Assembly and welding of the hemispherical resonator and flat electrode are the core process links in gyro manufacturing, which will affect the electrode excitation, detect gain consistency of the hemispherical resonator gyro and the vibration performance parameters of the resonator, thus ultimately affecting the output accuracy of the gyro. To achieve a high-precision assembly and welding, firstly, this paper establishes the assembly error model of the hemispherical resonator and flat electrode, analyzes the effect of assembly error on static capacitance, and proposes an assembly spacing measurement scheme based on static capacitors. Then, the integrated experimental platform of high-precision assembly and welding is designed and implemented, equipped with a high-precision capacitance detection circuit, and the capacitance detection circuit is calibrated using actuators. Finally, the experimental results show that the average assembly clearance between the hemispherical resonator and the flat electrode reaches 33μm, the peak-to-peak value is less than 3 μm, and the non-uniformity of the assembly gap is less than 9.4%. In addition, to analyze the influence on the vibration parameters of the resonator after assembly and welding, a test platform for measuring the vibration performance parameters of the resonator is built. The experimental results show that the mean reduction of the quality factor of the resonator in the range of 600w~1000w after assembly and welding is less than 8.6%, which verifies the correctness of the theoretical model and the superiority of the assembly and welding scheme.
The hemispherical resonator gyroscope is a gyroscope based on the principle of Coriolis vibration, widely used in inertial measurement systems of spacecraft. This article decomposes the gyroscope into two parts: the resonator shell and the gyroscope head, establishes the energy dissipation mechanism of the gyroscope, and conducts experimental verification. Firstly, based on the working principle of the gyroscope, a mechanical analysis model of the hemispherical resonator gyroscope head with a resonator spherical shell containing quality defects under second-order vibration state was established. The unbalanced force applied by the resonator spherical shell to the hemispherical resonator gyroscope head was analyzed, and the energy transfer path and dissipation mechanism from the spherical shell to the hemispherical resonator gyroscope head were explained. Finally, through the constructed testing platform, the circumferential quality factor test of the hemispherical resonator gyroscope before and after assembly was completed according to the designed experimental plan, and the consistency between theory and experimental phenomena was verified experimentally.
3 March 2025 in IEEE Transactions on Instrumentation and Measurement
This article studies a parameter identification and compensation method to improve the effect of damping asymmetry for the whole-angle mode hemispherical resonator gyro. First, the reason for damping asymmetry is analyzed from the process point of view and a motion equation containing the damping asymmetry is established based on the existing formulas. This sets the foundation for the subsequent analysis and compensation. Second, the equations of gyro drift are derived to clarify the effect of damping asymmetry on the standing wave parameters and key control indicators. The relationship between the output angular rate fluctuation and the damping asymmetry is also obtained. Third, a method of parameter identification and compensation is proposed based on the similarity of the angular rate compensation force and the harmonic components of the amplitude control force. The feasibility of the method is proved in simulation. Finally, the experimental results show that after compensation, the output angular rate fluctuation range is reduced to 29.77% of that before compensation, and the scale factor nonlinearity is dramatically decreased by about 7 times from 103.629 ppm to 15.063 ppm, significantly improving the hemispherical resonator gyro’s performance. Besides, the experiments prove that the effect of mode-matching errors and quadrature errors on the compensation method is extremely limited, verifying the reliability of the method.