Jessica Bugeja

Dr. Jessica Bugeja

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2022 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
JBJessica Bugeja
Jessica Bugeja
YXYing Xia
Ying Xia
SCShekhar S. Chandra
Shekhar S. Chandra
NMNicholas J. Murphy
Nicholas J. Murphy
JEJillian Eyles
Jillian Eyles
CECraig Engstrom
Craig Engstrom
Original Article Automated volumetric and statistical shape assessment of cam-type morphology of the femoral head-neck region from clinical 3D magnetic resonance images Jessica M. Bugeja, Ying Xia, Shekhar S. Chandra, Nicholas J. Murphy, Jillian Eyles, Libby Spiers, Stuart Crozier, David J. Hunter, Jurgen Fripp, Craig Engstrom

11 October 2023 in Physical and Engineering Sciences in Medicine
Verified
Journal Article
Open access
PDF file
JBJessica Bugeja
Jessica Bugeja
GMGeorges Mehawed
Georges Mehawed
MRMatthew J. Roberts
Matthew J. Roberts
NRNicholas Rukin
Nicholas Rukin
JDJason Dowling
Jason Dowling
RMRebecca Murray
Rebecca Murray
Combined magnetic resonance imaging (MRI) and positron emission tomography/computed tomography (PET/CT) may enhance diagnosis, aid surgical planning and intra-operative orientation for prostate biopsy and radical prostatectomy. Although PET-MRI may provide these benefits, PET-MRI machines are not widely available. Image fusion of Prostate specific membrane antigen PET/CT and MRI acquired separately may be a suitable clinical alternative. This study compares CT-MR registration algorithms for urological prostate cancer care. Paired whole-pelvis MR and CT scan data were used (n = 20). A manual prostate CTV contour was performed independently on each patients MR and CT image. A semi-automated rigid-, automated rigid- and automated non-rigid registration technique was applied to align the MR and CT data. Dice Similarity Index (DSI), 95% Hausdorff distance (95%HD) and average surface distance (ASD) measures were used to assess the closeness of the manual and registered contours. The automated non-rigid approach had a significantly improved performance compared to the automated rigid- and semi-automated rigid-registration, having better average scores and decreased spread for the DSI, 95%HD and ASD (all p < 0.001). Additionally, the automated rigid approach had similar significantly improved performance compared to the semi-automated rigid registration across all accuracy metrics observed (all p < 0.001). Overall, all registration techniques studied here demonstrated sufficient accuracy for exploring their clinical use. While the fully automated non-rigid registration algorithm in the present study provided the most accurate registration, the semi-automated rigid registration is a quick, feasible, and accessible method to perform image registration for prostate cancer care by urologists and radiation oncologists now.

10 August 2023 in Journal of Orthopaedic Research
Verified
Journal Article
Closed access
JBJessica Bugeja
Jessica Bugeja
YXYing Xia
Ying Xia
SCShekhar S. Chandra
Shekhar S. Chandra
NMNicholas J. Murphy
Nicholas J. Murphy
SCStuart Crozier
Stuart Crozier
CECraig Engstrom
Craig Engstrom

8 June 2022 in Arthroscopy, Sports Medicine, and Rehabilitation
Verified
Journal Article
Open access
JBJessica Bugeja
Jessica Bugeja
YXYing Xia
Ying Xia
SCShekhar S. Chandra
Shekhar S. Chandra
NMNicholas J. Murphy
Nicholas J. Murphy
JEJillian Eyles
Jillian Eyles
CECraig Engstrom
Craig Engstrom
Purpose: To obtain automated measurements of cam volume, surface area, and height from baseline (preintervention) and 12‐month magnetic resonance (MR) images acquired from male and female patients allocated to physiotherapy (PT) or arthroscopic surgery (AS) management for femoroacetabular impingement (FAI) in the Australian FASHIoN trial. Methods: An automated segmentation pipeline (CamMorph) was used to obtain cam morphology data from three‐dimensional (3D) MR hip examinations in FAI patients classified with mild, moderate, or major cam volumes. Pairwise comparisons between baseline and 12‐month cam volume, surface area, and height data were performed within the PT and AS patient groups using paired t ‐tests or Wilcoxon signed‐rank tests. Results: A total of 43 patients were included with 15 PT patients (9 males, 6 females) and 28 AS patients (18 males, 10 females) for premanagement and postmanagement cam morphology assessments. Within the PT male and female patient groups, there were no significant differences between baseline and 12‐month mean cam volume (male: 1269 vs 1288 mm 3 , t [16] = −0.39; female: 545 vs 550 mm, 3 t [10] = −0.78), surface area (male: 1525 vs 1491 mm 2 , t [16] = 0.92; female: 885 vs 925 mm, 2 t [10] = −0.78), maximum height (male: 4.36 vs 4.32 mm, t [16] = 0.34; female: 3.05 vs 2.96 mm, t [10] = 1.05) and average height (male: 2.18 vs 2.18 mm, t [16] = 0.22; female: 1.4 vs 1.43 mm, t [10] = −0.38). In contrast, within the AS male and female patient groups, there were significant differences between baseline and 12‐month cam volume (male: 1343 vs 718 mm 3 , W = 0.0; female: 499 vs 240 mm 3 , t [18] = 2.89), surface area (male: 1520 vs 1031 mm 2 , t (34) = 6.48; female: 782 vs 483 mm 2 , t (18) = 3.02), maximum‐height (male: 4.3 vs 3.42 mm, W = 13.5; female: 2.85 vs 2.24 mm, t (18) = 3.04) and average height (male: 2.17 vs 1.52 mm, W = 3.0; female: 1.4 vs 0.94 mm, W = 3.0). In AS patients, 3D bone models provided good visualization of cam bone mass removal postostectomy. Conclusions: Automated measurement of cam morphology from baseline (preintervention) and 12‐month MR images demonstrated that the cam volume, surface area, maximum‐height, and average height were significantly smaller in AS patients following ostectomy, whereas there were no significant differences in these cam measures in PT patients from the Australian FASHIoN study. Level of Evidence: Level II, cohort study.

4 December 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
GMGeorges Mehawed
Georges Mehawed
MRMatthew J Roberts
Matthew J Roberts
JBJessica Bugeja
Jessica Bugeja
JDJason Dowling
Jason Dowling
KSKate Stewart
Kate Stewart
RMRebecca Murray
Rebecca Murray
Introduction: Prostate-specific membrane antigen positron emission tomography/computed tomography (PSMA PET/CT), in combination with magnetic resonance imaging (MRI), may enhance the diagnosis and staging of prostate cancer. Image fusion of separately acquired PET/CT and MRI images serve to facilitate clinical integration and treatment planning. This study aimed to investigate different PSMA PET/CT and MRI image fusion workflows for prostate cancer visualisation. Methods: Eighteen patients with prostate cancer who underwent PSMA PET/CT and MRI prior to radical prostatectomy were retrospectively selected. Alignment of the prostate was performed between PET/CT and MRI via three techniques: semi-automatic rigid, automatic rigid, and automatic non-rigid. Image fusion accuracy was evaluated through boundary and volume agreement, quantified by the Dice Similarity Coefficient (DSC), 95% Hausdorff Distance (HD), and Mean Surface Distance (MSD), with comparison against reconstructed histopathology slices. Results: Image fusion using all techniques resulted in clear lesion visualisation from PSMA PET/CT overlay and anatomical detail afforded by the MRI base and was consistent with histopathology tumour location. Image fusion accuracy was within the recommended range based on a DSC of 0.8–0.9. The automatic non-rigid registration method had the highest volume agreement (DSC: 0.96 ± <0.01) and boundary agreement (HD: 1.17 ± 0.35 mm) when compared to automatic rigid (DSC 0.88 ± 0.02, HD 3.18 ± 0.29 mm) and semi-automatic rigid (DSC 0.80 ± 0.06, HD 5.25 ± 1.68 mm). Conclusions: Image fusion of clinically obtained PET/CT and MRI is feasible and clinically acceptable for use in prostate cancer diagnosis and surgical management. While the best accuracy was observed with the automatic non-rigid technique, which requires further validation, image fusion with clinically accessible methods (semi-automatic rigid) may currently aid patient education, pre-operative planning, and intra-operative guidance.

1 October 2021 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
JBJessica Bugeja
Jessica Bugeja
SCShekhar S. Chandra
Shekhar S. Chandra
ANAleš Neubert
Aleš Neubert
JFJurgen Fripp
Jurgen Fripp
CLCarly A. Lockard
Carly A. Lockard
CECraig Engstrom
Craig Engstrom