Mudrik Alaydrus

Prof. Dr. Mudrik Alaydrus

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 July 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Syah AlamSyah Alam
Syah Alam
ZAHRILADHA ZAKARIAZAHRILADHA ZAKARIA
ZAHRILADHA ZAKARIA
ISIndra Surjati
Indra Surjati
Noor Azwan ShairiNoor Azwan Shairi
Noor Azwan Shairi
MAMudrik Alaydrus
Mudrik Alaydrus
TFTeguh Firmansyah
Teguh Firmansyah
This study proposes a single-port dual-band independent microwave sensor for detecting solid materials. The sensor structure consists of a pair U-shaped resonators connected by a power divider and a microstrip feed line with an impedance of 50 Ohms with two different sensing hotspots. The $1^{\text {st}}$ and $2^{\text {nd}}$ resonators operate at a frequency of 1.200 GHz and 2.100 GHz, respectively. The type of material under test (MUT) is a standard material with a size of 10 mm $\times10$ mm (RO5880, RO4003C, and FR4). The proposed sensor had a very high accuracy compared with both of using permitivitty from datasheet and calibrated frequency from simulation for the $1^{\text {st}}$ and $2^{\text {nd}}$ resonator, respectively. Moreover, the pair of the U-shaped resonators had independent performances and they did not affect each other when the MUT was loaded. Furthermore, it can also operate with single-port measurement, which is a more efficient resource. Finally, the proposed microwave sensor can be a promising solution for detecting different permittivity of solid materials independently with high accuracy for applications such as the food industry, material quality control, and biomedical.

1 June 2018 in Materials Research Express
Verified
Journal Article
Closed access
PDF file
EHErfan Handoko
Erfan Handoko
ISIwan sugihartono
Iwan sugihartono
SBSetia Budi
Setia Budi
BAB S Anggoro
B S Anggoro
AMA M Mangasi
A M Mangasi
MAMudrik Alaydrus
Mudrik Alaydrus

20 October 2023 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
SQSiti Nikmatul Qoidah
Siti Nikmatul Qoidah
SSSt. Ulfawanti Intan Subadra
St. Ulfawanti Intan Subadra
ATAhmad Taufiq
Ahmad Taufiq
NMNandang Mufti
Nandang Mufti
SSSunaryono Sunaryono
Sunaryono Sunaryono
TATahta Amrillah
Tahta Amrillah

30 June 2010 in International Journal on Electrical Engineering and Informatics
Verified
Journal Article
Closed access
JBJakarta Universitas Mercu Buana
Jakarta Universitas Mercu Buana
MAMudrik Alaydrus
Mudrik Alaydrus

10 May 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Syah AlamSyah Alam
Syah Alam
ZAHRILADHA ZAKARIAZAHRILADHA ZAKARIA
ZAHRILADHA ZAKARIA
ISIndra Surjati
Indra Surjati
Noor Azwan ShairiNoor Azwan Shairi
Noor Azwan Shairi
MAMudrik Alaydrus
Mudrik Alaydrus
TFTeguh Firmansyah
Teguh Firmansyah
This paper proposes the integration of microwave sensors (MS) and antenna sensors (AS) for contact and non-contact characterization of solid materials. Integration between MS and AS were determined based on the reflection coefficient (S11) where S11 of ≥ -10 dB was proposed as MS and S 11 of ≤ -10 dB was proposed as AS. The proposed sensor consists of a dual T-Shaped resonator with single port operating at a resonant frequency of f r1 = 1.81 GHz for MS and f r2 = 2.34 GHz for AS using FR-4 substrate with ε r of 4.3, tan δ of 0.0265 and thickness of 1.6 mm. Furthermore, the two resonant frequencies had independent characteristics with different sensing hotspots. MS are proposed for permittivity detection of the Material Under Test (MUT) for contact detection while non-contact detection is proposed by utilizing AS. The procedure for contact detection was carried out by placing the material under test on the surface of the sensor while non-contact detection was carried out by placing the MUT with an air gap between the MUT (d) and the AS was 0.5 - 1.5 mm. The measurement results showed that the average accuracy was 99.30% and 99.31% for the MS and AS for the permittivity range of 1 - 6.15 while the normalized sensitivities of the proposed sensors were 1.15 % and 0.16%, respectively. The results of this research are novel and can be recommended for several purposes related to biomedical and pharmaceutical industries requiring contact and non-contact detection of material characterization.

23 August 2017 in Microwave and Optical Technology Letters
Verified
Journal Article
Closed access
PDF file
TFTeguh Firmansyah
Teguh Firmansyah
SPSupriyanto Praptodinoyo
Supriyanto Praptodinoyo
RWRomi Wiryadinata
Romi Wiryadinata
SSSuhendar Suhendar
Suhendar Suhendar
SWSiswo Wardoyo
Siswo Wardoyo
GWGunawan Wibisono
Gunawan Wibisono