In this paper, a novel set-membership state estimation method based on zonotopes is proposed for switched systems subject to unknown-but-bounded disturbance with average dwell time switching. By testing the consistency between the system model and measured output, an intersection zonotope is constructed based on mode-dependent and semi-time-dependent correction matrix. Then, by constructing semi-time-dependent P-radius functions, the issue of L_infinity disturbance attenuation performance for the intersection zonotope is addressed. Finally, a numerical example is presented to illustrate the effectiveness of the proposed approach.
12 October 2022 in IEEE Transactions on Industrial Electronics
In this article, a novel ultrahigh precision mass balancing method for fused quartz hemispherical resonator based on the ion beam etching process is proposed from the perspective of vibration mechanics. First, the motion equations of resonator with mass defect are established to reveal the quantitative relationship between the amplitude of defective mass and frequency split, and the geometrical relationship between the distribution of defective mass and eigenfrequency axis, which is the equivalent morphology of mass defect. Second, according to the motion equations, the radial vibration model of resonator lip edge is deduced, then a new identification model for the vibration parameters composed of the frequency split, mechanical time constant, and azimuth of eigenfrequency axis based on the vibration envelope and spectral analysis is established. The vibration parameters are identified by nonlinear optimization method. After that, the mass removal function and etching efficiency function of ion beam acting on the resonator are calibrated by experimental data, then the etching trajectory is planned and the etching time is calculated. Finally, the experimental result of mass balancing indicates that the frequency split is reduced from 0.2354 to 0.0006 Hz, and the quality factor is greater than 2.2 × 10 7 , which can significantly improve the vibration performance of resonator.
27 January 2022 in IEEE Transactions on Automatic Control
This paper is concerned with the stabilization of continuous-time switched linear neutral systems with tighter bounds on mode-dependent average dwell time. By introducing a novel time-scheduled control strategy, a switching-signal-based multiple discontinuous Lyapunov function (SMDLF) is constructed for continuous-time switched linear neutral systems, where the discontinuous points of the Lyapunov function during each mode-running interval are dynamically adjusted according to the actual system switching signal. First, sufficient criteria are established for global uniform exponential stability (GUES) of switched nonlinear systems. Then, based on the constructed SMDLF, we derive less conservative stability conditions for switched linear neutral systems. Furthermore, a set of time-dependent state feedback controllers are designed to guarantee the GUES of the underlying system. In the end, a simulation example with comparison results is provided to verify the effectiveness and advantages of the presented approach.
14 July 2023 in IEEE Transactions on Instrumentation and Measurement
Assembly and welding of the hemispherical resonator and flat electrode are the core process links in gyro manufacturing, which will affect the electrode excitation, detect gain consistency of the hemispherical resonator gyro and the vibration performance parameters of the resonator, thus ultimately affecting the output accuracy of the gyro. To achieve a high-precision assembly and welding, firstly, this paper establishes the assembly error model of the hemispherical resonator and flat electrode, analyzes the effect of assembly error on static capacitance, and proposes an assembly spacing measurement scheme based on static capacitors. Then, the integrated experimental platform of high-precision assembly and welding is designed and implemented, equipped with a high-precision capacitance detection circuit, and the capacitance detection circuit is calibrated using actuators. Finally, the experimental results show that the average assembly clearance between the hemispherical resonator and the flat electrode reaches 33μm, the peak-to-peak value is less than 3 μm, and the non-uniformity of the assembly gap is less than 9.4%. In addition, to analyze the influence on the vibration parameters of the resonator after assembly and welding, a test platform for measuring the vibration performance parameters of the resonator is built. The experimental results show that the mean reduction of the quality factor of the resonator in the range of 600w~1000w after assembly and welding is less than 8.6%, which verifies the correctness of the theoretical model and the superiority of the assembly and welding scheme.
Due to complicated processing technology, the mass distribution of a hemispherical resonator made of fused silica is not uniform, which can affect the azimuth of the standing wave of a resonator under the linear vibration excitation. Therefore, the analysis of standing wave evolution of a resonator with mass imperfection under linear vibration excitation is of significance for the improvement of the output accuracy of a gyroscope. In this paper, it is assumed that the resonator containing the first–third harmonics of mass imperfection is excited by horizontal and vertical linear vibration, respectively; then, the equations of motion of an imperfect resonator under the second-order vibration mode are established by the elastic thin shell theory and Lagrange mechanics principle. Through error mechanism analysis, it is found that, when the frequency of linear vibration is equal to the natural frequency of resonator, the standing wave is bound in the azimuth of different harmonics of mass imperfection with the change in vibration excitation direction. In other words, there are parasitic components in the azimuth of the standing wave of a resonator under linear vibration excitation, which can cause distortion of the output signal of a gyroscope. On the other hand, according to the standing wave binding phenomenon, the azimuths of the first–third harmonics of mass imperfection of a resonator can also be identified under linear vibration excitation, which can provide a theoretical method for the mass balance of an imperfect resonator.
For a land-vehicle strapdown inertial navigation system (SINS), the problem of initial alignment with large misalignment angle in-motion needs to be solved urgently. This paper proposes an improved ACKF/KF initial alignment method for SINS aided by odometer. The SINS error equation with large misalignment angle is established first in the form of an Euler angle. The odometer/gyroscope dead reckoning (DR) error equation is deduced, which makes the observation equation linear when the position is taken as the observation of the Kalman filter. Then, based on the cubature Kalman filter, the Sage-Husa adaptive filter and the characteristics of the observation equation, an improved ACKF/KF method is proposed, which can accomplish initial alignment well in the case of unknown measurement noise. Computer simulation results show that the performance of the proposed ACKF/KF algorithm is superior to EKF, CKF and AEKF method in accuracy and stability, and the vehicle test validates its advantages.