Xing WEI

Mr. Xing WEI


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
BYBo Yao
Bo Yao
XWXing WEI
Xing WEI
Yichi ZhangYichi Zhang
Yichi Zhang
PCPedro Correia
Pedro Correia
RWRUI WU
RUI WU
Huai WangHuai Wang
Huai Wang
Film capacitors for ac filtering play a crucial role in various industrial applications, such as wind power and traction systems. However, current research lacks studies on the aging and failure analyses of high-power ac film capacitors subjected to realistic stresses. This article addresses this gap by presenting degradation testing and failure analysis of metallized film capacitors employed in megawatt (MW) power converters for ac filtering purposes. First, accelerated aging tests are performed on ac filter capacitors based on realistic stresses for more than 3500 h. Testing results on electrothermal parameters are recorded, and derivative models of parameter aging are obtained. The analysis reveals that electrochemical corrosion is the primary aging factor, with negligible capacitance reduction until catastrophic failure occurs. Further investigation, including temperature rise results and microstructure evaluation, indicates that the melting of the dielectric film is a crucial precursor to catastrophic failure. Finally, the possible degradation and failure mechanisms for this type of ac filtering capacitors are summarized. The observations provide a new perspective on the possible failure mechanisms and condition monitoring of film capacitors in ac filtering applications.

1 April 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
XWXing WEI
Xing WEI
BYBo Yao
Bo Yao
YPYingzhou Peng
Yingzhou Peng
YSYongchao Sun
Yongchao Sun
KWKai Wang
Kai Wang
Huai WangHuai Wang
Huai Wang
DC-link capacitor is an important part of traction inverters in electric vehicles (EVs), contributing to cost, size, and failure rate on a considerable scale. This article proposes a noninvasive dc-link capacitance estimation method based on the capacitor discharge profile during the turning- off transition of a traction inverter. The proposed method relies on the existing control and measurement of the traction inverter without the need for software modifications and hardware updates. It minimizes the new risks introduced into the system operation because the estimation procedure is implemented after vehicles are parked. A novel correction solution is proposed to secure the estimation accuracy while also reducing the sampling requirements. Compared with conventional estimation methods, the proposed scheme outperforms in complexity and accuracy. The proof-of-concept experiments based on a scaled-down inverter prototype and a full-scale traction inverter for EV applications verify the feasibility of the proposed method.

9 December 2024 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
XWXing WEI
Xing WEI
BYBo Yao
Bo Yao
ZWZhaoxin Wang
Zhaoxin Wang
YZYi Zhang
Yi Zhang
YPYingzhou Peng
Yingzhou Peng
Huai WangHuai Wang
Huai Wang
Thermo-sensitive electrical parameters (TSEPs) are widely used for estimating the junction temperature of power semiconductors, with the prerequisite that the relationship model between junction temperature and TSEPs is precalibrated. This article proposes an innovative online calibration scheme for power semiconductors in traction inverters, utilizing the inverter dc-link discharge operation mode after system shutdown. It is promising for transportation applications like electric vehicles (EVs) as the required operation mode is intrinsic and frequent. By exploiting the low dynamics in the discharge, the challenges in junction temperature acquisition are addressed and the measurement requirements for TSEPs and associated operation conditions are significantly reduced. The disturbances from parasitic parameters are attenuated as well, enabling calibration accuracy comparable to offline calibration. Compared to existing online calibration schemes, the proposed method outperforms in practicality, complexity, and accuracy, allowing robust calibration in traction applications. The on-state saturation voltage of insulated-gate bipolar transistor (IGBT) devices is used as a typical TSEP for the case study, and proof-of-concept experiments are performed on an automotive traction inverter prototype.

7 February 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JLJiahong Liu
Jiahong Liu
BYBo Yao
Bo Yao
XWXing WEI
Xing WEI
Yichi ZhangYichi Zhang
Yichi Zhang
Huai WangHuai Wang
Huai Wang
This letter proposes a SiC MOSFET gate oxide degradation monitoring method based on the peak value of the bandpass filtered gate voltage during turn-on transitions. The frequency range of the bandpass filter is determined to ensure a proper sensitivity of the detected peak value to the degradation level. The monitoring circuit is presented, including an analog bandpass filter, a peak detector, and a reset pulse generator. Comparing to the existing monitoring schemes, the proposed method is non-invasive and minimizes the interference and new risks to the normal operation of the gate driver. Besides, the proposed monitoring circuit is cost-effective with reduced complexity and less sampling frequency requirement. Multiple high-temperature gate bias (HTGB) tests are performed to accelerate the aging of SiC devices with planar, double trench, and asymmetric trench gate structures. Experimental results from a double pulse tester and a three-phase inverter under dynamic operation verify the effectiveness of the proposed health indicator and the monitoring circuit.

10 December 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
XWXing WEI
Xing WEI
BYBo Yao
Bo Yao
ZWZhaoxin Wang
Zhaoxin Wang
YPYingzhou Peng
Yingzhou Peng
BGBastien Granouillac
Bastien Granouillac
ABAmir Sajjad Bahman
Amir Sajjad Bahman
This article presents a health monitoring scheme for dc-link capacitor banks in aerospace motor drives, implemented through the standard postlanding discharge operation of the motor drive. The capacitance percentage of the dc-link capacitor bank relative to its healthy baseline is directly evaluated using solely the dc-link voltage profile without additional hardware upgrades or complex computations, minimizing cost and complexity concerns. Furthermore, to ensure monitoring reliability and effectiveness, practical implementation solutions are provided to address challenges arising from varying operating conditions and unbalanced capacitor degradation within the bank. Compared with existing methods, the proposed scheme offers superior practical deployability and operational robustness. Experimental validation through component-level accelerated aging tests and converter-level discharge tests demonstrates capacitance percentage evaluation error within 0.6%, and reliable detection of critical degradation in individual capacitors within the dc-link capacitor bank under varying operating conditions, enabling proactive maintenance before failure occurs.

11 July 2025 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
BYBo Yao
Bo Yao
XWXing WEI
Xing WEI
HWHuimin Wang
Huimin Wang
XGXinglai Ge
Xinglai Ge
Haoran WangHaoran Wang
Haoran Wang
Huai WangHuai Wang
Huai Wang
This article proposes a condition monitoring method for the dc-link capacitor in railway traction converter systems with an LC resonant circuit. This method applies to nighttime routine inspection procedures in traction systems with the converter power-off state. Different from the existing methods, the proposed method can monitor the capacitance of the dc link capacitor and the resonant capacitor in the traction converter concurrently. It is based on an ac–dc superimposed signal injection with proper excitation frequency and amplitude and a digital twin method based on the BAT algorithm, which is not interfered by circuit parameters other than those on the dc side. Meanwhile, a hand-held test unit with lightweight features is developed, which can generate the required injection signals and collect the responses of the dc-link filter circuit network. Finally, the proposed monitoring method and the developed test unit are validated by a full-size traction experimental platform. Considering multiple scenarios of dc link capacitor and resonant capacitor aging shows that the monitoring error is less than 0.7% (average) and 1.5% (maximum).