Ján Hlina

Dr. Ján Hlina


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2024 in Energies
Verified
Journal Article
Open access
PDF file
JHJán Hlina
Ján Hlina
PMPeter Makýš
Peter Makýš
PŠPatrik Šťastný
Patrik Šťastný
LPLucia Paulovičová
Lucia Paulovičová
This article focuses on the energy performance of buildings with an emphasis on the consequences of non-compliance with technological practices during the building process. We analyse the impact of construction deficiencies on the consumption of heat for heating, focusing on specific case studies of selected building constructions in the Slovak Republic. The results show that non-compliance with prescribed technological standards and procedures leads to significant deterioration in the building’s energy efficiency, which is manifested in increased heat consumption and higher operating costs. The findings of this study have key importance for future construction projects as they offer valuable recommendations for improving energy standards and construction quality, thus contributing to a more sustainable and efficient building process. When designing buildings with near-zero energy demand, it is necessary to eliminate all risks in the project that arise during the preparation and design itself, as well as during implementation.

31 March 2026 in Energies
Verified
Journal Article
Open access
PDF file
JHJán Hlina
Ján Hlina
PMPeter Makýš
Peter Makýš
PŠPatrik Šťastný
Patrik Šťastný
LPLucia Paulovičová
Lucia Paulovičová
Energy performance certification of buildings is a key instrument for assessing energy efficiency within the framework of the Energy Performance of Buildings Directive (EPBD). In practice, significant discrepancies are often observed between the predicted and actual energy performance of buildings. One of the main causes of this discrepancy is non-compliance with technological procedures during construction. This paper analyses the energy and economic consequences of such deviations through a case study of a newly constructed residential building in northern Slovakia that was originally certified in the A0 energy class. The research methodology included in situ inspection of the building, thermographic measurements, destructive probes of the building envelope, analysis of project documentation, and recalculation of energy performance using measured building parameters. The results revealed significant deficiencies in the thermal insulation of the building envelope, roof construction, and window airtightness. After recalculation based on measured parameters, the building’s energy classification deteriorated from A0 to B. The total energy demand increased by 46%, while primary energy demand increased by 141%. The results demonstrate that construction deviations can significantly affect the reliability of energy performance certification. The study highlights the importance of verifying the actual condition of buildings during construction to ensure the reliability of EPC assessments.

20 August 2025 in Buildings
Verified
Journal Article
Open access
PDF file
MŠMilan Švolík
Milan Švolík
PMPeter Makýš
Peter Makýš
PŠPatrik Šťastný
Patrik Šťastný
JHJán Hlina
Ján Hlina
MĎMarek Ďubek
Marek Ďubek
Ensuring the stability of monolithic concrete slabs during construction represents a crucial safety challenge in monolithic reinforced concrete buildings. Theoretical models and structural analyses often assume ideal conditions of supporting props. However, significant deviations occur in practice due to variations in technical condition and installation methods. This study investigates the magnitude of prestressing forces generated in adjustable telescopic steel props depending on manual tightening and hammer blows. Experimental measurements were conducted on different types of props compliant with EN 1065, including both new and worn specimens, to simulate real on-site conditions. The influence of worker body weight was also analyzed. The results confirmed that the technical condition of the prop is the decisive factor affecting the level of prestress. Props in poor condition achieved substantially lower and inconsistent prestressing forces, while new props subjected to five hammer blows reached maximum values up to 13.16 kN. This difference can significantly influence static calculations for slab construction. Contrary to expectations, the influence of worker body weight was not statistically significant; instead, the dominant role was played by installation technique and the accuracy of hammer blows. The findings contribute to the optimization of safety guidelines and the improvement of calculation models for temporary support systems in monolithic construction.