and for the anterior and posterior cornea, the values were 0.775 ± 0.166 µm and 0.189 ± 0.036 µm, respectively. For the anterior cornea, the main predictors of the RMS LOAs (R2 = 69.8%) were anterior corneal astigmatism (ACA) and anterior corneal elevation (Ele F) on the apex (both p < 0.0001) and for the RMS HOAs (R2 = 33.3%) the main predictors were age, ACA, and Ele F on the thinnest point (all p < 0.0001). For the posterior cornea, considering only the posterior corneal variables, the main predictors of the RMS LOAs (R2 = 63.4%) were posterior corneal astigmatism and posterior corneal elevation (Ele B) on the thinnest point and apex (all p < 0.0001) and for the RMS HOAs (R2 = 46%) the main predictors were the mean posterior keratometry and Ele B on the thinnest point and apex (all p < 0.0001). Conclusions: Normative data of RMS values for corneal aberrations measured over 6 mm are influenced by age and several corneal parameters, which should be considered when evaluating the diagnostic ability of the RMS values.