Gemma Pelargonio

Dr. Gemma Pelargonio

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2020 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
LSLuca Segreti
Luca Segreti
ASAntonio De Simone
Antonio De Simone
VSVincenzo Schillaci
Vincenzo Schillaci
MBMaria Grazia Bongiorni
Maria Grazia Bongiorni
GPGemma Pelargonio
Gemma Pelargonio
FSFrancesco Solimene
Francesco Solimene

12 January 2021 in Medicina
Verified
Journal Article
Open access
PDF file
FSFabrizio Sollazzo
Fabrizio Sollazzo
VPVincenzo Palmieri
Vincenzo Palmieri
SGSalvatore Francesco Gervasi
Salvatore Francesco Gervasi
FCFrancesco Cuccaro
Francesco Cuccaro
GMGloria Modica
Gloria Modica
MBMassimiliano Bianco
Massimiliano Bianco
Background and objectives: An Italian nationwide pre-participation screening approach for prevention of sudden cardiac death in athletes (SCD-A) in competitive sportspeople showed promising results but did not achieve international consensus, due to cost-effectiveness and the shortfall of a monitoring plan. From this perspective, we tried to provide an epidemiological update of SCD-A in Italy through a year-long internet-based search. Materials and Methods: One year-long Google search was performed using mandatory and non-mandatory keywords. Data were collected according to prevalent SCD-A definition and matched with sport-related figures from Italian National Institute of Statistics (ISTAT) and Italian National Olympic Committee (CONI). Results: Ninety-eight cases of SCD-A in 2019 were identified (48.0% competitive, 52.0% non-competitive athletes). Male/female ratio was 13:1. The most common sports were soccer (33.7%), athletics (15.3%) and fitness (13.3%). A conclusive diagnosis was achieved only in 37 cases (33 of cardiac origin), with the leading diagnosis being coronary artery disease in 27 and a notably higher occurrence among master athletes. Combining these findings with ISTAT and CONI data, the SCD-A incidence rate in the whole Italian sport population was found to be 0.47/100,000 persons per year (1.00/100,000 in the competitive and 0.32/100,000 in the non-competitive population). The relative risk of SCD-A is 3.1 (CI 2.1–4.7; p < 0.0001) for competitive compared to non-competitive athletes; 9.9 for male (CI 4.6–21.4; p < 0.0001) with respect to female. Conclusions: We provided an updated incidence rate of SCD-A in both competitive and non-competitive sport in Italy. A higher risk of SCD-A among competitive and male athletes was confirmed, thus corroborating the value of Italian pre-participation screening in this population.

1 January 2005 in EP Europace
Verified
Journal Article
Open access
PDF file
GDG Demartino
G Demartino
LMLoredana Messano
Loredana Messano
MSMatteo Santamaria
Matteo Santamaria
QPQuintino Parisi
Quintino Parisi
ADA Dellorusso
A Dellorusso
FCFilippo Crea
Filippo Crea
Biventricular implantation procedures require contrast venography of the coronary sinus. The aim of our study was to evaluate the efficacy and safety of contrast venography obtained by direct manual contrast injection into the guiding catheter, compared with venography obtained after occlusion of the coronary sinus by a Swan–Ganz catheter. Eighty-three patients were randomly assigned to direct or occlusive venography technique. The primary endpoint was complication rate. The secondary endpoints were rate of and time required for an adequate venography, total dose of contrast medium and total procedure time. Four dissections of the coronary sinus were observed with the occlusive venography technique group while no complications were observed with the direct venography technique group (p = 0.04). Rate of adequate venography was similar in the two groups (p = NS). The time needed for coronary sinus venography and the total dose of contrast medium was significantly lower in the direct venography technique group compared with the alternative (p < 0.0001 and p = 0.003, respectively); the total procedure time was not significantly different between the two groups (p = NS). The direct venography technique shows a significantly lower incidence of complications and should be considered to be the first line approach to coronary sinus venography during biventricular pacemaker implantation.

28 June 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
EPEnnio C.L. Pisanò
Ennio C.L. Pisanò
VCValeria Calvi
Valeria Calvi
MVMiguel Viscusi
Miguel Viscusi
Antonio RapacciuoloAntonio Rapacciuolo
Antonio Rapacciuolo
LLLudovico Lazzari
Ludovico Lazzari
Giovanni BottoGiovanni Botto
Giovanni Botto
Subclinical atrial fibrillation (AF) is associated with increased risk of progression to clinical AF, stroke, and cardiovascular death. We hypothesized that in pacemaker patients requiring dual-chamber rate-adaptive (DDDR) pacing, closed loop stimulation (CLS) integrated into the circulatory control system through intra-cardiac impedance monitoring would reduce the occurrence of atrial high-rate episodes (AHREs) compared with conventional DDDR pacing. Patients with sinus node dysfunctions (SNDs) and an implanted pacemaker or defibrillator were randomly allocated to dual-chamber CLS (n = 612) or accelerometer-based DDDR pacing (n = 598) and followed for 3 years. The primary endpoint was time to the composite endpoint of the first AHRE lasting ≥6 min, stroke, or transient ischaemic attack (TIA). All AHREs were independently adjudicated using intra-cardiac electrograms. The incidence of the primary endpoint was lower in the CLS arm (50.6%) than in the DDDR arm (55.7%), primarily due to the reduction in AHREs lasting between 6 h and 7 days. Unadjusted site-stratified hazard ratio (HR) for CLS vs. DDDR was 0.84 [95% confidence interval (CI), 0.72–0.99; P = 0.035]. After adjusting for CHA2DS2-VASc score, the HR remained 0.84 (95% CI, 0.71–0.99; P = 0.033). In subgroup analyses of AHRE incidence, the incremental benefit of CLS was greatest in patients without atrioventricular block (HR, 0.77; P = 0.008) and in patients without AF history (HR, 0.73; P = 0.009). The contribution of stroke/TIA to the primary endpoint (1.3%) was low and not statistically different between study arms. Dual-chamber CLS in patients with SND is associated with a significantly lower AHRE incidence than conventional DDDR pacing.

30 December 2024 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Open access
FPFrancesco Perna
Francesco Perna
Francesco FloreFrancesco Flore
Francesco Flore
ATAlessandro Telesca
Alessandro Telesca
EREleonora Ruscio
Eleonora Ruscio
RSRoberto Scacciavillani
Roberto Scacciavillani
GPGemma Pelargonio
Gemma Pelargonio
Introduction: Ultrasound (US)‐guided axillary vein puncture is a safe and effective approach for cardiac implantable electronic device (CIED) implantation, and it is highly recommended by the current consensus document. However, only reports on small populations are available in the current literature regarding the comparison of this technique with other traditional approaches (subclavian vein blind puncture and cephalic vein surgical cutdown).Purpose: We aimed to assess the effectiveness and safety of US‐ guided axillary vein puncture using a microintroducer kit for CIED implantation as compared to the aforementioned traditional approaches.Methods: All consecutive patients with an indication to CIED implantation were prospectively enrolled in our observational study from March 2021 to July 2023. Patients were divided into three groups based on venous access route, according to the operator's preference: cephalic vein surgical cutdown (G1), US‐guided axillary vein puncture (G2), and subclavian vein blind puncture (G3). Clinical and procedural characteristics, success and complication rates were considered for analysis.Results: A total of 1000 patients (65.2% male, mean age 75.5 ± 10.8 years) were enrolled. Cephalic vein surgical cutdown was chosen in 172 (G1, 17.2%), US‐guided axillary access in 433 patients (G2, 43.3%), and subclavian vein in 395 (G3, 39.5%). Success rate was 77.6% in G1, 96.3% in G2, and 97.2% in G3 (G2 vs. G3, p = 0.5; G1 vs. G2, p < 0.0001; G1 vs. G2. vs. G3, p < 0.0001). Compared to subclavian and cephalic groups, in the US‐guided axillary group, a successful access was obtained with a reduced mean number of puncture attempts (G2 vs. G3: 1.3 ± 0.9 vs. 1.8 ± 1, p < 0.0001) and needed reduced times to get access (G2 vs. G3: 15 s [10–30 s] vs. 40 [20–65 s]; p < 0.0001, G1 vs. G2: 210 s [180–247 s] vs. 15 s [10–30 s]; p < 0.0001) and to reach the superior vena cava, without differences in total procedural times (72.9 ± 30.4 vs. 75.7 ± 34.8 min, p = 0.24). Bailout fluoroscopy times [1 (0–8) s vs. 20 (10–58) s, p < 0.0001] and usage of vein angiography (11.9% vs. 51.3%, p < 0.0001) were lower in G2 as compared to G3. Complication rate did not differ among the three study groups (early complications: 2.9% in G1, 2.5% in G2, and 2.5% in G3, p = 0.96; late complications: 2.9% in G1, 1.6% in G2, and 0.8% in G3, p = 0.15).Conclusions: US‐guided axillary vein puncture for CIED implantation using a microintroducer kit is a safe technique with a very high success rate. Compared to other traditional approaches, it allows to get access with a lower number of puncture attempts and with reduced times, without prolonging the total procedural time. Moreover, x‐ray use and need for contrast medium are very rare in US‐guided axillary approach. Hence, it should be considered the strategy of choice for most patients undergoing CIED implantation.

17 May 2023 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
MCMichela Casella
Michela Casella
Sergio ContiSergio Conti
Sergio Conti
Paolo CompagnucciPaolo Compagnucci
Paolo Compagnucci
VRValentina Ribatti
Valentina Ribatti
MNMaria Lucia Narducci
Maria Lucia Narducci
GPGiuseppe Patti
Giuseppe Patti