Tomasz Gedrange

Prof. Tomasz Gedrange


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZKZuzanna Kubiak-Mihkelsoo
Zuzanna Kubiak-Mihkelsoo
AKAgnieszka Kostrzębska
Agnieszka Kostrzębska
BBBłaszczyszyn Błaszczyszyn
Błaszczyszyn Błaszczyszyn
APArtur Pitułaj
Artur Pitułaj
Marzena DominiakMarzena Dominiak
Marzena Dominiak
JHJakub Hadzik
Jakub Hadzik
Autogenous grafts remain the “gold standard” in bone tissue grafting procedures; however, limitations such as donor site morbidity, invasiveness, and limited availability have spurred research into alternative materials. Hydroxyapatite (HA), a widely used bioceramic, is known for its bioactivity and biocompatibility. Nonetheless, its inherent brittleness and porosity necessitate modifications to enhance its mechanical and functional properties. Ionic doping has emerged as a transformative strategy to improve the properties of HA by integrating ions such as strontium (Sr2+), magnesium (Mg2+), and zinc (Zn2+). These dopants influence HA’s crystal structure, morphology, and solubility, resulting in enhanced bioactivity, accelerated bone mineralization, and improved mechanical properties, such as increased fracture resistance and wear durability. Additionally, antimicrobial properties can be achieved through the inclusion of silver ions (Ag+), reducing the risk of peri-implant infections. This review focuses on the effects of ionic doping on the structure and functionality of hydroxyapatite, emphasizing advancements in tailoring its properties to clinical needs. By consolidating two decades of research, this study highlights how ionic doping bridges the gap between synthetic biomaterials and native bone, unlocking new potential in regenerative medicine and orthopedic applications.

Verified
Journal Article
Open access
PDF file
MCMichał Piotr Ciszyński
Michał Piotr Ciszyński
SDSebastian Dominiak
Sebastian Dominiak
Marzena DominiakMarzena Dominiak
Marzena Dominiak
TGTomasz Gedrange
Tomasz Gedrange
JHJakub Hadzik
Jakub Hadzik
In an effort to prepare non-autologous bone graft or biomaterial that would possess characteristics comparable to autologous bone, many different allogenic bone derivatives have been created. Although different existing processing methods aim to achieve the very same results, the specific parameters applied during different stages material preparation can result in significant differences in the material’s mechanical and biological properties The properties, including osteoconductive, osteoinductive, and even osteogenic potential, can differ vastly depending on particular preparation and storage techniques used. Osteogenic properties, which have long been thought to be characteristic to autogenic bone grafts only, now seem to also be achievable in allogenic materials due to the possibility to seed the host’s stem cells on a graft before its implantation. In this article, we aim to review the available literature on allogenic bone and its derivatives as well as the influence of different preparation methods on its performance.

Verified
Journal Article
Open access
PDF file
Jacek MatysJacek Matys
Jacek Matys
JKJulia Kensy
Julia Kensy
TGTomasz Gedrange
Tomasz Gedrange
IZIreneusz Zawiślak
Ireneusz Zawiślak
Kinga Grzech-LeśniakKinga Grzech-Leśniak
Kinga Grzech-Leśniak
Maciej DobrzyńskiMaciej Dobrzyński
Maciej Dobrzyński
Molecular methods have become integral to microbiological research for microbial identification. This literature review focuses on the application of molecular methods in examining airborne bacteria and fungi in healthcare facilities. In January 2024, a comprehensive electronic search was carried out in esteemed databases including PubMed, Web of Science, and Scopus, employing carefully selected keywords such as ((bacteria) OR (virus) OR (fungi)) AND (aerosol) AND ((hospital) OR (healthcare) OR (dental office)) AND ((molecular) OR (PCR) OR (NGS) OR (RNA) OR (DNA) OR (metagenomic) OR (microarray)), following the PRISMA protocol. The review specifically targets healthcare environments with elevated concentrations of pathogenic bacteria. A total of 487 articles were initially identified, but only 13 met the inclusion criteria and were included in the review. The study disclosed that the prevalent molecular methodology for appraising aerosol quality encompassed the utilization of the PCR method, incorporating either 16S rRNA (bacteria) or 18S rRNA (fungi) amplification techniques. Notably, five diverse molecular techniques, specifically PFGE, DGGE, SBT, LAMP, and DNA hybridization methods, were implemented in five distinct studies. These molecular tests exhibited superior capabilities compared to traditional bacterial and fungal cultures, providing precise strain identification. Additionally, the molecular methods allowed the detection of gene sequences associated with antibiotic resistance. In conclusion, molecular testing offers significant advantages over classical microbiological culture, providing more comprehensive information.

Verified
Journal Article
Open access
PDF file
JHJakub Hadzik
Jakub Hadzik
PKPaweł Kubasiewicz-Ross
Paweł Kubasiewicz-Ross
Tomasz Ludwik GębarowskiTomasz Ludwik Gębarowski
Tomasz Ludwik Gębarowski
NWNatalia Waloszczyk
Natalia Waloszczyk
MAMaciej Artur
Maciej Artur
Wojciech SimkaWojciech Simka
Wojciech Simka
The characteristics such as microtopography, physical and chemical properties influence the behavior of an implant in a soft tissue. Anodization—as a potent method of titanium alloy surface modification—of the transgingival abutment or healing screw, has achieved some improvement. One of the possible surface treatment method is low-pressure radiofrequency oxygen plasma treatment. The aim of the study was to evaluate the chemical properties and cytocompatibility of the experimental surface. Titanium discs made of grade-23 titanium alloy (Ti-6Al-4V) anodized (A sample) with different voltage parameters (28, 67, 78, and 98 V) were included in the study. Half of the samples regarded as the “S” group were additionally treated with low-pressure radiofrequency oxygen plasma treatment. The surfaces were characterized using scanning electron microscopy, X-ray spectroscopy and Raman spectroscopy, and electrochemically investigated via a corrosion test. Furthermore, two cell lines were used, including the CHO-compatible reference line and a primary human fibroblast line for the MTT assay; direct (contact) cytotoxicity of the materials was tested with the cells, and the growth of fibroblasts on the surfaces of the different materials was tested. The morphology of the “S”-treated samples did not differ from the morphology of only-anodized samples. However, the oxygen concentration on the surface in that group slightly increased by about 1% as a result of post-trial treatment. The highest corrosion resistance was observed for both A-78 V and S-78 V samples. The cytotoxicity assay revealed no changes in cell morphology or vitality. The MTT test proved comparable culture viability among all groups; however, the “S” samples showed statistically significantly higher fibroblast proliferation and adhesion scores compared to the “A” samples. Through the in vitro study, the low-pressure radiofrequency oxygen plasma treatment of the anodized Ti-6Al-4V alloy presented itself as an auspicious option in the field of transgingival element surface modification of implants.

Verified
Journal Article
Open access
PDF file
Jacek MatysJacek Matys
Jacek Matys
TGTomasz Gedrange
Tomasz Gedrange
Marzena DominiakMarzena Dominiak
Marzena Dominiak
Kinga Grzech-LeśniakKinga Grzech-Leśniak
Kinga Grzech-Leśniak
Background: Effective removal of aerosols generated during dental treatment is crucial for maintaining biosafety in dental practice. This study aimed to measure the aerosol amount and the number of aerobic bacteria in the air during caries treatment. Methods: The study involved 50 molar teeth (n = 50) in the mandible in 50 patients divided into two groups based on the type of a high-volume evacuator (HVE); G1 (n = 25) conventional HVE (EM19 EVO, Monoart® Euronda, Vicenza, Italy) and G2 (n = 25) a new, wider, customized HVE. The PC200 laser particle counter (Trotec GmbH, Schwerin, Germany) was used to measure aerosol particles in a range of 0.3–10.0 μm near the operator’s mouth. The study used 60 microbiological plates with a microbiological medium (Columbia Agar with 5% Sheep Blood) to check the number of aerobic bacteria in the air. Results: The mean value of aerosol particles in the G1 group (conventional HVE) was 54,145 ± 7915, while in the G2 group (test, wider evacuator) was lower and amounted to 32,632 ± 1803. (p < 0.001). The median total bacteria count in the air per cubic meter in control, G1 (HVE), and G2 (NEW-HVE) groups were 50 [36-60]; 772 [643-881]; 120 [92-139], respectively. (p < 0.05). Gram-positive cocci were the predominant bacteria in the plates: Micrococcus sp. (50%), Bacillus species (36.4%), Staphylococcus epidermidis (3.8%), Staphylococcus saprophyticus (3.8%). Conclusions: the application of the wider high-volume evacuator increases the air purity during caries treatment as well as the biological safety of a dental office.

28 August 2024 in Biomedicines
Verified
Journal Article
Open access
PDF file
JFJana Flatten
Jana Flatten
TGTomasz Gedrange
Tomasz Gedrange
CBChristoph P Bourauel
Christoph P Bourauel
LKLudger Keilig
Ludger Keilig
AKAnna Konermann
Anna Konermann
Aims: This study was conducted to systematically evaluate the biomechanical impact of varying degrees of root and bone resorption resulting from periodontitis and orthodontic tooth movement (OTM) on the mandibular anterior teeth. The objective was to determine whether these distinct resorption patterns exert a specific influence on tooth displacement and strain patterns. Methods: A finite element (FE) model of an idealized anterior mandible from the first premolar in the third to the fourth quadrant was developed without bone or root resorption and a constant periodontal ligament (PDL) thickness of 0.2 mm. Variations included three root resorption levels (0%, 20%, 50%) and three bone resorption types (circular 50%, circular 80%, vestibular 80%). Models ranged from 200,000 to 440,000 elements and 55,000 to 130,000 nodes. Orthodontic forces, namely root torque (5 Nmm), intrusion (0.2 N), and distalization (0.5 N) were applied for subsequent crown displacement and PDL strain analysis. Results: A total of 180 simulations were performed. Simulations showed that displacement was similar across different bone resorption conditions, irrespective of modeled root resorptions. Circumferential bone resorption increased tooth displacement, regardless of root resorption status. Vestibular bone resorption exhibited less increase in tooth displacement. However, when accompanied by root resorption, the combination exacerbated tooth displacement. Strains in the PDL clearly increased with a circumferential bone resorption of 80%. Conclusions: This study highlights the critical role of bone resorption in tooth displacement during OTM, particularly the challenges associated with circumferential resorption. Clinicians must consider both bone and root resorption for personalized medicine treatment of patients with severe periodontitis, in favor of low-force application strategies to optimize outcomes and minimize complications linked to excessive tooth displacement.