Filomena Romano

Dr. Filomena Romano

IMAA – CNR (Institute of Methodologies for Environmental Analysis – Italian National Research Council)
orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2018 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
Domenico CiminiDomenico Cimini
Domenico Cimini
PRPhilip Rosenkranz
Philip Rosenkranz
MTMikhail Y. Tretyakov
Mikhail Y. Tretyakov
MKMaksim A. Koshelev
Maksim A. Koshelev
Filomena RomanoFilomena Romano
Filomena Romano
This paper presents a general approach to quantify absorption model uncertainty due to uncertainty in the underlying spectroscopic parameters. The approach is applied to a widely used microwave absorption model (Rosenkranz, 2017) and radiative transfer calculations in the 20–60 GHz range, which are commonly exploited for atmospheric sounding by microwave radiometer (MWR). The approach, however, is not limited to any frequency range, observing geometry, or particular instrument. In the considered frequency range, relevant uncertainties come from water vapor and oxygen spectroscopic parameters. The uncertainty of the following parameters is found to dominate: (for water vapor) self- and foreign-continuum absorption coefficients, line broadening by dry air, line intensity, the temperature-dependence exponent for foreign-continuum absorption, and the line shift-to-broadening ratio; (for oxygen) line intensity, line broadening by dry air, line mixing, the temperature-dependence exponent for broadening, zero-frequency line broadening in air, and the temperature-dependence coefficient for line mixing. The full uncertainty covariance matrix is then computed for the set of spectroscopic parameters with significant impact. The impact of the spectroscopic parameter uncertainty covariance matrix on simulated downwelling microwave brightness temperatures (TB) in the 20–60 GHz range is calculated for six atmospheric climatology conditions. The uncertainty contribution to simulated TB ranges from 0.30 K (subarctic winter) to 0.92 K (tropical) at 22.2 GHz and from 2.73 K (tropical) to 3.31 K (subarctic winter) at 52.28 GHz. The uncertainty contribution is nearly zero at 55–60 GHz frequencies. Finally, the impact of spectroscopic parameter uncertainty on ground-based MWR retrievals of temperature and humidity profiles is discussed.

9 May 2019 in Geoscientific Model Development
Verified
Journal Article
Open access
PDF file
Domenico CiminiDomenico Cimini
Domenico Cimini
JHJames Hocking
James Hocking
FAFrancesco De Angelis
Francesco De Angelis
ACAngela Cersosimo
Angela Cersosimo
Francesco Di PaolaFrancesco Di Paola
Francesco Di Paola
PRPhilip Rosenkranz
Philip Rosenkranz
This paper describes the first official release (v1.0) of RTTOV-gb. RTTOV-gb is a FORTRAN 90 code developed by adapting the atmospheric radiative transfer code RTTOV, focused on satellite-observing geometry, to the ground-based observing geometry. RTTOV-gb is designed to simulate ground-based upward-looking microwave radiometer (MWR) observations of atmospheric downwelling natural radiation in the frequency range from 22 to 150 GHz. Given an atmospheric profile of temperature, water vapor, and, optionally, cloud liquid water content, and together with a viewing geometry, RTTOV-gb computes downwelling radiances and brightness temperatures leaving the bottom of the atmosphere in each of the channels of the sensor being simulated. In addition, it provides the sensitivity of observations to the atmospheric thermodynamical state, i.e., the Jacobians. Therefore, RTTOV-gb represents the forward model needed to assimilate ground-based MWR data into numerical weather prediction models, which is currently pursued internationally by several weather services. RTTOV-gb is fully described in a previous paper (De Angelis et al., 2016), while several updates are described here. In particular, two new MWR types and a new parameterization for the atmospheric absorption model have been introduced since the first paper. In addition, estimates of the uncertainty associated with the absorption model and with the fast parameterization are given here. Brightness temperatures (TB) computed with RTTOV-gb v1.0 from radiosonde profiles have been compared with ground-based MWR observations in six channels (23.8, 31.4, 72.5, 82.5, 90.0, and 150.0 GHz). The comparison shows statistics within the expected accuracy. RTTOV-gb is now available to licensed users free of charge from the Numerical Weather Prediction Satellite Application Facility (NWP SAF) website, after registration. Coefficients for four MWR instrument types and two absorption model parameterizations are also freely available from the RTTOV-gb support website.

13 April 2017 in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
Verified
Journal Article
Open access
LBLorenzo Busetto
Lorenzo Busetto
Sven CasteleynSven Casteleyn
Sven Casteleyn
CGCarlos Granell
Carlos Granell
MPMonica Pepe
Monica Pepe
MBMassimo Barbieri
Massimo Barbieri
Mirco BoschettiMirco Boschetti
Mirco Boschetti
The ERMES agromonitoring system for rice cultivations integrates EO data at different resolutions, crop models, and user-provided in situ data in a unified system, which drives two operational downstream services for rice monitoring. The first is aimed at providing information concerning the behavior of the current season at regional/rice district scale, while the second is dedicated to provide farmers with field-scale data useful to support more efficient and environmentally friendly crop practices. In this contribution, we describe the main characteristics of the system, in terms of overall architecture, technological solutions adopted, characteristics of the developed products, and functionalities provided to end users. Peculiarities of the system reside in its ability to cope with the needs of different stakeholders within a common platform, and in a tight integration between EO data processing and information retrieval, crop modeling, in situ data collection, and information dissemination. The ERMES system has been operationally tested in three European rice-producing countries (Italy, Spain, and Greece) during growing seasons 2015 and 2016, providing a great amount of near-real-time information concerning rice crops. Highlights of significant results are provided, with particular focus on real-world applications of ERMES products and services. Although developed with focus on European rice cultivations, solutions implemented in the ERMES system can be, and are already being, adapted to other crops and/or areas of the world, thus making it a valuable testing bed for the development of advanced, integrated agricultural monitoring systems.

1 March 2021 in Journal of Quantitative Spectroscopy and Radiative Transfer
Verified
Journal Article
Closed access
MKM.A. Koshelev
M.A. Koshelev
IVI.N. Vilkov
I.N. Vilkov
DMD.S. Makarov
D.S. Makarov
MTM.YU. Tretyakov
M.YU. Tretyakov
BVB. Vispoel
B. Vispoel
PRPhilip Rosenkranz
Philip Rosenkranz

26 September 2018 in Remote Sensing
Verified
Journal Article
Open access
PDF file
ERElisabetta Ricciardelli
Elisabetta Ricciardelli
Francesco Di PaolaFrancesco Di Paola
Francesco Di Paola
Sabrina GentileSabrina Gentile
Sabrina Gentile
ACAngela Cersosimo
Angela Cersosimo
Domenico CiminiDomenico Cimini
Domenico Cimini
MVMariassunta Viggiano
Mariassunta Viggiano
This study investigates the value of satellite-based observational algorithms in supporting numerical weather prediction (NWP) for improving the alert and monitoring of extreme rainfall events. To this aim, the analysis of the very intense precipitation that affected the city of Livorno on 9 and 10 September 2017 is performed by applying three remote sensing techniques based on satellite observations at infrared/visible and microwave frequencies and by using maps of accumulated rainfall from the weather research and forecasting (WRF) model. The satellite-based observational algorithms are the precipitation evolving technique (PET), the rain class evaluation from infrared and visible observations (RainCEIV) technique and the cloud classification mask coupling of statistical and physics methods (C-MACSP). Moreover, the rain rates estimated by the Italian Weather Radar Network are also considered to get a quantitative evaluation of RainCEIV and PET performance. The statistical assessment shows good skills for both the algorithms (for PET: bias = 1.03, POD = 0.76, FAR = 0.26; for RainCEIV: bias = 1.33, POD = 0.77, FAR = 0.41). In addition, a qualitative comparison among the three technique outputs, rain rate radar maps, and WRF accumulated rainfall maps is also carried out in order to highlight the advantages of the different techniques in providing real-time monitoring, as well as quantitative characterization of rainy areas, especially when rain rate measurements from Weather Radar Network and/or from rain gauges are not available.

1 February 2008 in Bulletin of the American Meteorological Society
Verified
Journal Article
Closed access
JTJ. P. Taylor
J. P. Taylor
WSW. L Smith
W. L Smith
VCV. Cuomo
V. Cuomo
ALA. M. Larar
A. M. Larar
DZD. K. Zhou
D. K. Zhou
GPG. Pisani
G. Pisani
The international experiment called the European Aqua Thermodynamic Experiment (EAQUATE) was held in September 2004 in Italy and the United Kingdom to validate Aqua satellite Atmospheric Infrared Sounder (AIRS) radiance measurements and derived products with certain groundbased and airborne systems useful for validating hyperspectral satellite sounding observations. A range of flights over land and marine surfaces were conducted to coincide with overpasses of the AIRS instrument on the Earth Observing System Aqua platform. Direct radiance evaluation of AIRS using National Polar-Orbiting Operational Environmental Satellite System (NPOESS) Airborne Sounder Testbed-Interferometer (NAST-I) and the Scanning High-Resolution Infrared Sounder has shown excellent agreement. Comparisons of level-2 retrievals of temperature and water vapor from AIRS and NAST-I validated against high-quality lidar and dropsonde data show that the 1-K/l-km and 10%/1-km requirements for temperature and water vapor (respectively) are ge... The international experiment called the European Aqua Thermodynamic Experiment (EAQUATE) was held in September 2004 in Italy and the United Kingdom to validate Aqua satellite Atmospheric Infrared Sounder (AIRS) radiance measurements and derived products with certain groundbased and airborne systems useful for validating hyperspectral satellite sounding observations. A range of flights over land and marine surfaces were conducted to coincide with overpasses of the AIRS instrument on the Earth Observing System Aqua platform. Direct radiance evaluation of AIRS using National Polar-Orbiting Operational Environmental Satellite System (NPOESS) Airborne Sounder Testbed-Interferometer (NAST-I) and the Scanning High-Resolution Infrared Sounder has shown excellent agreement. Comparisons of level-2 retrievals of temperature and water vapor from AIRS and NAST-I validated against high-quality lidar and dropsonde data show that the 1-K/l-km and 10%/1-km requirements for temperature and water vapor (respectively) are ge...