Alla Ivanyshyn

Dr. Alla Ivanyshyn


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2024 in Sensors
Verified
Journal Article
Open access
PDF file
JLJiyun Li
Jiyun Li
HPHongxing Pei
Hongxing Pei
OKOrest Kochan
Orest Kochan
CWChunzhi Wang
Chunzhi Wang
RKRoman Kochan
Roman Kochan
AIAlla Ivanyshyn
Alla Ivanyshyn
This study contributes to improving the accuracy of temperature measurements with a platinum resistance temperature detector (RTD) by proposing techniques to mitigate the error due to self-heating by the operating current. An assessment of the measurement errors of the platinum RTD was carried out to study ways to improve their accuracy. High accuracy can be achieved by individual calibration using a voltage divider circuit to measure resistance, the substitution method, and the transitional measure. It was shown that each of these approaches offers potential improvements in the accuracy of temperature measurements using RTDs. However, one of the genuine limitations is the error due to heating the RTD by the operating current. To address this, both linear and nonlinear methods for correcting the error due to heating by the operating current were studied. This paper examines how these methods can be applied to mitigate the influence of self-heating on measurement accuracy. Moreover, the residual errors associated with these methods of correction were estimated. The analysis showed that while these methods can reduce the errors significantly, there remain limitations below which it is not possible to mitigate the error.

1 January 2023 in Measuring Equipment and Metrology
Verified
Journal Article
Closed access
AIAlla Ivanyshyn
Alla Ivanyshyn
The article compares the international and European requirements for institutions of higher education. General international principles of quality management were also considered and adapted to institutions of higher education. The main requirements for the quality management system (QMS) of a higher education institution (HEI) following international and European standards,) as well as the advantages and main requirements for the implementation of the quality management of educational services, as a tool for managing the processes of providing educational services and improving their quality.

26 September 2023
Verified
Conference Paper
Closed access
AIAlla Ivanyshyn
Alla Ivanyshyn
TZTetiana Zahorodniuk
Tetiana Zahorodniuk
VMValentyna Maliarenko
Valentyna Maliarenko
BSBohdan Sus
Bohdan Sus
SZSergiy Zagorodnyuk
Sergiy Zagorodnyuk
OBOksana Boyko
Oksana Boyko
Application of intelligent expert systems for structuring and automation of laboratory activities in the educational process has been analysed. It is shown that combination of teaching materials with cross-references and transitions by the means of expert systems allows educators to make optimal decisions on time, set priorities and prepare more effective laboratory classes. The implementation of expert systems for classification sections of academic disciplines in both engineering and technical sciences and humanities has been discussed. An algorithm for making decisions by an expert system, where the main emphasis is given to laboratory tasks and work with laboratory equipment, is proposed. It is shown how to develop a new expert system which can help university educators prepare remote laboratory work, and also to use of virtual simulators or effective practical training. The proposed expert systems can be used for classifying thematic sections of a wide range of disciplines, including natural sciences, engineering, and humanities. They can be used for preparing new courses and training new educators in different areas. Thus expert systems are described as high-scale software units without restrictions on the depth of the question tree and the number of logical branches of the classifier.

10 April 2025
Verified
Book Chapter
Open access
PDF file
TBTetiana Bubela
Tetiana Bubela
JMJoanna Michalowska
Joanna Michalowska
NHNataliya Hots
Nataliya Hots
VYVasyl Yatsuk
Vasyl Yatsuk
OSOleh Seheda
Oleh Seheda
AKAleksey Kozinetz
Aleksey Kozinetz
An assessment of the risks of the functioning of cyber-physical systems was carried out. It is proposed to divide them into information risks and metrological risks, since the cyber-physical system is an information and measurement system. Classification features are proposed and risks are structured as an information and measurement system. The Risk Analysis & Management Method (CRAMM) was used to assess the information risks of the cyber-physical systems. According to the results of its use on the example of the cyber-physical soil monitoring system, the levels of vulnerabilities and their weighting effects were identified and calculated, on the basis of which the levels of information risk were calculated. It was established that the highest risk in the studied system is associated with information distortion and failures in the communication network. Corrective actions to reduce them were proposed. The assessment of metrological risks was carried out using the principles of ISO 31000:2018, according to which the probability of occurrence of the event and the severity of the consequences of its occurrence for the soil monitoring system were assessed. For the final formation of the assessment, a matrix of metrological risks was proposed, according to which all metrological risks of the studied system had low and medium levels. It has been established that the methods proposed by the authors can be applied to cyber-physical systems of other purposes.

31 March 2024 in Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Verified
Journal Article
Open access
PDF file
LHLes Hotra
Les Hotra
OBOksana Boyko
Oksana Boyko
IHIgor Helzhynskyy
Igor Helzhynskyy
HBHryhorii Barylo
Hryhorii Barylo
PSPylyp Skoropad
Pylyp Skoropad
OBOlena Basalkevych
Olena Basalkevych
Prolonged exposure to elevated temperatures exceeding 47°C, which can occur during root canal obturation, can cause damage of both dental and bone tissues. In order to study the temperature distribution on the surface of the tooth root a temperature measuring device with cold-junction compensation is proposed. For in vitro measurement of the temperature distribution on the surface of the tooth, 8 thermocouples placed in direct contact with the cementum of the tooth were used. In order to eliminate the cold-junction temperature variations, the temperature equilibration device and RTD were used. The suggested linear approximation for the thermocouples' conversion function provides a nonlinearity relative error of less than 0.05% for K-type thermocouples and 0.07% for J-type thermocouples over the temperature range from 20 to 60°C.

24 November 2025 in Electronics
Verified
Journal Article
Open access
PDF file
BSBohdan Sus
Bohdan Sus
AKAleksey Kozinetz
Aleksey Kozinetz
SLSergii Litvinenko
Sergii Litvinenko
AIAlla Ivanyshyn
Alla Ivanyshyn
TBTetiana Bubela
Tetiana Bubela
Krzysztof PrzystupaKrzysztof Przystupa
Krzysztof Przystupa
A compact LED (light emission diode)-based illumination unit controlled by a microcontroller was developed for recombination-type silicon sensor structures. The system employs an 8 × 8 LED matrix that provides programmable spatial excitation patterns across a 2.2 × 2.2 mm sensor surface. Its operation is based on changes in the silicon surface recombination properties upon analyte interaction, producing photocurrent variations of 10–50 nA depending on the dipole moment. Compared with conventional laser-based systems, the proposed LED illumination significantly reduces cost, complexity, and power consumption while maintaining sufficient optical intensity for reliable photoresponse detection. The embedded controller enables precise timing, synchronization with the photocurrent acquisition unit, and flexible adaptation for various biological fluid analyses. This implementation demonstrates a scalable and cost-efficient alternative to stationary LBIC setups and supports integration into portable or IoT-compatible diagnostic systems. For comparative screening, the LED array was used instead of the focused laser beam typically employed in LBIC (laser beam-induced current) measurements. This paper substantially reduced the peak optical intensity at the sample surface, minimizing local thermal heating critical for enzyme-based or plasma samples sensitive to temperature fluctuations. Photocurrent mapping reveals charge-state modification of recombination centers at the SiOx/Si interface under optical excitation. Further optimization is expected for compact or simplified configurations, particularly those aimed at portable applications and automated physiological monitoring systems.