Fracture tests are a necessary means to obtain the fracture properties of concrete, which are crucial material parameters for the fracture analysis of concrete structures. This study aims to fill the gap of insufficient test results on the fracture toughness of widely used ordinary C40~C60 concrete. A three-point bending fracture test was conducted on 28 plain concrete and 6 reinforced concrete single-edge notched beam specimens with various depths of prefabricated notches. The results are reported, including the failure pattern, crack initiation load, peak load, and complete load versus crack mouth opening displacement curves. The cracking load showed significant variation due to differences in notch prefabrication and aggregate distribution, while the peak load decreased nonlinearly with an increase in the notch-to-height ratio. The reinforced concrete beams showed a significantly higher peak load than the plain concrete beams, attributed to the restraint of steel reinforcement, but the measured cracking load was comparable. A compliance versus notch-to-height ratio curve was derived for future applications, such as estimating crack length in crack growth rate tests. Finally, fracture toughness was determined based on the double-K fracture model and the boundary effect model. The average fracture toughness value for C50 concrete from this study was 2.0 , slightly smaller than that of lower-strength concrete, indicating the strength and ductility dependency of concrete fracture toughness. The fracture toughness calculated from the two models is consistent, and both methods employ a closed-form solution and are practical to use. The derived fracture toughness was insensitive to the discrete parameters in the boundary effect model. The insights gained from this study significantly contribute to our understanding of the fracture toughness properties of ordinary structural concrete, highlighting its potential to shape future studies and applications in the field.
The fatigue safety of cable-girder anchorage structures in cable-stayed bridges under long-term service has attracted much attention. For bridges located in seasonally cold regions, the effect of low-temperature environments should be considered when evaluating fatigue performance. Using the Heilongjiang Bridge in China as a case study, a room-temperature fatigue test with a numerical simulation that considers the low-temperature effect on both load effect and fatigue resistance was proposed. A fatigue test with increased testing load amplitude was performed on a 1:3.75 ratio specimen. After 3.2 million loading cycles and using an acoustic emission technique, no fatigue crack was observed in the anchorage structure. The extended finite element method was then adopted to analyze the anchorage zone’s fatigue crack initiation position and propagation path. Finally, based on the fatigue characteristics of bridge steel, the fatigue resistance to the crack propagation of the vulnerable area was evaluated under three different service conditions. The results show that the fatigue performance of the anchorage zone at low temperatures is sufficient. Moreover, this paper provides a more widely applicable and cost-effective approach for the fatigue evaluation of steel bridges.