The high frequency transformer (HFT) applied in the power electronics operate under the combined stresses of high-frequency PWM voltage and high temperature. The electro-thermal coupling effect can accelerate the aging process and even cause the failure of the HFT's insulation. The accurate modeling and simulation of the multiphysics fields of the HFT is crucial for investigating the electrical and thermal stresses on the insulation. The interaction between the electromagnetic and temperature fields in HFTs makes this task challenging. Specifically, the temperature field in HFTs is influenced by electromagnetic losses, while the electromagnetic parameters of the material and loss distribution are related to temperature and voltage frequency. This paper explores the interaction between high-frequency electromagnetic and temperature fields and develops a comprehensive multiphysics coupling model based on the analyzed results. The model allows for the digital replicate of the circuit, electric, magnetic and temperature fields and it provides precise identification of the electrical and thermal stresses on the insulation. A 60 kHz HFT for dual active bridge (DAB) applications is taken as the example and the simulation results indicate that the proposed model can improve accuracy by 19.14% compared to conventional methods. Finally, a high-frequency pulse width modulation (PWM) test platform for the HFT is developed, and the proposed model is validated through experimental results.
9 December 2024 in IEEE Transactions on Transportation Electrification
Thermo-sensitive electrical parameters (TSEPs) are widely used for estimating the junction temperature of power semiconductors, with the prerequisite that the relationship model between junction temperature and TSEPs is precalibrated. This article proposes an innovative online calibration scheme for power semiconductors in traction inverters, utilizing the inverter dc-link discharge operation mode after system shutdown. It is promising for transportation applications like electric vehicles (EVs) as the required operation mode is intrinsic and frequent. By exploiting the low dynamics in the discharge, the challenges in junction temperature acquisition are addressed and the measurement requirements for TSEPs and associated operation conditions are significantly reduced. The disturbances from parasitic parameters are attenuated as well, enabling calibration accuracy comparable to offline calibration. Compared to existing online calibration schemes, the proposed method outperforms in practicality, complexity, and accuracy, allowing robust calibration in traction applications. The on-state saturation voltage of insulated-gate bipolar transistor (IGBT) devices is used as a typical TSEP for the case study, and proof-of-concept experiments are performed on an automotive traction inverter prototype.
10 December 2025 in IEEE Transactions on Power Electronics
This article presents a health monitoring scheme for dc-link capacitor banks in aerospace motor drives, implemented through the standard postlanding discharge operation of the motor drive. The capacitance percentage of the dc-link capacitor bank relative to its healthy baseline is directly evaluated using solely the dc-link voltage profile without additional hardware upgrades or complex computations, minimizing cost and complexity concerns. Furthermore, to ensure monitoring reliability and effectiveness, practical implementation solutions are provided to address challenges arising from varying operating conditions and unbalanced capacitor degradation within the bank. Compared with existing methods, the proposed scheme offers superior practical deployability and operational robustness. Experimental validation through component-level accelerated aging tests and converter-level discharge tests demonstrates capacitance percentage evaluation error within 0.6%, and reliable detection of critical degradation in individual capacitors within the dc-link capacitor bank under varying operating conditions, enabling proactive maintenance before failure occurs.
6 May 2025 in IEEE Transactions on Power Electronics
As the voltage levels of solid-state transformers (SSTs) increase using medium-voltage switches, high-frequency transformers (HFTs) used inside SSTs are subjected to increased electrical stress. This stress, characterized by high voltage, high-frequency pulsewidth modulation (PWM) voltage, can cause insulation partial discharge (PD) and potentially lead to failure of the HFT insulation system. While PD behavior under power-frequency sinusoidal voltage has been extensively studied, the behavior of HFT insulation under PWM square pulse conditions is less well understood. To address this gap, a high voltage high-frequency PWM voltage PD test platform is developed and high-frequency current transformer (HFCT) and ultra-high-frequency (UHF) antenna are used for PD signal detection. PD tests are performed under a variety of PWM conditions including PWM frequency, rise time, voltage amplitude, and different insulation layers to thoroughly investigate the HFT insulation behavior. The PD characteristics of repetitive PD inception voltage and phase-resolved PD patterns at different PWM conditions are recorded and analyzed under PWM conditions. In addition, this article explores the underlying PD mechanisms of the HFT insulation under high-frequency PWM stress, providing insights to explain the observed test results. The findings from this research provide essential references and lay a solid foundation for future advances in optimal design, health monitoring, reliability analysis, and lifetime prediction for HFTs in power electronics applications.
20 December 2024 in IEEE Transactions on Power Electronics
High-frequency transformers (HFTs) are key devices in solid-state transformers (SSTs). Accurate prediction of the remaining life of the HFT is essential to ensure the reliability of the SST. The insulation of the HFT withstands multistress of high-frequency pulsewidth modulation (PWM) voltage, and high temperature. These severe conditions may lead to its accelerated aging and failure. However, the life characteristics of the HFT insulation subjected to multistress of high voltage, high frequency, and high temperature are not well known introducing a big uncertainty for life prediction and reliability assessment of the HFT, and there is a lack of life model that can be used for HFT insulation considering multistress. This article focuses on the investigation of the interaction between multistress of high voltage, high frequency, and high temperature and it proposes a life model applicable to HFT insulation. A high-frequency PWM voltage electrothermal aging test platform is established, which is capable of generating PWM voltage waveforms up to 10 kV and 100 kHz. The electrothermal aging test is designed and analyzed with the response surface method and analysis of variance. The results revealed a significant effect of switching frequency on the insulation life and non-negligible interactions among the three factors, voltage level, switching frequency, and temperature, at high frequencies. Based on these findings, an electro-thermal-frequency life model for HFT insulation is proposed. Finally, the mechanism of insulation aging and breakdown mechanism at high frequencies is analyzed, and the potential application of the proposed life model is discussed. The outcomes of this research offer valuable references and serve as the foundation for predictive maintenance, insulation system design, and reliability analysis of HFTs under multistress.
22 December 2025 in IEEE Transactions on Power Electronics
This article proposes a converter-level health monitoring method for detecting critical degradation in either dc-link capacitors or power semiconductor modules in traction inverters. The outcome can be used for condition-based maintenance decisions to determine whether the inverter or its power stage as a whole needs to be replaced. The proposed method is based on the dc-link voltage profile during the capacitor discharge operation mode after a traction system is already shut down, which is a standard operation mode for safety reasons. Therefore, the method relies only on existing resources from traction inverters without the need for additional hardware or software. The theoretical foundation of the method and practical considerations for implementation are discussed. Proof-of-concept experiments are performed to validate its effectiveness and feasibility for practical application.